SMSimon Müller

Simon Müller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Simon Müller has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    How Water Quantities Are Calculated in Agrivoltaic Models

    by Rushabh Jain, Simon Müller, Axel Bruck, Daniel Navarro Gevers

    Agrivoltaic systems change the radiation, wind, soil temperature and rainfall that reach a crop. Because each field measurement is tied to one site, the resulting change in water use across designs, crops and climates is usually estimated with models. This review describes how those models calculate water. Scopus and IEEE Xplore were searched for publications from 2011 to the first half of 2026, with complementary searches in August 2026. The review includes 39 studies whose water values are calculated rather than measured, and each reported value was traced back to the equation that produced it. In 24 studies, evaporative demand is calculated from weather and scaled to the crop; in 10, evapotranspiration is obtained as one term of a balance of energy, vapor or soil water; and 5 report a water value without modelling a water process. Because these calculations return different quantities, a reported percentage change in water use may refer to atmospheric demand, crop demand or actual evapotranspiration. The photovoltaic (PV) array can enter the calculation through seven routes: shading, longwave radiation from the panels, wind and surface roughness, soil temperature, stomatal response, air temperature and humidity and rainfall interception. Shading is represented in 33 of the 34 studies that model a water process, and each of the other routes in only one to eight. Three further choices change the reported value: where shading is applied in the calculation, whether soil water stress is included and whether position beneath the array is resolved. Two calculated water values for two similar PV installations are not comparable unless the equation and these three choices match. This review sets out the equations, the points at which a PV array can act on them and the choices behind each reported value, so that a calculation can be chosen for the terms it carries rather than inherited with a parent model. The counts describe this corpus and are conditional on the search strategy. What remains open is how these calculations perform against measurements, above all in dry regions, where water rather than light limits production.

  • Open Access

    Economic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks

    by Simon Nikolaus Müller, Jazmine Johanni Binti Puriantoh, David Schmitt, Peter Bayer, Tobias Schrag

    Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.

  • Open Access

    Economic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks

    by Simon Nikolaus Müller, Jazmine Johanni Binti Puriantoh, David Schmitt, Peter Bayer, Tobias Schrag

    Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.

  • Open Access

    Operating thermal source networks – How supply temperature and ground exchange shape performance

    by Simon Müller, David Schmitt, Christoph Bott, Shariq Akbar, Peter Bayer, Tobias Schrag

  • Open Access

    Optimal Integration of Seasonal Thermal Energy Storage in a Thermal Source Network

    by Shariq Akbar, Simon Nikolaus Müller, Natalie Peracha, David Schmitt, Abdulrahman Dahash, Christoph Trinkl, Tobias Schrag

    Thermal Source Networks (TSNs) are a key element of future district energy systems, because they enable the integration of locally available diverse renewable and waste-heat sources. Seasonal thermal energy storage (sTES) can enhance TSN flexibility by enabling inter-seasonal energy shifting and mitigating mismatches between supply and demand. This study investigates the optimal integration of a retrofit sTES into a TSN, using the incampus industrial park in Ingolstadt, Germany, as a case study. A dynamic simulation framework is developed by coupling a MATLAB/Simscape TSN model with a physics-based sTES model developed in Modelica/Dymola and exported as Functional Mock-up Unit. A parametric assessment is performed by varying key sTES design parameters (e.g., insulation) and demand characteristics (e.g., demand simultaneity). Performance is evaluated using three indicators: sTES efficiency, heating and cooling demand coverage, and levelized cost of thermal service (LCOTS). Results show that improved insulation and compact geometry increase storage efficiency by 21% and reduce LCOTS by 13%, whereas increasing sTES volume can increase LCOTS by 40%. A heat pump-assisted charging option extends the sTES usable temperature range and increases demand coverage by 16% without substantially increasing thermal losses. In contrast, higher demand simultaneity between heating and cooling reduces sTES utilization and leads to a pronounced increase in LCOTS by 125%. Overall, the analysis identifies a near-Pareto-optimal configuration that balances efficiency, coverage, and cost, and provides practical guidelines for integrating seasonal storage in next-generation low-temperature thermal networks.

  • Open Access

    Integrating a Seasonal Thermal Energy Storage FMU in a MATLAB/Simscape Thermal Source Network Model

    by Simon Müller, Abdulrahman Dahash, Shariq Akbar, David Schmitt, Peter Bayer, Tobias Schrag

    The integration of Functional Mock-up Units (FMUs) enableseffective multi-domain co-simulation and model exchange,offering new possibilities for energy systems modellingconsidering thermo-hydraulic aspects. This paper presents acase study on incorporating an FMU of a seasonal thermalenergy storage (sTES), developed in Modelica/Dymola, into aMATLAB/Simscape model of a thermal source network (TSN).While traditional thermo-hydraulic models are typicallyconfined to a single simulation environment, this studydemonstrates the feasibility and advantages of FMU-basedinteroperability between Modelica/Dymola andMATLAB/Simscape.A key focus is the methodological approach for integratingFMUs into Simscape, addressing interface requirements,solver settings, and model coupling challenges. Toillustrate the impact of FMU integration, the authorspresent simulation results for exemplary operationscenarios: TSN operation with and without an sTES.Additionally, our simulation results offer valuableinsights into the influence of sTES on TSN operation andsystem layout.

  • Open Access

    Implementation of an expanding thermal source network as a step towards CO2-neutral industry

    by Simon Müller, Christoph Bott, David Schmitt, Markus Faigl, Klaus Göttl, Rainer Strobel, Peter Bayer, Tobias Schrag


  • Open Access

    Analysis of Industrial 5GDHC System in Ingolstadt

    by Simon Nikolaus Müller, Rainer Strobel, Markus Faigl, Tobias Schrag

    This study comprehensively examines the technical manifestation and planning process for a shared thermal energy network at a 75-hectare industrial area in Ingolstadt. Unlike traditional systems, this (5GDHC) network showcases a smart integration of energy flows across 70 buildings with a yearly heating demand of around 17 GWh and a yearly cooling demand of around 35 GWh. The network spans over 9,100 meters of piping with diameters up to 800 mm. With thermal power from various sources including 1.8 MW waste heat from a data centre and potential for 10 MW from the Danube River, the system epitomizes a dynamic balance of heating and cooling demands. The paper itself examines the planning process of the system and encompasses topics such as defining energy requirements and load profiles, assessing potential energy sources and sinks for enhanced system efficiency, and analysing pipe and network design. Through this investigation, the study provides valuable insights towards a methodology to facilitate the successful implementation of future industrial 5GDHC systems, furthering the cause of sustainable energy.


  • Open Access

    Intermittent Operations of District Heating Networks in Summer Months

    by Anna Vannahme, Simon Müller, David Schmitt, Thorsten Summ, Christoph Trinkl, Tobias Schrag

    In the OREWA project, optimization measures for existing heat networks were identified and assessed based on both economic and ecological considerations [1]. One of the focal investigations was the simulation of intermittent operational strategies tailored for the summer months. Next to the classic intermittent approach an innovative variation was explored, which involved the storage of hot water during intermediate phases in large central tanks to further minimize heat losses. Both the classic and innovative intermittent strategies showcased substantial reductions in network losses and energy consumption for circulation pumps. This research shows the melioration of heat network efficiency through a substantial reduction of summer heat losses for a network with a low heat demand density of 0.7 MWh/(m²·a).