Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bike Altan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance of AI chatbots in responding to patients’ frequently asked questions about laminate veneer restorations

    by Bike Altan, Şevki Çinar

    Although AI (artificial intelligence) chatbot systems are increasingly used to obtain dental information, limited evidence exists regarding the reliability


  • Open Access

    Effect of different surface conditioning methods and low pH solutions on the shear bond strength of orthodontic brackets to newly introduced CAD/CAM materials

    by Şevki Çınar, Bike Altan Çınar, Gökçe Güneş Bağlan, Ersin Yıldırım


  • Open Access

    Current treatment approaches of newly graduated, intern dentists and dentists in doctoral and specialty training to teeth with excessive substance loss (cross-sectional study)

    by Bike Altan, Mehmet Ali Fi̇lDi̇şİ, Şevki Çinar, Elifnur Aydemi̇r, Davut Özkan

    Aim: New treatment options have been developed as alternative post-retaining restorations and crowns that preserve remaining tooth tissue in endodontically treated teeth with excessive substance loss. This study, current treatment approaches newly graduated, intern and doctoral or specialist dentists in teeth excessive coronal destruction were evaluated. Material and Method: This cross-sectional study, online questionnaire consisting of 22 questions, 3 parts was applied. First part consists of demographic information participants, second part consists of questions measuring awareness about preferred indirect restorations, last part consists of current treatment approaches newly graduated, intern and doctoral or specialist dentists. Total 234 voluntary participants questionnaires were evaluated. Obtained data were analyzed with IBM SPSS V23. Results: In restoration of endodontically treated buccal mesial walls (least 2 mm thick) molars, participants all 3 groups preferred posterior adhesive indirect restorations according to their titles. Considering level of awareness, participants high group preferred posterior adhesive indirect restorations more in restorations endodontically treated buccal lingual walled molar teeth. Participants all 3 groups preferred use fiber under composite strengthen teeth in the restoration of teeth with excessive substance loss. Conclusion: According to the results, it was determined that awareness and knowledge level of dentists who received specialty or doctoral training about new current treatments was higher than other newly graduated and intern dentists. It was observed that participants group with high level awareness mostly preferred posterior region indirect adhesive restorations such as endocrown and onlay.

  • Open Access

    Effects of Two Different Acid Etching and Surface Washing Methods on Bond Strength on Different CAD‐CAM Blocks under Aging Protocols

    by Şevki Çınar, Mehmet Ali Fildişi, Bike Altan, Davut Ozkan

    Aim. The purpose of this study is to investigate the effects of hydrofluoric acid and one‐component ceramic primer and silane (Monobond Etch and Prime (MEP)) applications on lithium disilicate glass ceramics and zirconium‐infiltrated lithium silicate glass ceramics, as well as the effect of ultrasonic and phosphoric acid surface washing methods on bond strength. Materials and Method. A total of 240 ceramic samples were prepared using two different CAD‐CAM material blocks with a thickness of 2 mm made of lithium disilicate glass‐ceramic (IPS e.max CAD) and zirconium‐infiltrated lithium silicate glass ceramic blocks (Celtra Duo). The samples were cemented to the composite discs (Tetric N‐Ceram) after two different acid treatments, and surface washing processes were applied to them. As such, 24 groups were formed, each with two different acid applications, three different washing processes, two different CAD‐CAM blocks, and two different aging procedures (n = 10). Following the application of the acid, different washing processes are used. These were HF acid and washing only (HF + W), HF acid and ultrasonic washing (HF + US), HF acid and phosphoric acid (HF + PA), MEP with washing only (MEP + W), MEP and ultrasonic washing (MEP + US), and MEP and phosphoric acid (MEP + PA). The composite discs were cemented with dual cure adhesive cement (Multilink Automix) after the determined surface treatments were applied to the blocks. After surface applications, SEM analysis was conducted. Following exposure to two different thermal procedures, long‐term (TL) and short‐term (TS), bond strengths were measured using an Instron universal test device. SPSS version 23.0 software was used to perform the statistical analyses. Histogram graphs and the Kolmogorov‐Smirnov/Shapiro‐Wilk test were used to assess the variables’ conformity to the normal distribution. Results. The bond strength values of TS and TL in the Celtra Duo block were significantly higher than those in the e.max CAD block (p < 0.05). The TS‐TL bonding strength value difference in the e.max CAD block was significantly higher than the surface measurements in the Celtra Duo block. While the highest bond strength value HF + US for TS in e.max CAD was 20.07 ± .31, the values of HF + US in Celtra Duo were significantly higher in terms of TL values when compared to other groups. Conclusion. Celtra Duo material demonstrated higher bond strength values after a short and long thermal cycle than e.max CAD material. In general, groups bonded with HF were less affected by the thermal cycle than groups treated with MEP.


