RBRhonda Brown

Rhonda Brown

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rhonda Brown has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ACPSEM guideline regarding the adoption of the IAEA TRS-398 Code of Practice Revision 1

    by Joerg Lehmann, Jeffrey Barber, Andrew Alves, Simon Berke, Rhonda Brown, Peter Harty, Brendan Healy, Robin Hill, Stewart Midgley, Vaughan Moutrie, et al.

    The IAEA Technical Report Series 398 Code of Practice for the determination of absorbed dose in external beam radiotherapy was endorsed at the Engineers and Physical Scientists in Medicine (EPSM) conference in 2001 and has been widely adopted in Australia and New Zealand. This guideline provides recommendations from the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) following the recent publication of TRS-398 Revision 1. It is jointly authored by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), the Reference Dosimetry Advisory Group (RDAG) and the ACPSEM Radiation Oncology Specialty Group (ROSG). In addition to recommendations, the guideline discusses the implications of TRS-398 Revision 1 for the dosimetry of megavoltage photons, electrons and protons. TRS-398 Revision 1 is recommended for adoption in accordance with the recommendations provided in this guideline, including for FFF beams. For specialised FFF machines such as CyberKnife ® and TomoTherapy ® , and for Gamma Knife ® , the ACPSEM recommends the use of IAEA TRS-483 Code of Practice. MR linacs are covered by the ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators and in AAPM TG-351. For kilovoltage photons, the recommendation to use the AAPM TG-61 protocol for radiotherapy sources is retained and now specifically also includes cabinet irradiators used in radiobiology.

  • Open Access

    Measuring dose in lung identifies peripheral tumour dose inaccuracy in SBRT audit

    by Maddison Shaw, Jessica Lye, Andrew Alves, Joerg Lehmann, Masoumeh Sanagou, Moshi Geso, Rhonda Brown


  • Open Access

    ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators

    by Jarrad Begg, Urszula Jelen, Zoe Moutrie, Chris Oliver, Lois Holloway, Rhonda Brown, the ACPSEM Magnetic Resonance Imaging Linac Working Group (MRILWG)

    Consistency and clear guidelines on dosimetry are essential for accurate and precise dosimetry, to ensure the best patient outcomes and to allow direct dose comparison across different centres. Magnetic Resonance Imaging Linac (MRI-linac) systems have recently been introduced to Australasian clinics. This report provides recommendations on reference dosimetry measurements for MRI-linacs on behalf of the Australiasian College of Physical Scientists and Engineers in Medicine (ACPSEM) MRI-linac working group. There are two configurations considered for MRI-linacs, perpendicular and parallel, referring to the relative direction of the magnetic field and radiation beam, with different impacts on dose deposition in a medium. These recommendations focus on ion chambers which are most commonly used in the clinic for reference dosimetry. Water phantoms must be MR safe or conditional and practical limitations on phantom set-up must be considered. Solid phantoms are not advised for reference dosimetry. For reference dosimetry, IAEA TRS-398 recommendations cannot be followed completely due to physical differences between conventional linac and MRI-linac systems. Manufacturers’ advice on reference conditions should be followed. Beam quality specification of TPR20,10 is recommended. The configuration of the central axis of the ion chamber relative to the magnetic field and radiation beam impacts the chamber response and must be considered carefully. Recommended corrections to delivered dose are $${k}_{{Q}_{msr}{Q}_{0}}^{{f}_{msr}{f}_{ref}}$$ k Q msr Q 0 f msr f ref , a correction for beam quality and $${k}_{\overrightarrow{B},{Q}_{msr}}^{{f}_{msr}}$$ k B → , Q msr f msr , for the impact of the magnetic field on dosimeter response in the magnetic field. Literature based values for $${k}_{\overrightarrow{B},{Q}_{msr}}^{{f}_{msr}}$$ k B → , Q msr f msr are given. It is important to note that this is a developing field and these recommendations should be used together with a review of current literature.