David Schmitt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Schmitt has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Thorsten Summ
Technische Hochschule Ingolstadt
8 shared publications Tobias Schrag
7 shared publications- Simon Müller
Technische Hochschule Ingolstadt
6 shared publications - Tobias Reum
Technische Hochschule Ingolstadt
5 shared publications - Tobias Schrag
Technische Hochschule Ingolstadt
5 shared publications Christoph Trinkl
4 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Economic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks
Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEconomic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks
Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.
- Open Access
- 15 October 2026
- Published by Elsevier in SSRN Electronic Journal
Economic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks
Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.
- 15 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEconomic feasibility of waste heat integration from high-power charging stations for electric trucks in district heating networks
Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.
- Open Access
- 22 May 2026
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 239
Understanding buried dynamics: The relevance of pipe–ground interaction in thermal networks
- 22 May 2026
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 239
Open AccessUnderstanding buried dynamics: The relevance of pipe–ground interaction in thermal networks
- Open Access
- 17 April 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
The Potential of Agri-Solar Thermal Systems for Dual Land use Combining Agriculture and Large-Scale Solar Heat Generation
In view of the restricted availability of land for large-scale solar thermal systems in district heating, the creation of synergies in combining agricultural and energetic land use is of particular interest. Hence, the paper provides an overview and a qualitative evaluation of the conceptual options for Agri-Solar Thermal systems. Besides that, it outlines the requirements, boundary conditions and further development needs for these systems. The investigation reveals that vertical Agri-Solar Thermal with insulating glass flat-plate collectors is a promising concept due to the collectors' bifaciality and low adaptation efforts. Consequently, its solar yield potential was analysed in more detail, applying an analytical modelling approach. It was found that a vertical bifacial Agri-Solar Thermal system is capable to deliver a similar specific solar collector yield (470 kWh/(m²a)) compared to that of a conventional ground-mounted solar thermal system (494 kWh/(m²a)) for a Central European reference location (Würzburg, Germany), while reducing land use for collector mounting to less than one third (30.7 %). Hence, a vertical bifacial Agri-ST system could provide around three times more heat per square metre of occupied land than a conventional setup (1,023 kWh/(m²a) vs. 330 kWh/(m²a)), highlighting the concept’s potential to enhance land use efficiency.
- 17 April 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Open AccessThe Potential of Agri-Solar Thermal Systems for Dual Land use Combining Agriculture and Large-Scale Solar Heat Generation
In view of the restricted availability of land for large-scale solar thermal systems in district heating, the creation of synergies in combining agricultural and energetic land use is of particular interest. Hence, the paper provides an overview and a qualitative evaluation of the conceptual options for Agri-Solar Thermal systems. Besides that, it outlines the requirements, boundary conditions and further development needs for these systems. The investigation reveals that vertical Agri-Solar Thermal with insulating glass flat-plate collectors is a promising concept due to the collectors' bifaciality and low adaptation efforts. Consequently, its solar yield potential was analysed in more detail, applying an analytical modelling approach. It was found that a vertical bifacial Agri-Solar Thermal system is capable to deliver a similar specific solar collector yield (470 kWh/(m²a)) compared to that of a conventional ground-mounted solar thermal system (494 kWh/(m²a)) for a Central European reference location (Würzburg, Germany), while reducing land use for collector mounting to less than one third (30.7 %). Hence, a vertical bifacial Agri-ST system could provide around three times more heat per square metre of occupied land than a conventional setup (1,023 kWh/(m²a) vs. 330 kWh/(m²a)), highlighting the concept’s potential to enhance land use efficiency.
