WCWon Gi Chung

Won Gi Chung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Won Gi Chung has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Advances and Challenges in Wearable Sensors for Health Monitoring

    by Laís Canniatti Brazaca, Alvaro Moreno Lozano, Beatriz Mayol, Desiree Tamara Scheidt, Domenico De Fazio, Enji Kim, Gabriel Maroli, Giulio Rosati, Hatice Ceren Ates, Hui Wang, et al.

    Analytical tools may revolutionize healthcare by enabling accessible, rapid, and decentralized testing. Wearable (bio)sensors, in particular, provide frequent or continuous patient monitoring through non- to minimally invasive measurements. This approach yields unprecedented amounts of health-related information, leading to more informed clinical decision-making and closer patient follow-up. In this mega-review article, we bring together leading researchers in the field to discuss the state of the art in wearable devices for health monitoring. We begin by providing a broad overview of the field through citation network analysis. We then review the application of chemical (bio)sensors in biofluids (e.g., sweat, saliva, tears, interstitial fluid, and cerebrospinal fluid), highlighting the challenges and advantages associated with each. Subsequently, we discuss the construction of wearable devices and their main formats (e.g., smart contact lenses, textiles, mouthguards, watches/wristbands, and implantable systems). Physical sensors are addressed in a dedicated section focusing on the assessment of heart rate, blood pressure, and body temperature. The role of soft electronics in wearable devices is also examined, as these technologies are essential for enhancing user comfort and sensor reliability, which demands advances in materials science. Furthermore, we present strategies for signal acquisition and transmission, as well as approaches for on-body energy harvesting and device self-powering. The use of artificial intelligence and machine learning is then discussed as a means of enhancing analytical performance and managing the large volumes of data generated by wearable devices. Finally, business, regulatory, and ethical considerations are examined. We expect that this review will provide an overview of sensing and biosensing technologies for health-related applications, identify promising research directions, and inspire future developments.


  • Open Access

    AI-driven tripartite classification for optimizing wearable bioelectronics in depression management

    by Jakyoung Lee, Yeon-Mi Hong, Enji Kim, Hunkyu Seo, Won Gi Chung, Wonjung Park, Hayoung Song, Sumin Kim, Jang-Ung Park

    Current disease-sensing devices primarily focus on distinguishing between healthy and diseased states, effective for diagnosis but limited in guiding optimal intervention timing for prevention. We developed a tripartite framework identifying pre-disease state in depression, a reversible phase preceding irreversible onset. Using complex systems theory, we analyzed early-warning signals emerging as biological systems approach critical transitions. Continuous monitoring of nine multimodal biomarkers—spanning electrophysiological, behavioral, and biological—enabled classification into normal, pre-disease, and disease states by quantitatively defining critical points. An artificial intelligence agent classified disease states with 95.2% accuracy using multimodal data, enabled by ultrasoft neural probes for stable, low-damage recordings. Therapeutic validation with a skin-attachable wireless vagus nerve stimulator integrating soft three-dimensional electrodes demonstrated superior efficacy during pre-disease states. Subjects treated during pre-disease showed faster recovery and greater therapeutic responses, while those treated after disease onset failed to achieve full recovery. This framework provides evidence-based rationale for early intervention.


  • Open Access

    Interference haptic stimulation and consistent quantitative tactility in transparent electrotactile screen with pressure-sensitive transistors

    by Kyeonghee Lim, Jakyoung Lee, Sumin Kim, Myoungjae Oh, Chin Su Koh, Hunkyu Seo, Yeon-Mi Hong, Won Gi Chung, Jiuk Jang, Jung Ah Lim, et al.

