Kun Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kun Tang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chaoqun Li
State Key Laboratory of Aerodynamics, China Aerodynamics Research and Development Center, Mianyang 621000, China
1 shared publication - Jiaxin Pan
State Key Laboratory of Aerodynamics, China Aerodynamics Research and Development Center, Mianyang 621000, China
1 shared publication - Qi Lin
School of Aerospace Engineering, Xiamen University 1 , Xiamen 361102
1 shared publication - Rubing Liu
School of Aerospace Engineering, Xiamen University 1 , Xiamen 361102
1 shared publication - Shenghui Xue
School of Aerospace Engineering, Xiamen University, Xiamen 361102, China
1 shared publication - Wanbo Wang
State Key Laboratory of Aerodynamics, China Aerodynamics Research and Development Center, Mianyang, China
1 shared publication
Latest Publications
- Open Access
Experimental Investigation on Flow Control over a Circular Cylinder Using Antiphase Pulsed Jets
To investigate the flow control characteristics of antiphase pulsed jet technology and explore a more efficient method to control unsteady flow with minimal impact on flow turbulence, wind tunnel experiments were conducted. The aim was to address the issue of flow separation control on the surface of a cylindrical model. The model had a diameter of 100 mm, and an experimental setup utilizing an antiphase pulsed jet excitation was developed. The optimisation of unsteady jet control involved adjusting parameters such as jet momentum coefficient, slot position, and excitation frequency. The flow separation control effect on the cylinder surface was compared between in-phase and antiphase pulsed jet using a particle image velocimetry (PIV) technique. The mechanisms of flow control for these two methods were analysed. The results showed that in still air, increasing the jet momentum led to a gradual decrease in the high-velocity region, which also moved away from the wall. Under incoming flow conditions, positioning the slot closer to the separation point resulted in better flow separation control, particularly when the excitation frequency matched the main flow frequency. Both in-phase and antiphase pulsed jet excitations effectively suppressed flow separation. In the near-wall region within the symmetric plane between the two slots, the antiphase excitation reduced the root mean square of velocity fluctuations by approximately 1.9% and increased the average velocity by approximately 15.5% compared to in-phase pulsed jet excitation. In-phase pulsed jets exhibited low-frequency, high-velocity characteristics near the separation point, while antiphase pulsed jets, due to the alternating discharge of the two jets, had a lesser impact on the flow field turbulence.
Open AccessExperimental Investigation on Flow Control over a Circular Cylinder Using Antiphase Pulsed Jets
To investigate the flow control characteristics of antiphase pulsed jet technology and explore a more efficient method to control unsteady flow with minimal impact on flow turbulence, wind tunnel experiments were conducted. The aim was to address the issue of flow separation control on the surface of a cylindrical model. The model had a diameter of 100 mm, and an experimental setup utilizing an antiphase pulsed jet excitation was developed. The optimisation of unsteady jet control involved adjusting parameters such as jet momentum coefficient, slot position, and excitation frequency. The flow separation control effect on the cylinder surface was compared between in-phase and antiphase pulsed jet using a particle image velocimetry (PIV) technique. The mechanisms of flow control for these two methods were analysed. The results showed that in still air, increasing the jet momentum led to a gradual decrease in the high-velocity region, which also moved away from the wall. Under incoming flow conditions, positioning the slot closer to the separation point resulted in better flow separation control, particularly when the excitation frequency matched the main flow frequency. Both in-phase and antiphase pulsed jet excitations effectively suppressed flow separation. In the near-wall region within the symmetric plane between the two slots, the antiphase excitation reduced the root mean square of velocity fluctuations by approximately 1.9% and increased the average velocity by approximately 15.5% compared to in-phase pulsed jet excitation. In-phase pulsed jets exhibited low-frequency, high-velocity characteristics near the separation point, while antiphase pulsed jets, due to the alternating discharge of the two jets, had a lesser impact on the flow field turbulence.
- Open Access
Internal Characteristics of Air-Supplied Plasma Synthetic Jet Actuator
Conventional plasma synthetic jet actuators rely only on jet orifice for suction when functioning for long durations. A limited supplementary gas leads to jet velocity reduction and weakening of the flow control ability. Therefore, this study proposes an air-supplied actuator with a check valve externally connected to the cavity to improve its gas-supplying ability and jet performance. A quartz glass discharge chamber is developed to clarify the internal working mechanism of the air-supplied actuator. High-speed schlieren is employed to photograph the internal flow field of the discharge chamber. The results reveal that the inhalation airflow velocity of the jet orifice is doubled when the actuator is continuously working in the effective frequency band under the combined action of additional air supply from the check valve in the inhalation recovery stage. The gas pressure in the cavity is closer to the initial discharge state, discharge breakdown voltage is higher, discharge energy is stronger, and the process of gas expansion to generate a jet is less affected by the core defect of the heat source, thereby significantly increasing the jet velocity and saturation operating frequency of the actuator. The obtained results have important implications for the performance optimization of the air-supplied actuator.
Open AccessInternal Characteristics of Air-Supplied Plasma Synthetic Jet Actuator
Conventional plasma synthetic jet actuators rely only on jet orifice for suction when functioning for long durations. A limited supplementary gas leads to jet velocity reduction and weakening of the flow control ability. Therefore, this study proposes an air-supplied actuator with a check valve externally connected to the cavity to improve its gas-supplying ability and jet performance. A quartz glass discharge chamber is developed to clarify the internal working mechanism of the air-supplied actuator. High-speed schlieren is employed to photograph the internal flow field of the discharge chamber. The results reveal that the inhalation airflow velocity of the jet orifice is doubled when the actuator is continuously working in the effective frequency band under the combined action of additional air supply from the check valve in the inhalation recovery stage. The gas pressure in the cavity is closer to the initial discharge state, discharge breakdown voltage is higher, discharge energy is stronger, and the process of gas expansion to generate a jet is less affected by the core defect of the heat source, thereby significantly increasing the jet velocity and saturation operating frequency of the actuator. The obtained results have important implications for the performance optimization of the air-supplied actuator.