Tomoyuki Koga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tomoyuki Koga has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ryuya Ando
Hitach LTD., Hitachi, Japan
3 shared publications Tomoo Chiba
Hitach LTD., Hitachi, Japan
3 shared publications- Hiroyuki Watanabe
Radiation and Magnetic Application Design Dept. Therapy System Business, Hitachi High-Tech Corporation Healthcare Business Group, Hitachi, Ibaraki, Japan
2 shared publications - Ken-Ichi Sasaki
High Energy Accelerator Research Organization, J-PARC center, Tokai-mura, Japan
2 shared publications - Mitsushi Abe
High Energy Accelerator Research Organization (KEK), Tsukuba, Japan
2 shared publications - Naohito Saito
University of Tokyo
2 shared publications
Latest Publications
- 1 February 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (2) , 025006
Development and excitation test of an MgB 2 coil with a central magnetic field of 2 T
An MgB 2 coil with the central magnetic field of 2 T was designed, manufactured, and successfully excited. It was cooled down to 10 K by conduction cooling using a cryocooler and excited to the rated current of 112 A at a ramp-up rate of 0.1–0.3 A s −1 . For quench protection, 0.5 mm copper plates were inserted in the winding to enhance thermal conductivity and a 1 Ω protection resistor that consumes a stored energy of 2.1 kJ was installed outside a cryostat. We conducted a quench test by intentionally raising the temperature of the coil to confirm the performance of the quench protection. Although a quench occurred at a winding surface temperature of 19.4 K during the 2 T excitation state, the coil was cooled down and excited again without any subsequent anomalies. In contrast, an unexpected power supply shutdown occurred during the first excitation. Considering other events such as a sharp drop in the coil voltage during an excitation, we evaluated this as a training quench due to a slight movement of the coil by a hoop force.
- 1 February 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (2) , 025006
Development and excitation test of an MgB 2 coil with a central magnetic field of 2 T
An MgB 2 coil with the central magnetic field of 2 T was designed, manufactured, and successfully excited. It was cooled down to 10 K by conduction cooling using a cryocooler and excited to the rated current of 112 A at a ramp-up rate of 0.1–0.3 A s −1 . For quench protection, 0.5 mm copper plates were inserted in the winding to enhance thermal conductivity and a 1 Ω protection resistor that consumes a stored energy of 2.1 kJ was installed outside a cryostat. We conducted a quench test by intentionally raising the temperature of the coil to confirm the performance of the quench protection. Although a quench occurred at a winding surface temperature of 19.4 K during the 2 T excitation state, the coil was cooled down and excited again without any subsequent anomalies. In contrast, an unexpected power supply shutdown occurred during the first excitation. Considering other events such as a sharp drop in the coil voltage during an excitation, we evaluated this as a training quench due to a slight movement of the coil by a hoop force.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design of the Superconducting Magnet System for the New $g-2$/EDM Experiment in the J-PARC
A superconducting solenoid system has been designed for the $g$ -2/EDM experiment at the J-PARC, which is used to store muon beam of 0.3 GeV/c. High homogeneous magnetic field is required to be below $\pm$ 0.1 ppm at 3 T within a muon storage region of 33.3 $\pm$ 1.5 cm in radius and $\mathbf {\pm }$ 5 cm in height around the magnet center. The muon beam is spirally injected to the storage region from the top end of the magnet, therefore the magnetic field distribution is carefully designed in the region where the muon beam pass through. In order to achieve both requirements, NbTi superconducting coils are surrounded by an iron yoke with pole tips, which can optimize the field distribution by adjusting the shape and size. The superconducting coils are cooled by pool boiling in liquid helium, and the evaporated helium gas is re-condensed by GM cryocoolers to keep the liquid helium level for a long time. The main coils are operated in a persistent current mode to remove the magnetic field fluctuation with time caused by a power supply. This paper presents the current design of the magnet system for the experiment at the J-PARC.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design of the Superconducting Magnet System for the New $g-2$/EDM Experiment in the J-PARC