    Integrating tactile feedback through haptic interfaces enhances experiences in virtual and augmented reality. However, electrotactile systems, which stimulate mechanoreceptors directly, often yield inconsistent tactile results due to variations in pressure between the device and the finger. In this study, we present the integration of a transparent electrotactile screen with pressure-sensitive transistors, ensuring highly consistent quantitative haptic sensations. These transistors effectively calibrate tactile variations caused by touch pressure. Additionally, we explore remote-distance tactile stimulations achieved through the interference of electromagnetic waves. We validated tactile perception using somatosensory evoked potentials, monitoring the somatosensory cortex response. Our haptic screen can stimulate diverse electrotactile sensations and demonstrate various tactile patterns, including Morse code and Braille, when integrated with portable smart devices, delivering a more immersive experience. Furthermore, interference of electric fields allows haptic stimulation to facilitate diverse stimulus positioning at lower current densities, extending the reach beyond direct contact with electrodes of our screen.


  • Three-Dimensional Electrodes of Liquid Metals for Long-Term, Wireless Cardiac Analysis and Modulation

    by Sumin Kim, Jakyoung Lee, Won Gi Chung, Yeon-Mi Hong, Wonjung Park, Jung Ah Lim, Jang-Ung Park

    Cardiovascular disease is a major public health issue, and smart diagnostic approaches play an important role in the analysis of electrocardiograms. Here, we present three-dimensional, soft electrodes of liquid metals that can be conformably attached to the surfaces of the heart and skin for long-term cardiac analysis. The fine micropillar structures of biocompatible liquid metals enable precise targeting to small tissue areas, allowing for spatiotemporal mapping and modulation of cardiac electrical activity with high resolution. The low mechanical modulus of these liquid-metal electrodes not only helps avoid inflammatory responses triggered by modulus mismatch between the tissue and electrodes, but also minimizes pain when embedded in biological tissues such as the skin and heart. Furthermore, in vivo experiments with animal models and human trials demonstrate long-term and accurate monitoring of electrocardiograms over a period of 30 days.


  • Open Access

    Real-time in vivo monitoring of intraocular pressure distribution in the anterior chamber and vitreous chamber for diagnosis of glaucoma

    by Hunkyu Seo, Yeon-Mi Hong, Won Gi Chung, Wonjung Park, Jakyoung Lee, Hong Kyun Kim, Suk Ho Byeon, Dai Woo Kim, Jang-Ung Park

    Glaucoma causes irreversible vision loss due to optic nerve damage and retinal cell degeneration. Since high intraocular pressure (IOP) is a major risk factor for glaucoma development, accurate IOP measurement is crucial, especially intravitreal IOP affecting the optical nerve and cells. However, conventional methods have limits in selectively and directly detecting local retina pressure. Here, we present continuous measurements of local IOP values in the anterior chamber and vitreous chamber of living animals using minimally invasive probes with pressure-sensitive transistors. After inducing glaucoma in animal models, we compared the local IOP distribution between normal and glaucomatous eyes. We also compared IOP values detected in the cornea using tonometry measurements. Our findings revealed that glaucoma induced higher IOP in the vitreous chamber than in the anterior chamber, indicating that measuring IOP in the vitreous chamber is key to the glaucoma model. This progress offers future directions for diagnosis and treatment of glaucoma.


  • Top Cited Papers
    Open Access

    Liquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration

    by Won Gi Chung, Jiuk Jang, Gang Cui, Sanghoon Lee, Han Jeong, Haisu Kang, Hunkyu Seo, Sumin Kim, Enji Kim, Junwon Lee, et al.

    Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 μm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium–indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm−2) to elicit neural responses in the retina. Their low Young’s modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.


  • Top Cited Papers
    Open Access

    Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management

    by Hunkyu Seo, Won Gi Chung, Yong Won Kwon, Sumin Kim, Yeon-Mi Hong, Wonjung Park, Enji Kim, Jakyoung Lee, Sanghoon Lee, Moohyun Kim, et al.

    The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.


  • Materials and Structural Designs for Neural Interfaces

    by Sumin Kim, Yong Won Kwon, Hunkyu Seo, Won Gi Chung, Enji Kim, Wonjung Park, Hayoung Song, Dong Ha Lee, Jakyoung Lee, Sanghoon Lee, et al.