Tomomi Nakano
Research Subjects
Tomomi Nakano has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Shota Ushiba
Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan
3 shared publications - Kazuhiko Matsumoto
Osaka University
2 shared publications - Masahiko Kimura
Murata Manufacturing Co., Ltd
2 shared publications - Shinsuke Tani
Murata Manufacturing Co., Ltd
2 shared publications - Ayumi Shinagawa
Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan
1 shared publication - Eiichi Tamiya
Osaka University
1 shared publication
Latest Publications
- Open Access
- 30 October 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Electrochemiluminescence Detection in Optically Dense Solutions Through Transparent Graphene Electrodes
Electrochemiluminescence (ECL) enables highly sensitive bioanalytical detection; however, its practical application is constrained by strong optical absorption in colored or optically dense samples, which significantly attenuates the emitted signal. In this study, we address this limitation by employing transparent graphene electrodes for enzyme-mediated ECL detection in optically dense liquids. Glutamate oxidase was immobilized in proximity to the electrode surface to catalyze the conversion of glutamate into hydrogen peroxide, which subsequently initiated luminol-based ECL. The integrated ECL intensity increased with glutamate concentration and followed a Michaelis–Menten–type relationship, confirming that the signal originated from the enzymatic reaction. When evaluated in soy sauce—a dark and strongly absorbing liquid—negligible ECL emission was detected in the conventional through-solution configuration, whereas clear ECL images were obtained when observed through the transparent graphene electrode. This strategy eliminates the need for extensive sample dilution to mitigate absorption-induced signal loss, thereby extending the applicability of ECL to colored and optically dense samples and representing a critical advancement toward point-of-care testing of complex real-world solutions.
- 30 October 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessElectrochemiluminescence Detection in Optically Dense Solutions Through Transparent Graphene Electrodes
Electrochemiluminescence (ECL) enables highly sensitive bioanalytical detection; however, its practical application is constrained by strong optical absorption in colored or optically dense samples, which significantly attenuates the emitted signal. In this study, we address this limitation by employing transparent graphene electrodes for enzyme-mediated ECL detection in optically dense liquids. Glutamate oxidase was immobilized in proximity to the electrode surface to catalyze the conversion of glutamate into hydrogen peroxide, which subsequently initiated luminol-based ECL. The integrated ECL intensity increased with glutamate concentration and followed a Michaelis–Menten–type relationship, confirming that the signal originated from the enzymatic reaction. When evaluated in soy sauce—a dark and strongly absorbing liquid—negligible ECL emission was detected in the conventional through-solution configuration, whereas clear ECL images were obtained when observed through the transparent graphene electrode. This strategy eliminates the need for extensive sample dilution to mitigate absorption-induced signal loss, thereby extending the applicability of ECL to colored and optically dense samples and representing a critical advancement toward point-of-care testing of complex real-world solutions.
- Open Access
- 21 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Quality Control of Graphene Field-Effect Transistor Arrays Using Slit-Scanning Raman Microscopy
Large-scale graphene films enable the integration of graphene field-effect transistor (GFET) arrays onto chips. However, the transfer characteristics display variability across the array. This significant statistical variation in graphene quality, combined with the lack of standardized protocols, poses a major challenge to commercialization. In this study, we present a rapid, extensive, and high-resolution inspection technique using slit-scanning Raman microscopy. Raman imaging of all GFETs in the arrays were performed before conducting electrical measurements. The G-band and 2D-band peak positions were used to determine the hole carrier density (nH) in the GFETs. Variations in nH values across the arrays correlated with the VDP values, a critical parameter of FET performance, validating this approach as an inspection method. Moreover, Raman peaks were tracked across 100 GFETs at different processing stages, revealing that spatial variations originated during the wet-transfer process. This method is vital for the scalable manufacturing of graphene devices.
- 21 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessQuality Control of Graphene Field-Effect Transistor Arrays Using Slit-Scanning Raman Microscopy
Large-scale graphene films enable the integration of graphene field-effect transistor (GFET) arrays onto chips. However, the transfer characteristics display variability across the array. This significant statistical variation in graphene quality, combined with the lack of standardized protocols, poses a major challenge to commercialization. In this study, we present a rapid, extensive, and high-resolution inspection technique using slit-scanning Raman microscopy. Raman imaging of all GFETs in the arrays were performed before conducting electrical measurements. The G-band and 2D-band peak positions were used to determine the hole carrier density (nH) in the GFETs. Variations in nH values across the arrays correlated with the VDP values, a critical parameter of FET performance, validating this approach as an inspection method. Moreover, Raman peaks were tracked across 100 GFETs at different processing stages, revealing that spatial variations originated during the wet-transfer process. This method is vital for the scalable manufacturing of graphene devices.
- Open Access
- 7 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Biosensing with Surface Charge Modulated Graphene Field-Effect Transistors Beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and non-functionalized GFETs into a chip, and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection (LOD) of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.
- 7 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessBiosensing with Surface Charge Modulated Graphene Field-Effect Transistors Beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and non-functionalized GFETs into a chip, and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection (LOD) of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.