Toshikazu Ito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Toshikazu Ito has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Yoshifumi Komoike
Division of Breast and Endocrine Surgery Department of Surgery, Kindai University Faculty of Medicine, Osaka, Japan
3 shared publicationsAkira Kuwajima
Department of Health Check-Up, PL Tokyo Health Control Center, Tokyo, Japan
1 shared publication- Chihiro Ikegawa
Yamanashi PET Imaging Clinic, Chuo 409-3821, Japan
1 shared publication - Daisuke Morimoto-Ishikawa
Radiology Center, Kindai University Hospital, Osaka
1 shared publication Ei Ueno
Tsukuba International Breast Clinic, Ibaraki, Japan
1 shared publicationEriko Tohno
Tsukuba International Breast Clinic, Ibaraki, Japan
1 shared publication
Latest Publications
- Open Access
- 24 October 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (4) , 563-566
Understanding the basics and clinical applications of contrast-enhanced ultrasound for breast lesions
- 24 October 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (4) , 563-566
Open AccessUnderstanding the basics and clinical applications of contrast-enhanced ultrasound for breast lesions
- Open Access
- 23 August 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (4) , 611-625
Current status and future perspectives of contrast-enhanced ultrasound diagnosis of breast lesions
Advances in various imaging modalities for breast lesions have improved diagnostic capabilities not only for tumors but also for non-tumorous lesions. Contrast-enhanced ultrasound (CEUS) plays a crucial role not only in the differential diagnosis of breast lesions, identification of sentinel lymph nodes, and diagnosis of lymph node metastasis but also in assessing the therapeutic effects of neoadjuvant chemotherapy (NAC). In CEUS, two image interpretation approaches, i.e., qualitative analysis and quantitative analysis, are employed and applied in various clinical settings. In this paper, we review CEUS for breast lesions, including its various applications.
- 23 August 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (4) , 611-625
Open AccessCurrent status and future perspectives of contrast-enhanced ultrasound diagnosis of breast lesions
Advances in various imaging modalities for breast lesions have improved diagnostic capabilities not only for tumors but also for non-tumorous lesions. Contrast-enhanced ultrasound (CEUS) plays a crucial role not only in the differential diagnosis of breast lesions, identification of sentinel lymph nodes, and diagnosis of lymph node metastasis but also in assessing the therapeutic effects of neoadjuvant chemotherapy (NAC). In CEUS, two image interpretation approaches, i.e., qualitative analysis and quantitative analysis, are employed and applied in various clinical settings. In this paper, we review CEUS for breast lesions, including its various applications.
- 19 July 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 50 (3) , 327-329
A feature to promote better understanding of breast non-mass abnormalities
- 19 July 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 50 (3) , 327-329
A feature to promote better understanding of breast non-mass abnormalities
- Open Access
- 1 June 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 50 (3) , 331-339
The Japan Society of Ultrasonics in Medicine guidelines on non-mass abnormalities of the breast
It is possible to appropriately diagnose non-mass abnormalities by elucidating ultrasound non-mass abnormality findings and sharing the concept. If non-mass abnormalities can be diagnosed early, the number of curable cases could increase, leading to fewer breast cancer deaths. The Japan Society of Ultrasonics in Medicine (JSUM) Terminology/Diagnostic Criteria Committee has classified non-mass abnormalities into five subtypes: hypoechoic area in the mammary gland, abnormalities of the ducts, architectural distortion, multiple small cysts, and echogenic foci without a hypoechoic area. We herein define the findings for each of these subtypes and present a summary of the JSUM guidelines on non-mass abnormalities of the breast generated based on those findings.
- 1 June 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 50 (3) , 331-339
Open AccessThe Japan Society of Ultrasonics in Medicine guidelines on non-mass abnormalities of the breast
It is possible to appropriately diagnose non-mass abnormalities by elucidating ultrasound non-mass abnormality findings and sharing the concept. If non-mass abnormalities can be diagnosed early, the number of curable cases could increase, leading to fewer breast cancer deaths. The Japan Society of Ultrasonics in Medicine (JSUM) Terminology/Diagnostic Criteria Committee has classified non-mass abnormalities into five subtypes: hypoechoic area in the mammary gland, abnormalities of the ducts, architectural distortion, multiple small cysts, and echogenic foci without a hypoechoic area. We herein define the findings for each of these subtypes and present a summary of the JSUM guidelines on non-mass abnormalities of the breast generated based on those findings.
- Open Access
- 13 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1079
Organ-Specific Positron Emission Tomography Scanners for Breast Imaging: Comparison between the Performances of Prior and Novel Models
The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3–10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various β-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher β and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.
- 13 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1079
Open AccessOrgan-Specific Positron Emission Tomography Scanners for Breast Imaging: Comparison between the Performances of Prior and Novel Models
The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3–10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various β-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher β and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.