  • Compensation Method for the Carrier Magnetic Interference of Underwater Magnetic Vector Measurement System

    by Supeng Li, Defu Cheng, Yi Wang, Jing Zhao

    This paper proposed a new compensation method of underwater magnetic vector measurement system which innovatively using the geomagnetic total field as benchmark. Moreover, this method does not require the use of heading angle data in the calculation of the compensation parameters, which avoids errors caused by insufficient accuracy of underwater heading angle. The implementation of these features relies on the new objective function constructed according to the characteristics of the spatial projection of the magnetic vector field on the horizontal plane of the geographical coordinate. The core matrix of the geomagnetic vector ellipsoid model is used as a constraint to determine the range of function solutions. The Levenberg-Marquardt algorithm is used to find the optimal solution to the new objective function. Three experiments were carried out to verify the proposed method. In simulation experiment, the deviation between the calculated value and the preset value is less than 0.01%. In field experiment, the standard deviation value of x, y, z magnetic components and the root mean square error of magnetic total field after compensation are reduced from 1527.38nT, 1397.35nT, 1529.16nT, 574.94nT to 9.86nT (0.65%), 9.99nT (0.72%), 5.63nT (0.38%), 2.14nT (0.37%). The proposed method is finally verified by marine experiment. The standard deviation value of x, y, z magnetic components and the root mean square error of magnetic total field after compensation are reduced from 575.02 nT, 830.60 nT, 620.95 nT, 1702.35 nT to 17.43 nT (1.11%), 14.14 nT (1.70%), 25.17nT (4.10%), 7.18 nT (0.42%).


  • Open Access

    Calibration of strapdown magnetic vector measurement systems based on a plane compression method

    by Supeng Li, Defu Cheng, Yi Wang, Jing Zhao

    The strapdown magnetic vector measurement system, which can measure the magnetic vector and the attitude of a magnetometer simultaneously, has wide applications in geophysical prospecting, etc. Calibration of systematic errors, including magnetometer errors and misalignment errors, is essential for this system. Traditional methods calibrate these two errors separately, with the problem of cumbersome steps and being dependent on special data acquisition methods, such as rotation. An original method that combines a plane compression method with an ellipsoid fitting method is proposed in this paper, which can simultaneously complete the calibration calculation of magnetometer error and misalignment error in one experiment. The calculation can be performed using the spatial scatter point data required by the traditional attitude-independent magnetometer calibration method, and no additional mechanical equipment is required. A mathematical analysis of this method is performed to study the elements decreasing the measurement accuracy of the system, and numerical simulation and field experiments are performed to validate the analysis. The results indicate that the method can contribute to the accuracy improvement of magnetic vector measurement systems.


  • Open Access

    An Improved Calibration Method for the Misalignment Error of a Triaxial Magnetometer and Inertial Navigation System in a Three-Component Magnetic Survey System

    by Supeng Li, Defu Cheng, Quanming Gao, Yi Wang, Liangguang Yue, Mingchao Wang, Jing Zhao

    In order to calibrate the misalignment error of a triaxial magnetometer and an inertial navigation system in a three-component magnetic survey system, an improved method with easy realization is proposed in this paper. We establish the misalignment error model based on Euler’s theorem. We transform the calibration of misalignment error into estimating calibration parameters to minimize the value of objective function. Then, the nonlinear least squares method is used to estimate the calibration parameters. In the simulation experiment, the deviation between the value and the preset value is within 1 nT. In the field experiment, the fluctuation value of the x, y, and z components reduce to 1.09%, 0.92%, and 1.28%, respectively. The absolute deviation values are reduced to 0.72%, 0.70%, and 0.81% and the standard deviation value are reduced to 0.74%, 0.71%, 0.86%, respectively. The proposed method has advantages of high operability and precision as compared with existing methods.