NNNoa B. Nuzov

Noa B. Nuzov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Noa B. Nuzov has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mapping the Fascicular Morphology and Organization of the Human Sciatic Nerve via High-Resolution MicroCT Imaging

    by Jichu Zhang, Valerie H. Lam, Noa B. Nuzov, Brandon A. S. Brunsman, Tatiana Pascol, Ashley Onabiyi, Rebecca Prince, Havisha Kalpatthi, Kenneth Gustafson, Ronald Triolo, et al.

    Objective: Implanted neuroprostheses can restore standing and walking after spinal cord injury and somatosensation after limb loss. Yet current approaches often fail to reliably activate hamstring muscles crucial for upright stability and mobility or to target afferent fibers for sensory restoration. We developed a novel methodology using high-resolution micro-computed tomography (microCT) to visualize and track fascicle groups innervating distinct hamstring muscles along the human sciatic nerve. This approach provides a framework for mapping fascicular topography in complex neural pathways to optimize standing neuroprostheses. Methods: Bilateral sciatic nerves were dissected and excised from an embalmed human cadaver, annotated with branch names, and stained with phosphotungstic acid before undergoing microCT scanning at 11.4 μm isotropic resolution. Images were segmented with a 3D U-Net convolutional neural network. Segmentation results were used to quantify morphological metrics and track fascicular organization along ∼25 cm of the nerve. MicroCT reconstructions were validated against histological cross sections. Results: Gross dissection revealed matched proximal-to-distal branching between left and right sciatic nerves: branch to long head of the biceps femoris (lhBF), branch to hamstring part of the adductor magnus and semimembranosus (HAM/SM), and branch to semitendinosus (ST). All branches originated medially and followed an inferomedial trajectory. Branch-free lengths of the sciatic exhibited asymmetry, especially between the lumbosacral roots to the first branch (5.5 cm left vs. 1.5 cm right) and lhBF to the HAM/SM branch (9.0 cm left vs. 16.5 cm right). MicroCT analysis revealed bilateral symmetry in fascicle diameters (∼0.4 mm) and total fascicle counts (∼84) but asymmetry in hamstring-innervating fascicle counts (left ∼7, right: ∼9). The 3D fascicular maps revealed that hamstring fascicles were located in the anteromedial portion of the sciatic nerve cross section and remained separate for distances up to 15.9 cm proximal to their branching points. Significance: Our microCT-based approach enables efficient, high-resolution 3D mapping of fascicular organization within large, complex peripheral nerves like the sciatic nerve, overcoming previous technical limitations. This methodology informs development of neuroprostheses with improved hamstring muscle activation for enhanced standing function.

  • Variations in Determining Actual Orientations of Segmented Deep Brain Stimulation Leads Using the DiODe Algorithm: A Retrospective Study Across Different Lead Designs and Medical Institutions

    by Kaylee R. Henry, Milina Michelle Miulli, Noa B. Nuzov, Mark J. Nolt, Joshua M. Rosenow, Behzad Elahi, Julie Pilitsis, Laleh Golestanirad

    Introduction: Directional deep brain stimulation (DBS) leads have become widely used in the past decade. Understanding the asymmetric stimulation provided by directional leads requires precise knowledge of the exact orientation of the lead in respect to its anatomical target. Recently, the DiODe algorithm was developed to automatically determine the orientation angle of leads from the artifact on postoperative computed tomography (CT) images. However, manual DiODe results are user-dependent. This study analyzed the extent of lead rotation as well as the user agreement of DiODe calculations across the two most common DBS systems, namely, Boston Scientific’s Vercise and Abbott’s Infinity, and two independent medical institutions. Methods: Data from 104 patients who underwent an anterior-facing unilateral/bilateral directional DBS implantation at either Northwestern Memorial Hospital (NMH) or Albany Medical Center (AMC) were retrospectively analyzed. Actual orientations of the implanted leads were independently calculated by three individual users using the DiODe algorithm in Lead-DBS and patients’ postoperative CT images. The deviation from the intended orientation and user agreement were assessed. Results: All leads significantly deviated from the intended 0° orientation (p < 0.001), regardless of DBS lead design (p < 0.05) or institution (p < 0.05). However, the Boston Scientific leads showed an implantation bias toward the left at both institutions (p = 0.014 at NMH, p = 0.029 at AMC). A difference of 10° between at least two users occurred in 28% (NMH) and 39% (AMC) of all Boston Scientific and 76% (NMH) and 53% (AMC) of all Abbott leads. Conclusion: Our results show that there is a significant lead rotation from the intended surgical orientation across both DBS systems and both medical institutions; however, a bias toward a single direction was only seen in the Boston Scientific leads. Additionally, these results raise questions into the user error that occurs when manually refining the orientation angles calculated with DiODe.


  • Open Access

    Artifacts Can Be Deceiving: The Actual Location of Deep Brain Stimulation Electrodes Differs from the Artifact Seen on Magnetic Resonance Images

    by Noa B. Nuzov, Bhumi Bhusal, Kaylee R. Henry, Fuchang Jiang, Jasmine Vu, Joshua M. Rosenow, Julie G. Pilitsis, Behzad Elahi, Laleh Golestanirad

    Introduction: Deep brain stimulation (DBS) is a common treatment for a variety of neurological and psychiatric disorders. Recent studies have highlighted the role of neuroimaging in localizing the position of electrode contacts relative to target brain areas in order to optimize DBS programming. Among different imaging methods, postoperative magnetic resonance imaging (MRI) has been widely used for DBS electrode localization; however, the geometrical distortion induced by the lead limits its accuracy. In this work, we investigated to what degree the difference between the actual location of the lead’s tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters such as acquisition plane and phase encoding direction, as well as the lead’s extracranial configuration. Accordingly, an imaging technique to increase the accuracy of lead localization was devised and discussed. Methods: We designed and constructed an anthropomorphic phantom with an implanted DBS system following 18 clinically relevant configurations. The phantom was scanned at a Siemens 1.5 Tesla Aera scanner using a T1MPRAGE sequence optimized for clinical use and a T1TSE sequence optimized for research purposes. We varied slice acquisition plane and phase encoding direction and calculated the distance between the caudal tip of the DBS lead MRI artifact and the actual tip of the lead, as estimated from MRI reference markers. Results: Imaging parameters and lead configuration substantially altered the difference in the depth of the lead within its MRI artifact on the scale of several millimeters − with a difference as large as 4.99 mm. The actual tip of the DBS lead was found to be consistently more rostral than the tip estimated from the MR image artifact. The smallest difference between the tip of the DBS lead and the tip of the MRI artifact using the clinically relevant sequence (i.e., T1MPRAGE) was found with the sagittal acquisition plane and anterior-posterior phase encoding direction. Discussion/Conclusion: The actual tip of an implanted DBS lead is located up to several millimeters rostral to the tip of the lead’s artifact on postoperative MR images. This distance depends on the MRI sequence parameters and the DBS system’s extracranial trajectory. MRI parameters may be altered to improve this localization.