Venkata Sai Charishma Pathala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Venkata Sai Charishma Pathala has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Pvy Jayasree
Department of EECE, GITAM Institute of Technology, GITAM University, Visakhapatnam, India
3 shared publications P. V. Y. Jayasree
GITAM Institute of Technology, GITAM Deemed to be University Visakhapatnam
1 shared publication- Pappu V. Y. Jayasree
Department of EECE, Gandhi Institute of Technology and Management, Deemed to be University, India
1 shared publication
Latest Publications
- Open Access
- 25 September 2023
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 11 (3) , 836-843
Estimation of Common Mode noise and Differential Mode noise generated by DC-DC Power Converters
The study contains a review of the body of knowledge regarding differential mode (DM) and common mode (CM)noise and how they affect power converter performance. With an emphasis on practical application, this work seeks to give an estimation of differential mode (DM) and common mode (CM) noise for cutting-edge DC-DC power converters such as Zeta converters, Single Ended Primary Inductance Converters (SEPIC), and Cuk converters. Active noise separators and Differential mode noise separators are used as a measurement technique to quantify DM and CM noise, considering a number of variables including input voltage, output voltage, load current, and switching frequency. By using filtering techniques, DM and CM noise can be reduced. Both CM noise and DM noise are created by the Zeta converter at 114 dBµV and 108 dBµV, respectively. CM noise from the SEPIC converter is 119 dBµV, and DM noise is 114 dBµV. With values of CM noise 98 dBµV and DM noise 106 dBµV, Cuk converter produces less noise when compared to Zeta and SEPIC converter. The results show that power converters can generate DM and CM noise, and that this noise is over the Comité International Special des Perturbations Radioélectriques [CISPR] limit line. The conducted emission range for various electronic devices is provided by this standard. This study provides useful insights for power converter designers and engineers to optimize the performance of their systems in practical applications.
- 25 September 2023
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 11 (3) , 836-843
Open AccessEstimation of Common Mode noise and Differential Mode noise generated by DC-DC Power Converters
The study contains a review of the body of knowledge regarding differential mode (DM) and common mode (CM)noise and how they affect power converter performance. With an emphasis on practical application, this work seeks to give an estimation of differential mode (DM) and common mode (CM) noise for cutting-edge DC-DC power converters such as Zeta converters, Single Ended Primary Inductance Converters (SEPIC), and Cuk converters. Active noise separators and Differential mode noise separators are used as a measurement technique to quantify DM and CM noise, considering a number of variables including input voltage, output voltage, load current, and switching frequency. By using filtering techniques, DM and CM noise can be reduced. Both CM noise and DM noise are created by the Zeta converter at 114 dBµV and 108 dBµV, respectively. CM noise from the SEPIC converter is 119 dBµV, and DM noise is 114 dBµV. With values of CM noise 98 dBµV and DM noise 106 dBµV, Cuk converter produces less noise when compared to Zeta and SEPIC converter. The results show that power converters can generate DM and CM noise, and that this noise is over the Comité International Special des Perturbations Radioélectriques [CISPR] limit line. The conducted emission range for various electronic devices is provided by this standard. This study provides useful insights for power converter designers and engineers to optimize the performance of their systems in practical applications.
- Open Access
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Innovative measurement and noise reduction of voltage coupling in shielded cables for enhanced signal integrity
The reliable transmission of electrical signals through shielded cables in the presence of electromagnetic interference (EMI) remains a critical challenge for signal integrity. This paper presents a novel and comprehensive approach for measuring and reducing voltage coupling in shielded cables connected to a shielded room from a waveguide. Additionally, we introduce an innovative active EMI filter to effectively mitigate common-mode (CM) and differential-mode (DM) noises, thereby enhancing the overall signal quality. To address the issue of voltage coupling, an open circuit method with a transmission line is considered for the measurement of output voltage at the end of the shielded cable. In order to assess the impact of EMI on transmitted signals, we utilize a state-of-the-art noise separator that enables precise differentiation and characterization of CM and DM noise components. This analysis provides valuable insights into the overall noise profile, guiding the subsequent steps toward noise reduction. An active EMI filter was designed to effectively attenuate the unwanted noise. The filter intelligently targets and mitigates both CM and DM noises, resulting in improved signal integrity. The experimental setup encompasses a shielded room, shielded cables, a waveguide, and the equipment. The obtained output voltage from the shielded cable is 495 V. It is given as an input to the equipment (Cuk converter). The noises are generated when the input voltage is given; the noises are separated by using a noise separator. CM noise obtained at the output of an active noise separator is 118.8 dBµV. DM noise obtained at the output of a differential mode noise separator is 115.8 dBµV. With the active EMI filter, we achieve remarkable reductions in CM and DM noise levels. After adding a filter to the circuit, the noises are reduced below the limit line according to the International Special Committee on Radio Interference standard; the CM noise is 44.8 dBµV and the DM noise is 47.8 dBµV.
