TSTobias Schrag

Tobias Schrag

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tobias Schrag has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Economic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks

    by Simon Nikolaus Müller, Jazmine Johanni Binti Puriantoh, David Schmitt, Peter Bayer, Tobias Schrag

    Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.

  • Open Access

    Economic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks

    by Simon Nikolaus Müller, Jazmine Johanni Binti Puriantoh, David Schmitt, Peter Bayer, Tobias Schrag

    Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.

  • Open Access

    Optimal Integration of Seasonal Thermal Energy Storage in a Thermal Source Network

    by Shariq Akbar, Simon Nikolaus Müller, Natalie Peracha, David Schmitt, Abdulrahman Dahash, Christoph Trinkl, Tobias Schrag

    Thermal Source Networks (TSNs) are a key element of future district energy systems, because they enable the integration of locally available diverse renewable and waste-heat sources. Seasonal thermal energy storage (sTES) can enhance TSN flexibility by enabling inter-seasonal energy shifting and mitigating mismatches between supply and demand. This study investigates the optimal integration of a retrofit sTES into a TSN, using the incampus industrial park in Ingolstadt, Germany, as a case study. A dynamic simulation framework is developed by coupling a MATLAB/Simscape TSN model with a physics-based sTES model developed in Modelica/Dymola and exported as Functional Mock-up Unit. A parametric assessment is performed by varying key sTES design parameters (e.g., insulation) and demand characteristics (e.g., demand simultaneity). Performance is evaluated using three indicators: sTES efficiency, heating and cooling demand coverage, and levelized cost of thermal service (LCOTS). Results show that improved insulation and compact geometry increase storage efficiency by 21% and reduce LCOTS by 13%, whereas increasing sTES volume can increase LCOTS by 40%. A heat pump-assisted charging option extends the sTES usable temperature range and increases demand coverage by 16% without substantially increasing thermal losses. In contrast, higher demand simultaneity between heating and cooling reduces sTES utilization and leads to a pronounced increase in LCOTS by 125%. Overall, the analysis identifies a near-Pareto-optimal configuration that balances efficiency, coverage, and cost, and provides practical guidelines for integrating seasonal storage in next-generation low-temperature thermal networks.

  • Assessment of the Seasonal Energy Performance of a Dual-Source Heat Pump Coupled to an Undersized Borefield Using the Hardware-in-the-Loop Approach

    by Christian Natale, Tobias Reum, Matteo Dongellini, Claudia Naldi, David Schmitt, Thorsten Summ, Gian Luca Morini, Tobias Schrag

  • Open Access

    Design, construction, and scientific monitoring of a Reno-sTES

    by Christoph Bott, Emre Bas, Abdulrahman Dahash, Fabrizia Giordano, Janik Trauner, Daniel Lager, Markus Faigl, Christian Schneider, David Hoffmann, Jenny Weise, et al.