- Open Access
- 10 April 2026
- Published by Elsevier in SSRN Electronic Journal
Optimal Integration of Seasonal Thermal Energy Storage in a Thermal Source Network
Thermal Source Networks (TSNs) are a key element of future district energy systems, because they enable the integration of locally available diverse renewable and waste-heat sources. Seasonal thermal energy storage (sTES) can enhance TSN flexibility by enabling inter-seasonal energy shifting and mitigating mismatches between supply and demand. This study investigates the optimal integration of a retrofit sTES into a TSN, using the incampus industrial park in Ingolstadt, Germany, as a case study. A dynamic simulation framework is developed by coupling a MATLAB/Simscape TSN model with a physics-based sTES model developed in Modelica/Dymola and exported as Functional Mock-up Unit. A parametric assessment is performed by varying key sTES design parameters (e.g., insulation) and demand characteristics (e.g., demand simultaneity). Performance is evaluated using three indicators: sTES efficiency, heating and cooling demand coverage, and levelized cost of thermal service (LCOTS). Results show that improved insulation and compact geometry increase storage efficiency by 21% and reduce LCOTS by 13%, whereas increasing sTES volume can increase LCOTS by 40%. A heat pump-assisted charging option extends the sTES usable temperature range and increases demand coverage by 16% without substantially increasing thermal losses. In contrast, higher demand simultaneity between heating and cooling reduces sTES utilization and leads to a pronounced increase in LCOTS by 125%. Overall, the analysis identifies a near-Pareto-optimal configuration that balances efficiency, coverage, and cost, and provides practical guidelines for integrating seasonal storage in next-generation low-temperature thermal networks.
- 10 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimal Integration of Seasonal Thermal Energy Storage in a Thermal Source Network
Thermal Source Networks (TSNs) are a key element of future district energy systems, because they enable the integration of locally available diverse renewable and waste-heat sources. Seasonal thermal energy storage (sTES) can enhance TSN flexibility by enabling inter-seasonal energy shifting and mitigating mismatches between supply and demand. This study investigates the optimal integration of a retrofit sTES into a TSN, using the incampus industrial park in Ingolstadt, Germany, as a case study. A dynamic simulation framework is developed by coupling a MATLAB/Simscape TSN model with a physics-based sTES model developed in Modelica/Dymola and exported as Functional Mock-up Unit. A parametric assessment is performed by varying key sTES design parameters (e.g., insulation) and demand characteristics (e.g., demand simultaneity). Performance is evaluated using three indicators: sTES efficiency, heating and cooling demand coverage, and levelized cost of thermal service (LCOTS). Results show that improved insulation and compact geometry increase storage efficiency by 21% and reduce LCOTS by 13%, whereas increasing sTES volume can increase LCOTS by 40%. A heat pump-assisted charging option extends the sTES usable temperature range and increases demand coverage by 16% without substantially increasing thermal losses. In contrast, higher demand simultaneity between heating and cooling reduces sTES utilization and leads to a pronounced increase in LCOTS by 125%. Overall, the analysis identifies a near-Pareto-optimal configuration that balances efficiency, coverage, and cost, and provides practical guidelines for integrating seasonal storage in next-generation low-temperature thermal networks.
- Open Access
Implementation of an expanding thermal source network as a step towards CO2-neutral industry
- Open Access
- 18 December 2024
- Published by Elsevier in International Journal of Refrigeration
- Vol. 171, 124-138
Experimental analysis of parallel operation of two heat sources in a dual-source heat pump incorporating two compressors
- 18 December 2024
- Published by Elsevier in International Journal of Refrigeration
- Vol. 171, 124-138
Open AccessExperimental analysis of parallel operation of two heat sources in a dual-source heat pump incorporating two compressors
- Open Access
- 11 July 2024
- Published by Atlantis Press SARL
- p. 205-211
Potential of a Long-Term Predictive Controller for Managing Energy Storages to Reduce the Electric Grid-Load of an Air-Source Heat Pump
- 11 July 2024
- Published by Atlantis Press SARL
- p. 205-211
Open AccessPotential of a Long-Term Predictive Controller for Managing Energy Storages to Reduce the Electric Grid-Load of an Air-Source Heat Pump