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Open AccessInnovative measurement and noise reduction of voltage coupling in shielded cables for enhanced signal integrity
The reliable transmission of electrical signals through shielded cables in the presence of electromagnetic interference (EMI) remains a critical challenge for signal integrity. This paper presents a novel and comprehensive approach for measuring and reducing voltage coupling in shielded cables connected to a shielded room from a waveguide. Additionally, we introduce an innovative active EMI filter to effectively mitigate common-mode (CM) and differential-mode (DM) noises, thereby enhancing the overall signal quality. To address the issue of voltage coupling, an open circuit method with a transmission line is considered for the measurement of output voltage at the end of the shielded cable. In order to assess the impact of EMI on transmitted signals, we utilize a state-of-the-art noise separator that enables precise differentiation and characterization of CM and DM noise components. This analysis provides valuable insights into the overall noise profile, guiding the subsequent steps toward noise reduction. An active EMI filter was designed to effectively attenuate the unwanted noise. The filter intelligently targets and mitigates both CM and DM noises, resulting in improved signal integrity. The experimental setup encompasses a shielded room, shielded cables, a waveguide, and the equipment. The obtained output voltage from the shielded cable is 495 V. It is given as an input to the equipment (Cuk converter). The noises are generated when the input voltage is given; the noises are separated by using a noise separator. CM noise obtained at the output of an active noise separator is 118.8 dBµV. DM noise obtained at the output of a differential mode noise separator is 115.8 dBµV. With the active EMI filter, we achieve remarkable reductions in CM and DM noise levels. After adding a filter to the circuit, the noises are reduced below the limit line according to the International Special Committee on Radio Interference standard; the CM noise is 44.8 dBµV and the DM noise is 47.8 dBµV.
- Open Access
- 26 April 2023
- Published by Faculty of Electrical Engineering, Computer Science and Information Technology Osijek in International journal of electrical and computer engineering systems
- Vol. 14 (4) , 465-471
Elimination of CM Noise from SMPS Circuit using EMI Filter
The electronic devices are exposed to external electromagnetic signals that produce an unwanted signal called noise in the circuit, which causes electromagnetic interference [EMI] problems. It occurs in two modes: radiated mode and conducted mode. In the radiation mode, the shielding technique is used for radiation mode, in conduction mode filtering technique is used. The design of an EMI filter depends upon the type of noise generated by the Switched Mode Power supply circuit [SMPS]. The SMPS circuit used in this paper is a DC-DC power converter, the Boost converter is a step-up converter and Buck converter is step down converter are considered as equipment for generation of noise, the Line Impedance Stabilization Network [LISN]is used for generating the common output impedance to the power converters, the EMI filters are designed to eliminate noise generated by the circuits. There noise generated by this power converters is Common Mode [CM] noise and Differential Mode [DM] noise. The separation of noise from the equipment is done by using a noise separator. In this paper, CM noise generated by these power converters is eliminated by designing an EMI filter called an inductor filter and a PI filter. The comparison between the LC inductor filter and the PI filter for the boost and buck converters is observed. The PI filter has better performance characteristics when compared to the inductor filter for both SMPS circuits as per the Comité International Special des Perturbations Radioélectriques [CISPR] standards. This standard gives the conducted emission range for different electronic devices.