    Seasonal thermal energy storage (sTES) is an enabler for matching a temporal imbalance between thermal supply and demand in energy systems. This increases, among others, system efficiency and resilience. By reducing peak loads and fossil supply, sTES further supports decarbonization strategies, making it a cornerstone of long-term, climate-neutral thermal supply strategies. sTES can be realized through artificial systems (i.e., tank (TTES), water-gravel (WGTES), and pit thermal energy storage (PTES)) (Bott et al. 2019). In contrast to geological storage technologies, they store heat or cold in closed volumes separated from the ground. While they can achieve high efficiencies, new installations are often associated with high costs due to excavation, construction, sealing, and insulation. They amount to emissions (Weise et al. 2025), and their performance can be sensitive to thermal losses, groundwater interactions (Bott et al. 2024), and spatial constraints, limiting scalability in dense urban environments.The Reno-sTES (renovated sTES) concept addresses these challenges by reusing idle/decommissioned infrastructure. By integrating thermal storage into existing basins, Reno-sTES significantly reduces construction effort, material use, and economic risks, while improving environmental performance and accelerating time-to-operation. Further advantages include no further land use, soil sealing, and increased public acceptance: Instead of installing new, visually intrusive infrastructure, desolate installations are brought back to life. Typical candidates for Reno-sTES include basins for former (waste-) water treatment, swimming pools, gravel pits, stormwater retention, industrial cooling, or fire-water reservoirs, and abandoned industrial tanks.This study presents the first-time R&D-accompanied implementation of a Reno-sTES system at the incampus, Ingolstadt (Müller et al. 2025). Former water treatment basins of a refinery are being repurposed into a combined, multi-unit WGTES. Our contribution focuses on challenges and solutions during the design and construction/renovation phase, including questions related to handling complex geometries, choosing materials that balance thermal performance and durability, and tailored heat-exchanger designs for effective charging and discharging. Environmental constraints and the need for innovative, new planning/design and construction methods are addressed as well (Dahash et al. 2025). The study summarizes the scientific assessment of these aspects before commissioning, expected in Spring 2026, and includes comprehensive monitoring concepts (e.g. via active distributed temperature sensing) within the basins and surrounding ground. Also on this basis, a successful preparation and construction of this Reno-sTES represents an important contribution to the energy transition and forms the basis for further analyses within the Horizon Europe project INTERSTORES (INTERSTORES 2026).LiteratureBott et al. (2019). State-of-technology review of water-based closed seasonal thermal energy storage systems. Renewable and Sustainable Energy Reviews, 113, 109241.Bott et al. (2024). Influence of thermal energy storage basins on the subsurface and shallow groundwater. Journal of Energy Storage, 92, 112222.Dahash et al. (2025). Simulation-based planning for cost-effective and energy-efficient large-scale seasonal thermal energy storage systems. Renewable Energy, 258, 124813.INTERSTORES 2026. Available online: https://interstores.eu/. Müller et al. (2025). Implementation of an Expanding Thermal Source Network as a Step Towards CO₂-Neutral Industry. Energy, 330, 136766.Weise et al. (2025). Comprehensive life cycle assessment of selected seasonal thermal energy storage systems. Renewable Energy, 124232.

  • Open Access

    Simulation of Re-Used Basin Structures for Long-Term, Large-Scale Sensible Thermal Energy Storage

    by Christoph Bott, Mathias Ehrenwirth, Christoph Trinkl, Tobias Schrag, Peter Bayer

    Heat storages have become an increasingly important component of innovative energy systems on a district-level, characterized by a high share of renewable energy and/or a high degree of autarky. Large-scale thermal energy storages are required to compensate for the seasonal mismatch between demand and supply; they form a central junction in the distribution network of a district, linking the various sources and sinks.Established geothermal heat storage systems (Aquifer/borehole thermal energy storages) already show a high market availability. Based on a large number of customized implementations, substantial expertise and best practice is available in this sector. Additionally, closed systems based on artificial basins (Tank, pit, water-gravel thermal energy storages) were developed for site-independent implementation; they can be distinguished by different components, materials and construction methods. However, they still lack market maturity, with two key aspects as critical barriers: firstly, building complexity of such facilities is high, resulting in high investment costs. Secondly, planning processes are still subject to a significant degree of uncertainty. Consequently, such sophisticated and expensive projects are often contrasted with a high financial and technological risk.In order to tackle both of these key issues, we present two solutions within our study. We introduce an interesting alternative based on recycling. As high investment costs result mainly from excavations and expenses for structural components, we suggest the re-use of existing infrastructures and artificial basin installations. In our presentation, we estimate the potential of these technical conversions. From a conceptual perspective, we demonstrate the variety of possible types of infrastructures and analyze their suitability for being re-used as storage based on different requirements, e.g., accessibility, integrability, competing interests and legal constraints. From this, we derive an overall assessment with regard to the suitability of sites and highlight advantages and weaknesses of the various types of infrastructures.Still, any implementation can only be successful if the structure used shows sufficient performance. This is in high contrast to the usually considerable deviations from common design conventions for closed seasonal thermal energy storages, e.g., geometrically with respect to the surface/volume ratio. Here, the possible maximum storage capacity, charging/discharging power and efficiency of a re-used infrastructure after its conversion needs to be analyzed from a technical perspective. To address this suitability aspect, we use a recently developed simulation tool “STORE”, which allows versatile modelling and evaluation of storage design scenarios on a component level using a 2.5‑D approach. In our presentation, we employ “STORE” to a case study and examine a potential re-use of a former water-treatment basin. After applying common boundary conditions of an energy system and setting different design scenarios, we focus on performance indicators and reveal the best technical solution for this specific case study and discuss transferability of the results.Finally, we use our study to demonstrate, under which conditions the conversion and re-use of artificial infrastructures can be a promising approach: By reducing investment costs of large-scale, closed thermal energy storage systems, it can pave their way to full market availability.