  • Open Access

    Evaluation of the marginal fit of finish line designs of novel CAD/CAM restoration materials

    by Bike Altan, Şevki Çinar, Beste Burcu Uz, Davut Özkan

    Aim: The purpose of this study is to compare the marginal fit of crowns manufactured using different CAD/CAM materials on 2 different types of finish line design.Material and Method: Tooth preparations were made by creating 2 different finish lines (rounded shoulder, chamfer) on an acrylic mandibular second premolar model. Impressions were taken on each preparation using polyvinylsiloxane impression material, and blocks with three different compositions including lithium disilicate (LDS), zirconia-reinforced lithium silicate (ZLS), and monolithic zirconia (MZ) (UP.CAD, Celtra Duo, and VITA YZ HT) were produced using a CAD/CAM (computer-aided-design and computer-aided-manufacturing) milling device (VHF R5) (n=10). The marginal gap values of the crown restorations were measured by the same operator using a stereomicroscope (LEICA DVM6). Histogram plots and the Kolmogorov-Smirnov test were used to test the normality of the distributions of the variables. The non-normally distributed (nonparametric) variables were compared using the Mann-Whitney U test for two groups and the Kruskal-Wallis test for more than two groups.Results: The marginal gap values were compared between finish line designs separately for each material. Accordingly, the marginal gap values of the rounded shoulder finish line were smaller than those of the chamfer finish line in all materials. The marginal gap values were also compared among the materials separately for each finish line type. Accordingly, the marginal gap values of the VITA YZ HT (MZ) material were smaller than those of the Celtra Duo (ZLS) and UP.CAD (LDS) materials for both finish line designs. There was no significant difference between Celtra Duo and UP.CAD.Conclusion: The finish line design is a factor that affects marginal fit. Monolithic zirconia is more appropriate for clinical use as it shows a better marginal fit compared to LDS and ZLS.


  • Open Access

    Evaluation of the Prosthodontic Clinical Internship Experiences of 4th and 5th Grade Dentistry Students: A Cross-Sectional Study

    by Bike Altan, Şevki Çinar

    Objective: This study aims to evaluate the prosthodontic internship experiences of 4th and 5th grade dentistry students in terms of clinical procedures and patient-physician relationships. Material and Methods: A questionnaire consisting of a total of 26 closed and open-ended questions was created through Google Forms and shared with students' representatives of each grade. It included 5-point Likert scale to allow dentistry students to evaluate prosthodontic treatment procedures. A total of 143 dentistry students were included in the study. The data were statistically analyzed using the Pearson chi-square test and the Bonferroni-corrected Z-test. Results: Of the dentistry students, 58% were 4th graders, 42% were 5th graders, 63.6% reported to consider themselves sufficient when planning treatment, 50.4% reported to spend around 30 min-1 hour for a tooth preparation, 56.8% reported border moulding as the most challenging complete denture clinical procedure, and 77.5% reported to feel strongly responsible for patients whom they treat. In addition, there was no statistically significant difference between the students' perceptions of whether the treatment they applied was ideal according to their grades (p=0.089). Conclusion: In general, dentistry students have the most difficulty in tooth preparation among fixed prosthesis clinical procedures and in border molding among total prosthesis clinical procedures. The 5th graders were more successful than the 4th graders in some clinical procedures that required correct use of time and dexterity.


  • Open Access

    Detecting Prosthetic Restorations Using Artificial Intelligence on Panoramic Radiographs

    by Bike Altan, H. Gurkan Gunec, Sevki Cinar, Secilay Kutal, Semih Gulum, Kader Cesur Aydin

    Aim. This study applied a CNN (convolutional neural network) algorithm to detect prosthetic restorations on panoramic radiographs and to automatically detect these restorations using deep learning systems. Materials and Methods. This study collected a total of 5126 panoramic radiographs of adult patients. During model training, .bmp, .jpeg, and .png files for images and .txt files containing five different types of information are required for the labels. Herein, 10 of panoramic radiographs were used as a test dataset. Owing to labeling, 2988 crowns and 2969 bridges were formed in the dataset. Results. The mAP and mAR values were obtained when the confidence threshold was set at 0.1. TP, FP, FN, precision, recall, and F1 score values were obtained when the confidence threshold was 0.25. The YOLOv4 model demonstrated that accurate results could be obtained quickly. Bridge results were found to be more successful than crown results. Conclusion. The detection of prosthetic restorations with artificial intelligence on panoramic radiography, which is widely preferred in clinical applications, provides convenience to physicians in terms of diagnosis and time management.


