ACPSEM guideline regarding the adoption of the IAEA TRS-398 Code of Practice Revision 1
Authors:
- Joerg LehmannJLJoerg Lehmann
- Jeffrey BarberJBJeffrey Barber
- Andrew AlvesAAAndrew Alves
- Simon BerkeSBSimon Berke
- Rhonda BrownRBRhonda Brown
- Peter HartyPHPeter Harty
- Brendan HealyBHBrendan Healy
- Robin HillRHRobin Hill
- Stewart MidgleySMStewart Midgley
- Vaughan MoutrieVMVaughan Moutrie
- Chris OliverCOChris Oliver
- Scott PenfoldSPScott Penfold
Open Access
- 17 September 2026
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- p. 1-7
Abstract
The IAEA Technical Report Series 398 Code of Practice for the determination of absorbed dose in external beam radiotherapy was endorsed at the Engineers and Physical Scientists in Medicine (EPSM) conference in 2001 and has been widely adopted in Australia and New Zealand. This guideline provides recommendations from the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) following the recent publication of TRS-398 Revision 1. It is jointly authored by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), the Reference Dosimetry Advisory Group (RDAG) and the ACPSEM Radiation Oncology Specialty Group (ROSG). In addition to recommendations, the guideline discusses the implications of TRS-398 Revision 1 for the dosimetry of megavoltage photons, electrons and protons. TRS-398 Revision 1 is recommended for adoption in accordance with the recommendations provided in this guideline, including for FFF beams. For specialised FFF machines such as CyberKnife ® and TomoTherapy ® , and for Gamma Knife ® , the ACPSEM recommends the use of IAEA TRS-483 Code of Practice. MR linacs are covered by the ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators and in AAPM TG-351. For kilovoltage photons, the recommendation to use the AAPM TG-61 protocol for radiotherapy sources is retained and now specifically also includes cabinet irradiators used in radiobiology.Keywords
Funding Information
- The University of Newcastle
This publication has 7 references indexed in Scilit:
- AAPM task group report 351: Protocol for clinical reference dosimetry in external beam MR‐guided radiotherapyMedical Physics, 2025
- Absorbed Dose Determination in External Beam Radiotherapy2024
- ACPSEM position paper: dosimetry for magnetic resonance imaging linear acceleratorsPhysical and Engineering Sciences in Medicine, 2023
- AAPM WGTG51 Report 374: Guidance for TG‐51 reference dosimetryMedical Physics, 2022
- Determination of consensus k
Q
values for megavoltage photon beams for the update of IAEA TRS-398Physics in Medicine & Biology, 2020
- Australasian recommendations for quality assurance in kilovoltage radiation therapy from the Kilovoltage Dosimetry Working Group of the Australasian College of Physical Scientists and Engineers in MedicineAustralasian Physics & Engineering Sciences in Medicine, 2018
- AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiologyMedical Physics, 2001