A superconducting solenoid system has been designed for the $g$ -2/EDM experiment at the J-PARC, which is used to store muon beam of 0.3 GeV/c. High homogeneous magnetic field is required to be below $\pm$ 0.1 ppm at 3 T within a muon storage region of 33.3 $\pm$ 1.5 cm in radius and $\mathbf {\pm }$ 5 cm in height around the magnet center. The muon beam is spirally injected to the storage region from the top end of the magnet, therefore the magnetic field distribution is carefully designed in the region where the muon beam pass through. In order to achieve both requirements, NbTi superconducting coils are surrounded by an iron yoke with pole tips, which can optimize the field distribution by adjusting the shape and size. The superconducting coils are cooled by pool boiling in liquid helium, and the evaporated helium gas is re-condensed by GM cryocoolers to keep the liquid helium level for a long time. The main coils are operated in a persistent current mode to remove the magnetic field fluctuation with time caused by a power supply. This paper presents the current design of the magnet system for the experiment at the J-PARC.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Study of Vibration Effect on Magnetic Field Homogeneity in the Magnet System for the $g-2$/EDM Experiment at the J-PARC
In a superconducting solenoid used as the muon storage magnet in the J-PARC $g-2$ /EDM experiment, high homogeneous magnetic field of less than $\mathbf {\pm }$ 0.1 ppm at 3 T is required. A study on source of magnetic field disturbance is much important to achieve such high homogeneous magnetic field, and a vibration is one of the serious concerns in terms of dynamic error source of magnetic field. Two vibration sources were considered, a seismic vibration and GM cryocoolers. A frequency response analysis was carried out in the magnet system to evaluate the magnitude of the vibration of magnet using ANSYS. The analysis results shows that the displacement of main coil due to a seismic vibration at J-PARC would be about 0.69 and 0.43 $\boldsymbol{\mu }$ m in the horizontal and vertical direction at maximum, respectively. The coil vibration caused by GM cryocoolers was calculated to be negligible, less than 1 $\mathbf {\times }$ $\mathbf {10^{-3}}$ $\boldsymbol{\mu }$ m, thanks to the vibration isolation design of a cold box and a liquid helium transfer tube. The evaluated magnetic field error due to the cryocooler vibration was less than $\pm$ 1 $\mathbf {\times }$ $\mathbf {10^{-4}}$ ppm, which was much smaller than the requirement of $\pm$ 0.1 ppm. On the other hand, the magnetic field error due to the coil displacement was evaluated to be $\pm$ 0.043 and $\pm$ 0.008 ppm in the horizontal and vertical directions, these were not negligibly small compared with the requirement, especially in the horizontal direction. In order to reduce the vibration conducted through the ground, the vibration dumping system is planned to be implemented in the practical magnet system.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Study of Vibration Effect on Magnetic Field Homogeneity in the Magnet System for the $g-2$/EDM Experiment at the J-PARC
In a superconducting solenoid used as the muon storage magnet in the J-PARC $g-2$ /EDM experiment, high homogeneous magnetic field of less than $\mathbf {\pm }$ 0.1 ppm at 3 T is required. A study on source of magnetic field disturbance is much important to achieve such high homogeneous magnetic field, and a vibration is one of the serious concerns in terms of dynamic error source of magnetic field. Two vibration sources were considered, a seismic vibration and GM cryocoolers. A frequency response analysis was carried out in the magnet system to evaluate the magnitude of the vibration of magnet using ANSYS. The analysis results shows that the displacement of main coil due to a seismic vibration at J-PARC would be about 0.69 and 0.43 $\boldsymbol{\mu }$ m in the horizontal and vertical direction at maximum, respectively. The coil vibration caused by GM cryocoolers was calculated to be negligible, less than 1 $\mathbf {\times }$ $\mathbf {10^{-3}}$ $\boldsymbol{\mu }$ m, thanks to the vibration isolation design of a cold box and a liquid helium transfer tube. The evaluated magnetic field error due to the cryocooler vibration was less than $\pm$ 1 $\mathbf {\times }$ $\mathbf {10^{-4}}$ ppm, which was much smaller than the requirement of $\pm$ 0.1 ppm. On the other hand, the magnetic field error due to the coil displacement was evaluated to be $\pm$ 0.043 and $\pm$ 0.008 ppm in the horizontal and vertical directions, these were not negligibly small compared with the requirement, especially in the horizontal direction. In order to reduce the vibration conducted through the ground, the vibration dumping system is planned to be implemented in the practical magnet system.