  • Open Access

    Effect of Repeated Firings and Thickness on Optical Properties of Variable Preshaded and Shaded Novel Translucent Zirconia Blocks

    by Bike Altan, Sevki Cinar

    Objective. The purpose of this study was to examine the optical properties of translucent zirconia with different thickness during multiple firings. Materials and Methods. Three different types of translucent zirconia (Vita YZ HT (HT), Vita YZ ST (ST), Vita YZ XT (XT)) with thickness of 0.5, 1, and 1.5 mm were used in the study. 180 disk‐shaped specimens (n = 10) were prepared from preshaded and nonshaded blocks. The coloring liquid (A2, Vita Shade Liquid) was applied with a synthetic nylon brush in the nonshaded group. Then, the specimens were then subjected to 1, 3, and 5 firing times. After consecutive firings, color differences (ΔE) and translucency parameter (TP) were measured. Statistical analysis was carried out by using repeated measure ANOVA followed by Tukey test. Results. ANOVA analysis reveals that TP and ΔE were significantly affected by the repeated firings. The highest TP was seen in 0.5 mm XT specimen. For all specimens, TP decreases from 1st to 3rd firing cycles, despite TP increases from 3rd to 5th firing cycles. Although there is a significant change in TP values in 0.5 mm thickness, there is no significant change between firing cycles for 1 and 1.5 mm thickness specimens. The highest ΔE value was observed for shaded specimens between 1st and 5th firings. ΔE values were not significantly different between 1 and 3 firings. Conclusions. Changes in thickness and repeated firings of zirconia specimens affected final color and translucency of zirconia specimens. HT blocks are more affected by consecutive firings than ST and XT blocks. ΔE increased as the thicknesses decreased for both types of translucent zirconia specimens tested.


  • İmplant Destekli Overdenture Protezlerde Ataşman Seçim Kriterleri Ve Önemi

    by Beste Burcu Uz, Bike Altan, Şevki Çınar

    İmplant destekli protezler implantlar tarafından tutuculuk sağlarken ağızdaki dokulardan destek alırlar. Overdenture protezler, çene ilişkisinin uygun olmadığı ve kemik yıkımının fazla olduğu hastalarda hijyeni sağlamada kolaylık sağlaması, ekonomik olması ve bir yandan da estetiğin sağlanmasına olanak tanıdığı için tercih edilmektedir. Son yıllarda hasta memnuniyetine verilen önem artmış ve bunu sağlamanın yolları geliştirilmeye başlanmıştır. Çoğu vaka değerlendirildiğinde overdenture protezlerin geleneksel protezlere göre daha iyi bir seçenek olduğu görülmüştür. Bunun sebeplerine örnek olarak klinik yapım aşamasının daha kısa olması sayesinde yaşlı hastalarda daha güvenilir bir yol olması, estetik üstünlük, çiğneme fonksiyonunun daha iyi olması ,protez stabilitesinin üstünlüğü ve daha az çiğneme güçlüğünün yaşanması verilebilir. İmplant destekli overdenture protezlerde farklı ataşman sistemleri kullanılmakta olup hekimlerin karar vermekte zorlandığı konuların başında gelmektedir. Seçim yapılırken hastanın ağız hijyenine verdiği önem, implantların arasındaki mesafe, anatomik faktörler, destek sayısı ve kretteki mevcut dağılımı, kretin şekli, kemik yıkım miktarı, tutuculuk ihtiyacı, hastanın psikolojik durumu, beklentileri ve ekonomik durumu dikkate alınmalıdır.

  • Open Access

    Effect of Veneering and Hydrothermal Aging on the Translucency of Newly Introduced Extra Translucent and High Translucent Zirconia with Different Thicknesses

    by Sevki Cinar, Bike Altan

    Purpose. The purpose of this study was to evaluate the effect of veneering and aging on the translucency of newly introduced extra and high translucent zirconia with different thickness. Materials and Methods. One hundred forty disk‐shaped specimens were fabricated from two translucent zirconia blocks (VITA YZ XT and VITA YZ HT), and they are milled with CAD/CAM system. Then, specimens were divided into nonveneered (XT, HT) and veneered groups (XTV, HTV). Nonveneered groups were prepared with four different thicknesses (0.5‐1‐1.5‐2 mm). Veneered groups were divided into three subgroups (n = 10) for veneering with base dentin ceramic with thicknesses of 0.5 + 0.5, 0.5 + 1, and 0.5 + 1.5 mm. A spectrophotometer was used to calculate the translucency parameter (TP) and contrast ratio (CR) of all specimens before and after aging. Statistical analysis was performed using 3‐way ANOVA and Tukey HSD tests (p < 0.05). Results. TP values were significantly affected by thickness of specimens (p < 0.001). VITA YZ XT was significantly found more translucent than VITA YZ HT. The highest translucency was observed in the XT‐0.5 mm group. There is no significant difference between translucency of the veneered and nonveneered groups in the same thickness for XT. On the contrary, veneering significantly affected translucency of HT. TP values significantly decreased after aging for all groups. After aging, translucency value difference before and after aging was the highest in the XT‐0.5 mm group whereas the HTV‐2 mm group showed the lowest difference after aging. TP decreased significantly as thickness of specimen increases regardless of the material type. Extra translucent and nonveneered zirconia groups are more prone to hydrothermal aging. Conclusions. The translucency parameter of zirconia ceramics was significantly influenced by both material type and veneering. Also, extra translucent and nonveneered zirconia groups are more susceptible to hydrothermal aging.