Calder Wilson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Calder Wilson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jacob Dawes
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication - Jaehyeong Park
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication - Louis Marun
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication - Matthew L. Johnston
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication - Siyuan Yu
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication - Tzu-Hsuan Chou
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication
Latest Publications
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 712-725
System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification
This paper presents an impedance measurement system-on-chip (SoC) for flow cytometry (i.e. cell counting) applications. A source-differential, three-electrode sensing scheme is used in a microfluidic flow cell for particle detection. At the front-end, a lock-in amplifier architecture is used, including a high-gain TIA with 60MHz bandwidth, passive mixers, and lowpass filters. The ac sensor signal is demodulated to extract inphase (I) and quadrature (Q) baseband components to measure complex impedance. At the back-end, the SoC includes an 8-bit level-crossing ADC (LCADC) for digitizing I/Q signals, followed by real-time digital feature extraction and linear classification for real-time cell size determination. The SoC was fabricated in a 180nm CMOS process. A measured prototype IC achieves 733 fA/$\sqrt {Hz}$ noise floor and 23 pArms input-referred noise from 1-1 kHz. Combined with a microfludic flow cell, polymer beads in solution were used as cell surrogates to demonstrate particle counting. Measured results for particle diameters of 10 μm, 6 μm, 4.5 μm and 3 μm are shown. Following offline training, the SoC demonstrated on-chip classification of 4.5 μm and 6 μm beads with a prediction accuracy of 86.16% with pre-recorded data, and 73.6% while performing real-time inline classification.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 712-725
System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification
This paper presents an impedance measurement system-on-chip (SoC) for flow cytometry (i.e. cell counting) applications. A source-differential, three-electrode sensing scheme is used in a microfluidic flow cell for particle detection. At the front-end, a lock-in amplifier architecture is used, including a high-gain TIA with 60MHz bandwidth, passive mixers, and lowpass filters. The ac sensor signal is demodulated to extract inphase (I) and quadrature (Q) baseband components to measure complex impedance. At the back-end, the SoC includes an 8-bit level-crossing ADC (LCADC) for digitizing I/Q signals, followed by real-time digital feature extraction and linear classification for real-time cell size determination. The SoC was fabricated in a 180nm CMOS process. A measured prototype IC achieves 733 fA/$\sqrt {Hz}$ noise floor and 23 pArms input-referred noise from 1-1 kHz. Combined with a microfludic flow cell, polymer beads in solution were used as cell surrogates to demonstrate particle counting. Measured results for particle diameters of 10 μm, 6 μm, 4.5 μm and 3 μm are shown. Following offline training, the SoC demonstrated on-chip classification of 4.5 μm and 6 μm beads with a prediction accuracy of 86.16% with pre-recorded data, and 73.6% while performing real-time inline classification.