- 26 April 2023
- Published by Faculty of Electrical Engineering, Computer Science and Information Technology Osijek in International journal of electrical and computer engineering systems
- Vol. 14 (4) , 465-471
Open AccessElimination of CM Noise from SMPS Circuit using EMI Filter
The electronic devices are exposed to external electromagnetic signals that produce an unwanted signal called noise in the circuit, which causes electromagnetic interference [EMI] problems. It occurs in two modes: radiated mode and conducted mode. In the radiation mode, the shielding technique is used for radiation mode, in conduction mode filtering technique is used. The design of an EMI filter depends upon the type of noise generated by the Switched Mode Power supply circuit [SMPS]. The SMPS circuit used in this paper is a DC-DC power converter, the Boost converter is a step-up converter and Buck converter is step down converter are considered as equipment for generation of noise, the Line Impedance Stabilization Network [LISN]is used for generating the common output impedance to the power converters, the EMI filters are designed to eliminate noise generated by the circuits. There noise generated by this power converters is Common Mode [CM] noise and Differential Mode [DM] noise. The separation of noise from the equipment is done by using a noise separator. In this paper, CM noise generated by these power converters is eliminated by designing an EMI filter called an inductor filter and a PI filter. The comparison between the LC inductor filter and the PI filter for the boost and buck converters is observed. The PI filter has better performance characteristics when compared to the inductor filter for both SMPS circuits as per the Comité International Special des Perturbations Radioélectriques [CISPR] standards. This standard gives the conducted emission range for different electronic devices.
- 19 February 2023
- Published by Springer Nature
- p. 323-338
Hardening of EMP in Shielded Enclosure for Radiated Fields
- 19 February 2023
- Published by Springer Nature
- p. 323-338
Hardening of EMP in Shielded Enclosure for Radiated Fields
- Open Access
- 1 February 2023
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 13 (1) , 9837-9842
Design of a Shielded Room against EMP Signal as per MIL-STD 461
Electromagnetic shielding is the best technique to protect equipment from the Electromagnetic Pulse (EMP) signal. This paper explains how effectively the equipment will be protected within a shielded room against EMP signals. The shielded room is designed with different points of entry used to provide electrical connections to the Equipment Under Test (EUT) in a honeycomb structure for ventilation to protect the equipment from the EMP signal. The shielded room with four points of entry and honeycomb structures is designed, analyzed theoretically, and simulated in the CST Studio. The points of entry (PoE) and the honeycomb structure are designed based on MIL-STD-461 E/F/G (by following this standard the maximum frequency of EMP signal is 100MHz). It is observed that by increasing the size of the PoE the shielding effectiveness value decreases by 20dB for perfect electrical conductor (PEC) material of 2mm thickness. It is concluded that the equipment will be more protected when it is placed nearer to the front wall or in the middle of the shielded room. The performance of the shielded room will not be affected with honeycomb structures which will provide 220dB Shielding Effectiveness (SE).
- 1 February 2023
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 13 (1) , 9837-9842
Open AccessDesign of a Shielded Room against EMP Signal as per MIL-STD 461
Electromagnetic shielding is the best technique to protect equipment from the Electromagnetic Pulse (EMP) signal. This paper explains how effectively the equipment will be protected within a shielded room against EMP signals. The shielded room is designed with different points of entry used to provide electrical connections to the Equipment Under Test (EUT) in a honeycomb structure for ventilation to protect the equipment from the EMP signal. The shielded room with four points of entry and honeycomb structures is designed, analyzed theoretically, and simulated in the CST Studio. The points of entry (PoE) and the honeycomb structure are designed based on MIL-STD-461 E/F/G (by following this standard the maximum frequency of EMP signal is 100MHz). It is observed that by increasing the size of the PoE the shielding effectiveness value decreases by 20dB for perfect electrical conductor (PEC) material of 2mm thickness. It is concluded that the equipment will be more protected when it is placed nearer to the front wall or in the middle of the shielded room. The performance of the shielded room will not be affected with honeycomb structures which will provide 220dB Shielding Effectiveness (SE).