Shinsuke Tani
Research Subjects
Shinsuke Tani has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Kazuhiko Matsumoto
Osaka University
3 shared publications - Masahiko Kimura
Murata Manufacturing Co., Ltd
3 shared publications - Shota Ushiba
Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan
3 shared publications - Naruto Miyakawa
Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan
2 shared publications - Takao Ono
Osaka Univ, SANKEN, Ibaraki, Osaka 5670047, Japan
2 shared publications - Tomomi Nakano
Murata Manufacturing Co., Ltd
2 shared publications
Latest Publications
- Open Access
- 21 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Quality Control of Graphene Field-Effect Transistor Arrays Using Slit-Scanning Raman Microscopy
Large-scale graphene films enable the integration of graphene field-effect transistor (GFET) arrays onto chips. However, the transfer characteristics display variability across the array. This significant statistical variation in graphene quality, combined with the lack of standardized protocols, poses a major challenge to commercialization. In this study, we present a rapid, extensive, and high-resolution inspection technique using slit-scanning Raman microscopy. Raman imaging of all GFETs in the arrays were performed before conducting electrical measurements. The G-band and 2D-band peak positions were used to determine the hole carrier density (nH) in the GFETs. Variations in nH values across the arrays correlated with the VDP values, a critical parameter of FET performance, validating this approach as an inspection method. Moreover, Raman peaks were tracked across 100 GFETs at different processing stages, revealing that spatial variations originated during the wet-transfer process. This method is vital for the scalable manufacturing of graphene devices.
- 21 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessQuality Control of Graphene Field-Effect Transistor Arrays Using Slit-Scanning Raman Microscopy
Large-scale graphene films enable the integration of graphene field-effect transistor (GFET) arrays onto chips. However, the transfer characteristics display variability across the array. This significant statistical variation in graphene quality, combined with the lack of standardized protocols, poses a major challenge to commercialization. In this study, we present a rapid, extensive, and high-resolution inspection technique using slit-scanning Raman microscopy. Raman imaging of all GFETs in the arrays were performed before conducting electrical measurements. The G-band and 2D-band peak positions were used to determine the hole carrier density (nH) in the GFETs. Variations in nH values across the arrays correlated with the VDP values, a critical parameter of FET performance, validating this approach as an inspection method. Moreover, Raman peaks were tracked across 100 GFETs at different processing stages, revealing that spatial variations originated during the wet-transfer process. This method is vital for the scalable manufacturing of graphene devices.
- Open Access
- 7 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Biosensing with Surface Charge Modulated Graphene Field-Effect Transistors Beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and non-functionalized GFETs into a chip, and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection (LOD) of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.
- 7 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessBiosensing with Surface Charge Modulated Graphene Field-Effect Transistors Beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and non-functionalized GFETs into a chip, and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection (LOD) of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.
- Open Access
Drift Suppression of Solution-Gated Graphene Field-Effect Transistors by Cation Doping for Sensing Platforms
Solution-gated graphene field-effect transistors (SG-GFETs) provide an ideal platform for sensing biomolecules owing to their high electron/hole mobilities and 2D nature. However, the transfer curve often drifts in an electrolyte solution during measurements, making it difficult to accurately estimate the analyte concentration. One possible reason for this drift is that p-doping of GFETs is gradually countered by cations in the solution, because the cations can permeate into the polymer residue and/or between graphene and SiO2 substrates. Therefore, we propose doping sufficient cations to counter p-doping of GFETs prior to the measurements. For the pre-treatment, GFETs were immersed in a 15 mM sodium chloride aqueous solution for 25 h. The pretreated GFETs showed that the charge neutrality point (CNP) drifted by less than 3 mV during 1 h of measurement in a phosphate buffer, while the non-treated GFETs showed that the CNP was severely drifted by approximately 50 mV, demonstrating a 96% reduction of the drift by the pre-treatment. X-ray photoelectron spectroscopy analysis revealed the accumulation of sodium ions in the GFETs through pre-treatment. Our method is useful for suppressing drift, thus allowing accurate estimation of the target analyte concentration.
Open AccessDrift Suppression of Solution-Gated Graphene Field-Effect Transistors by Cation Doping for Sensing Platforms
Solution-gated graphene field-effect transistors (SG-GFETs) provide an ideal platform for sensing biomolecules owing to their high electron/hole mobilities and 2D nature. However, the transfer curve often drifts in an electrolyte solution during measurements, making it difficult to accurately estimate the analyte concentration. One possible reason for this drift is that p-doping of GFETs is gradually countered by cations in the solution, because the cations can permeate into the polymer residue and/or between graphene and SiO2 substrates. Therefore, we propose doping sufficient cations to counter p-doping of GFETs prior to the measurements. For the pre-treatment, GFETs were immersed in a 15 mM sodium chloride aqueous solution for 25 h. The pretreated GFETs showed that the charge neutrality point (CNP) drifted by less than 3 mV during 1 h of measurement in a phosphate buffer, while the non-treated GFETs showed that the CNP was severely drifted by approximately 50 mV, demonstrating a 96% reduction of the drift by the pre-treatment. X-ray photoelectron spectroscopy analysis revealed the accumulation of sodium ions in the GFETs through pre-treatment. Our method is useful for suppressing drift, thus allowing accurate estimation of the target analyte concentration.