Ilan Eliyahu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ilan Eliyahu has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
A. Shapiro
3 shared publicationsG. Reshes
3 shared publicationsL. Oster
3 shared publicationsY.S. Horowitz
3 shared publications- Dimitry Nemirovsky
Shamoon College of Engineering, Beer-Sheva 84105, Israel
2 shared publications H. Einav
2 shared publications
Latest Publications
- 12 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 581
Kinetic simulation of the glow curve and isothermal decay in the thermoluminescence of LiF:Mg,Ti: the spatially correlated trapping center/luminescent center model
- 12 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 581
Kinetic simulation of the glow curve and isothermal decay in the thermoluminescence of LiF:Mg,Ti: the spatially correlated trapping center/luminescent center model
- 31 August 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (1-2) , 53-59
INVESTIGATION OF THE TL CHARACTERISTICS OF COMPOSITE PEAK 5 IN THE GLOW CURVE OF LIF:MG,TI (TLD-100) USING NATURALLY AND FURNACE-COOLED SAMPLES FOLLOWING THE 400°C PRE-IRRADIATION ANNEAL
The cooling rate to room temperature following the 400°C pre-irradiation anneal is known to affect the thermoluminescent properties of LiF:Mg,Ti (TLD-100) as a result of migration and clustering of defects during the cooling down process. In this investigation the dose response over an extended dose range from 0.01 to 7000 Gy in both naturally cooled and the much slower furnace-cooled samples has been measured. Glow curve deconvolution based on first-order kinetics is employed to extract the dose response of the various glow peaks. Of especial interest is the behaviour of glow peaks 4, 5a and 5 as a function of dose. The idea is to modify the supralinear dose response of peak 5 from 1 to 30 Gy to a linear behaviour. This dose range is important for clinical therapy and a linear dose response is of substantial advantage leading to both improved accuracy and precision.
- 31 August 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (1-2) , 53-59
INVESTIGATION OF THE TL CHARACTERISTICS OF COMPOSITE PEAK 5 IN THE GLOW CURVE OF LIF:MG,TI (TLD-100) USING NATURALLY AND FURNACE-COOLED SAMPLES FOLLOWING THE 400°C PRE-IRRADIATION ANNEAL
The cooling rate to room temperature following the 400°C pre-irradiation anneal is known to affect the thermoluminescent properties of LiF:Mg,Ti (TLD-100) as a result of migration and clustering of defects during the cooling down process. In this investigation the dose response over an extended dose range from 0.01 to 7000 Gy in both naturally cooled and the much slower furnace-cooled samples has been measured. Glow curve deconvolution based on first-order kinetics is employed to extract the dose response of the various glow peaks. Of especial interest is the behaviour of glow peaks 4, 5a and 5 as a function of dose. The idea is to modify the supralinear dose response of peak 5 from 1 to 30 Gy to a linear behaviour. This dose range is important for clinical therapy and a linear dose response is of substantial advantage leading to both improved accuracy and precision.
- 1 November 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 192 (2) , 196-204
KINETIC SIMULATIONS OF THE THERMOLUMINESCENCE CHARACTERISTICS OF LIF:MG, TI INCORPORATING LOCALISED AND DELOCALISED RECOMBINATION
Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impossible due to the scarcity of materials with demonstrably proven ‘single-peak’ glow curves. The delocalised models are incapable of the simulation of TL dose response linear/supralinear behaviour and the dependence of the supralinearity on particle energy. These characteristics require the incorporation of localised, nanodosimetric, recombination processes in the TL mechanisms. These investigations have simulated many of the TL characteristics of LiF:Mg, Ti in kinetic models based on a mixture of both delocalised and localised recombination.
- 1 November 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 192 (2) , 196-204
KINETIC SIMULATIONS OF THE THERMOLUMINESCENCE CHARACTERISTICS OF LIF:MG, TI INCORPORATING LOCALISED AND DELOCALISED RECOMBINATION
Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impossible due to the scarcity of materials with demonstrably proven ‘single-peak’ glow curves. The delocalised models are incapable of the simulation of TL dose response linear/supralinear behaviour and the dependence of the supralinearity on particle energy. These characteristics require the incorporation of localised, nanodosimetric, recombination processes in the TL mechanisms. These investigations have simulated many of the TL characteristics of LiF:Mg, Ti in kinetic models based on a mixture of both delocalised and localised recombination.
- 1 September 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 431, 6-11
Kinetic simulation of the effect of 3.6 eV and 4.2 eV photon excitation on the optical absorption energy spectrum of 137 Cs gamma irradiated LiF:Mg,Ti (TLD-100)
- 1 September 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 431, 6-11
Kinetic simulation of the effect of 3.6 eV and 4.2 eV photon excitation on the optical absorption energy spectrum of 137 Cs gamma irradiated LiF:Mg,Ti (TLD-100)
- 1 February 2006
- Published by Wiley in Bioelectromagnetics
- Vol. 27 (2) , 119-126
Effects of radiofrequency radiation emitted by cellular telephones on the cognitive functions of humans
The present study examined the effects of exposure to Electromagnetic Radiation emitted by a standard GSM phone at 890 MHz on human cognitive functions. This study attempted to establish a connection between the exposure of a specific area of the brain and the cognitive functions associated with that area. A total of 36 healthy right‐handed male subjects performed four distinct cognitive tasks: spatial item recognition, verbal item recognition, and two spatial compatibility tasks. Tasks were chosen according to the brain side they are assumed to activate. All subjects performed the tasks under three exposure conditions: right side, left side, and sham exposure. The phones were controlled by a base station simulator and operated at their full power. We have recorded the reaction times (RTs) and accuracy of the responses. The experiments consisted of two sections, of 1 h each, with a 5 min break in between. The tasks and the exposure regimes were counterbalanced. The results indicated that the exposure of the left side of the brain slows down the left‐hand response time, in the second—later—part of the experiment. This effect was apparent in three of the four tasks, and was highly significant in only one of the tests. The exposure intensity and its duration exceeded the common exposure of cellular phone users. Bioelectromagnetics 27:119–126, 2006.
- 1 February 2006
- Published by Wiley in Bioelectromagnetics
- Vol. 27 (2) , 119-126
Effects of radiofrequency radiation emitted by cellular telephones on the cognitive functions of humans
The present study examined the effects of exposure to Electromagnetic Radiation emitted by a standard GSM phone at 890 MHz on human cognitive functions. This study attempted to establish a connection between the exposure of a specific area of the brain and the cognitive functions associated with that area. A total of 36 healthy right‐handed male subjects performed four distinct cognitive tasks: spatial item recognition, verbal item recognition, and two spatial compatibility tasks. Tasks were chosen according to the brain side they are assumed to activate. All subjects performed the tasks under three exposure conditions: right side, left side, and sham exposure. The phones were controlled by a base station simulator and operated at their full power. We have recorded the reaction times (RTs) and accuracy of the responses. The experiments consisted of two sections, of 1 h each, with a 5 min break in between. The tasks and the exposure regimes were counterbalanced. The results indicated that the exposure of the left side of the brain slows down the left‐hand response time, in the second—later—part of the experiment. This effect was apparent in three of the four tasks, and was highly significant in only one of the tests. The exposure intensity and its duration exceeded the common exposure of cellular phone users. Bioelectromagnetics 27:119–126, 2006.