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design and Manufacture of a Test Cryostat With MgB2 Superconducting Magnet Significantly Reducing Helium Consumption
A test cryostat equipped with a conduction-cooled MgB 2 high-temperature superconducting bias magnet has been designed, manufactured, and demonstrated. This cryostat is more environmental-friendly and user-friendly than the conventional cryostat with an immersion-cooled NbTi superconducting magnet. Liquid helium consumption is reduced by almost half of that of a previous conventional cryostat because the MgB 2 magnet does not need liquid helium for cooling itself. A ramp-up rate of the bias magnet has also been improved to 1 A/s, which is almost 10 times faster than that of the previous NbTi magnet, due to the high stability of the superconducting MgB 2 magnet. A maximum bias magnetic field is 1 T at the center of the magnet. A helium vessel of the cryostat is 212 mm in inner diameter so that various superconducting samples such as bulks, short samples of wires, and small coils, could be immersion-cooled by cryogen and tested in it. A performance demonstration was also successfully conducted.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design and Manufacture of a Test Cryostat With MgB2 Superconducting Magnet Significantly Reducing Helium Consumption
A test cryostat equipped with a conduction-cooled MgB 2 high-temperature superconducting bias magnet has been designed, manufactured, and demonstrated. This cryostat is more environmental-friendly and user-friendly than the conventional cryostat with an immersion-cooled NbTi superconducting magnet. Liquid helium consumption is reduced by almost half of that of a previous conventional cryostat because the MgB 2 magnet does not need liquid helium for cooling itself. A ramp-up rate of the bias magnet has also been improved to 1 A/s, which is almost 10 times faster than that of the previous NbTi magnet, due to the high stability of the superconducting MgB 2 magnet. A maximum bias magnetic field is 1 T at the center of the magnet. A helium vessel of the cryostat is 212 mm in inner diameter so that various superconducting samples such as bulks, short samples of wires, and small coils, could be immersion-cooled by cryogen and tested in it. A performance demonstration was also successfully conducted.
- 30 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Performance of MgB2 Superconductor Developed for High-Efficiency Klystron Applications
An 8-km long $MgB_{2}$ wire for a prototype Klystron magnet was made and evaluated. The wire was made by a typical in situ method; it has 10 filaments and 0.67 mm in outer diameter. The homogeneity of Ic of this wire was evaluated by several methods. Deviation of Ic values in short sample wires was very small. In addition, the current sharing temperature of the $MgB_{2}$ magnet (made of two reels of wire 2.9 km long each) agreed well with the estimated value of the Ic-B-T properties in short sample wires. Based on the obtained results, it can be said that the Ic properties of the entire wire length are quite uniform.- 30 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Performance of MgB2 Superconductor Developed for High-Efficiency Klystron Applications
An 8-km long $MgB_{2}$ wire for a prototype Klystron magnet was made and evaluated. The wire was made by a typical in situ method; it has 10 filaments and 0.67 mm in outer diameter. The homogeneity of Ic of this wire was evaluated by several methods. Deviation of Ic values in short sample wires was very small. In addition, the current sharing temperature of the $MgB_{2}$ magnet (made of two reels of wire 2.9 km long each) agreed well with the estimated value of the Ic-B-T properties in short sample wires. Based on the obtained results, it can be said that the Ic properties of the entire wire length are quite uniform.