Latest Publications
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design of the Superconducting Magnet System for the New $g-2$/EDM Experiment in the J-PARC
A superconducting solenoid system has been designed for the $g$ -2/EDM experiment at the J-PARC, which is used to store muon beam of 0.3 GeV/c. High homogeneous magnetic field is required to be below $\pm$ 0.1 ppm at 3 T within a muon storage region of 33.3 $\pm$ 1.5 cm in radius and $\mathbf {\pm }$ 5 cm in height around the magnet center. The muon beam is spirally injected to the storage region from the top end of the magnet, therefore the magnetic field distribution is carefully designed in the region where the muon beam pass through. In order to achieve both requirements, NbTi superconducting coils are surrounded by an iron yoke with pole tips, which can optimize the field distribution by adjusting the shape and size. The superconducting coils are cooled by pool boiling in liquid helium, and the evaporated helium gas is re-condensed by GM cryocoolers to keep the liquid helium level for a long time. The main coils are operated in a persistent current mode to remove the magnetic field fluctuation with time caused by a power supply. This paper presents the current design of the magnet system for the experiment at the J-PARC.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design of the Superconducting Magnet System for the New $g-2$/EDM Experiment in the J-PARC
A superconducting solenoid system has been designed for the $g$ -2/EDM experiment at the J-PARC, which is used to store muon beam of 0.3 GeV/c. High homogeneous magnetic field is required to be below $\pm$ 0.1 ppm at 3 T within a muon storage region of 33.3 $\pm$ 1.5 cm in radius and $\mathbf {\pm }$ 5 cm in height around the magnet center. The muon beam is spirally injected to the storage region from the top end of the magnet, therefore the magnetic field distribution is carefully designed in the region where the muon beam pass through. In order to achieve both requirements, NbTi superconducting coils are surrounded by an iron yoke with pole tips, which can optimize the field distribution by adjusting the shape and size. The superconducting coils are cooled by pool boiling in liquid helium, and the evaporated helium gas is re-condensed by GM cryocoolers to keep the liquid helium level for a long time. The main coils are operated in a persistent current mode to remove the magnetic field fluctuation with time caused by a power supply. This paper presents the current design of the magnet system for the experiment at the J-PARC.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Study of Vibration Effect on Magnetic Field Homogeneity in the Magnet System for the $g-2$/EDM Experiment at the J-PARC
In a superconducting solenoid used as the muon storage magnet in the J-PARC $g-2$ /EDM experiment, high homogeneous magnetic field of less than $\mathbf {\pm }$ 0.1 ppm at 3 T is required. A study on source of magnetic field disturbance is much important to achieve such high homogeneous magnetic field, and a vibration is one of the serious concerns in terms of dynamic error source of magnetic field. Two vibration sources were considered, a seismic vibration and GM cryocoolers. A frequency response analysis was carried out in the magnet system to evaluate the magnitude of the vibration of magnet using ANSYS. The analysis results shows that the displacement of main coil due to a seismic vibration at J-PARC would be about 0.69 and 0.43 $\boldsymbol{\mu }$ m in the horizontal and vertical direction at maximum, respectively. The coil vibration caused by GM cryocoolers was calculated to be negligible, less than 1 $\mathbf {\times }$ $\mathbf {10^{-3}}$ $\boldsymbol{\mu }$ m, thanks to the vibration isolation design of a cold box and a liquid helium transfer tube. The evaluated magnetic field error due to the cryocooler vibration was less than $\pm$ 1 $\mathbf {\times }$ $\mathbf {10^{-4}}$ ppm, which was much smaller than the requirement of $\pm$ 0.1 ppm. On the other hand, the magnetic field error due to the coil displacement was evaluated to be $\pm$ 0.043 and $\pm$ 0.008 ppm in the horizontal and vertical directions, these were not negligibly small compared with the requirement, especially in the horizontal direction. In order to reduce the vibration conducted through the ground, the vibration dumping system is planned to be implemented in the practical magnet system.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Study of Vibration Effect on Magnetic Field Homogeneity in the Magnet System for the $g-2$/EDM Experiment at the J-PARC
In a superconducting solenoid used as the muon storage magnet in the J-PARC $g-2$ /EDM experiment, high homogeneous magnetic field of less than $\mathbf {\pm }$ 0.1 ppm at 3 T is required. A study on source of magnetic field disturbance is much important to achieve such high homogeneous magnetic field, and a vibration is one of the serious concerns in terms of dynamic error source of magnetic field. Two vibration sources were considered, a seismic vibration and GM cryocoolers. A frequency response analysis was carried out in the magnet system to evaluate the magnitude of the vibration of magnet using ANSYS. The analysis results shows that the displacement of main coil due to a seismic vibration at J-PARC would be about 0.69 and 0.43 $\boldsymbol{\mu }$ m in the horizontal and vertical direction at maximum, respectively. The coil vibration caused by GM cryocoolers was calculated to be negligible, less than 1 $\mathbf {\times }$ $\mathbf {10^{-3}}$ $\boldsymbol{\mu }$ m, thanks to the vibration isolation design of a cold box and a liquid helium transfer tube. The evaluated magnetic field error due to the cryocooler vibration was less than $\pm$ 1 $\mathbf {\times }$ $\mathbf {10^{-4}}$ ppm, which was much smaller than the requirement of $\pm$ 0.1 ppm. On the other hand, the magnetic field error due to the coil displacement was evaluated to be $\pm$ 0.043 and $\pm$ 0.008 ppm in the horizontal and vertical directions, these were not negligibly small compared with the requirement, especially in the horizontal direction. In order to reduce the vibration conducted through the ground, the vibration dumping system is planned to be implemented in the practical magnet system.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design and Manufacture of a Test Cryostat With MgB2 Superconducting Magnet Significantly Reducing Helium Consumption
A test cryostat equipped with a conduction-cooled MgB 2 high-temperature superconducting bias magnet has been designed, manufactured, and demonstrated. This cryostat is more environmental-friendly and user-friendly than the conventional cryostat with an immersion-cooled NbTi superconducting magnet. Liquid helium consumption is reduced by almost half of that of a previous conventional cryostat because the MgB 2 magnet does not need liquid helium for cooling itself. A ramp-up rate of the bias magnet has also been improved to 1 A/s, which is almost 10 times faster than that of the previous NbTi magnet, due to the high stability of the superconducting MgB 2 magnet. A maximum bias magnetic field is 1 T at the center of the magnet. A helium vessel of the cryostat is 212 mm in inner diameter so that various superconducting samples such as bulks, short samples of wires, and small coils, could be immersion-cooled by cryogen and tested in it. A performance demonstration was also successfully conducted.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design and Manufacture of a Test Cryostat With MgB2 Superconducting Magnet Significantly Reducing Helium Consumption
A test cryostat equipped with a conduction-cooled MgB 2 high-temperature superconducting bias magnet has been designed, manufactured, and demonstrated. This cryostat is more environmental-friendly and user-friendly than the conventional cryostat with an immersion-cooled NbTi superconducting magnet. Liquid helium consumption is reduced by almost half of that of a previous conventional cryostat because the MgB 2 magnet does not need liquid helium for cooling itself. A ramp-up rate of the bias magnet has also been improved to 1 A/s, which is almost 10 times faster than that of the previous NbTi magnet, due to the high stability of the superconducting MgB 2 magnet. A maximum bias magnetic field is 1 T at the center of the magnet. A helium vessel of the cryostat is 212 mm in inner diameter so that various superconducting samples such as bulks, short samples of wires, and small coils, could be immersion-cooled by cryogen and tested in it. A performance demonstration was also successfully conducted.