Nuri Yucel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nuri Yucel has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Fatih Aktas
Gazi University
6 shared publications - Nureddin Dinler
Gazi Üniversitesi
5 shared publications - Salih Karaaslan
Gazi Üniversitesi
5 shared publications - Hasmet Turkoglu
Cankaya University Department of Mechanical Engineering Ankara 06790 , Turkey
2 shared publications - R. Tolga Guven
Gazi University
2 shared publications - Zeynep Aytaç
GAZİ ÜNİVERSİTES
2 shared publications
Latest Publications
- Open Access
- 18 March 2025
- Published by Türkiye Enerji Stratejileri ve Politikalari Araştirma Merkezi (TESPAM) in International Journal of Energy Studies
- Vol. 10 (1) , 1185-1202
Numerical investigation of in-cylinder swirl motion under cold start conditions in a diesel engine
The performance and efficiency of internal combustion engines, particularly diesel engines, are closely tied to the quality of air-fuel mixing and combustion processes. One of the critical factors influencing these processes is the in-cylinder airflow, specifically the swirl motion, which is the rotational movement of air around the cylinder axis. This swirl plays a pivotal role in enhancing the turbulence required for efficient fuel-air mixing, accelerating flame development, and improving overall combustion. This study shows a numerical analysis of the swirl movement within the cylinder of a diesel engine under cold starting conditions. Using computational fluid dynamics (CFD) analysis, the research evaluates the effects of various valve opening configurations on swirl intensity. The results indicate that increasing valve openings generally enhances swirl motion, improving combustion efficiency by promoting better air-fuel mixing. However, excessive swirl can negatively impact performance due to increased heat transfer and potential flame propagation issues. The study also assesses the impact of turbulence models and mesh density on the accuracy of the results, with the k-ε model providing predictions closest to experimental data. These findings contribute to optimizing engine design for improved combustion characteristics and reduced emissions.
- 18 March 2025
- Published by Türkiye Enerji Stratejileri ve Politikalari Araştirma Merkezi (TESPAM) in International Journal of Energy Studies
- Vol. 10 (1) , 1185-1202
Open AccessNumerical investigation of in-cylinder swirl motion under cold start conditions in a diesel engine
The performance and efficiency of internal combustion engines, particularly diesel engines, are closely tied to the quality of air-fuel mixing and combustion processes. One of the critical factors influencing these processes is the in-cylinder airflow, specifically the swirl motion, which is the rotational movement of air around the cylinder axis. This swirl plays a pivotal role in enhancing the turbulence required for efficient fuel-air mixing, accelerating flame development, and improving overall combustion. This study shows a numerical analysis of the swirl movement within the cylinder of a diesel engine under cold starting conditions. Using computational fluid dynamics (CFD) analysis, the research evaluates the effects of various valve opening configurations on swirl intensity. The results indicate that increasing valve openings generally enhances swirl motion, improving combustion efficiency by promoting better air-fuel mixing. However, excessive swirl can negatively impact performance due to increased heat transfer and potential flame propagation issues. The study also assesses the impact of turbulence models and mesh density on the accuracy of the results, with the k-ε model providing predictions closest to experimental data. These findings contribute to optimizing engine design for improved combustion characteristics and reduced emissions.
- 22 December 2023
- Published by Türkiye Enerji Stratejileri ve Politikalari Araştirma Merkezi (TESPAM) in International Journal of Energy Studies
- Vol. 8 (4) , 649-665
Aerodynamic analysis of car rear spoiler with computational fluid dynamics for different angles and profiles
The aim of the study is to compare the drag coefficient, downforce coefficient, and downforce created by the spoiler by analyzing them with the help of the Computational Fluid Dynamics (CFD) program at different wing profiles, different angles of attacks, and speeds. Solidworks was used to create the geometry for CFD analysis. ANSYS Fluent was used as the CFD analysis program. Two airfoil profiles BE153-055 and BE153-175, were selected for analysis to compare different airfoil profiles. Selected airfoils were placed at 10° and 20° angles of attack to compare different angel of attacks and analyzed at 30 (m/s), 50 (m/s) and 70 (m/s) velocities to compare different velocities. According to the analysis results, it was observed that downforce increased in direct proportion to the camber line, angle of attack, and speed. The highest downforce was obtained in BE153-175 airfoil, 20 degrees angle of attack, and 70 (m/s) speed.
- 22 December 2023
- Published by Türkiye Enerji Stratejileri ve Politikalari Araştirma Merkezi (TESPAM) in International Journal of Energy Studies
- Vol. 8 (4) , 649-665
Aerodynamic analysis of car rear spoiler with computational fluid dynamics for different angles and profiles
The aim of the study is to compare the drag coefficient, downforce coefficient, and downforce created by the spoiler by analyzing them with the help of the Computational Fluid Dynamics (CFD) program at different wing profiles, different angles of attacks, and speeds. Solidworks was used to create the geometry for CFD analysis. ANSYS Fluent was used as the CFD analysis program. Two airfoil profiles BE153-055 and BE153-175, were selected for analysis to compare different airfoil profiles. Selected airfoils were placed at 10° and 20° angles of attack to compare different angel of attacks and analyzed at 30 (m/s), 50 (m/s) and 70 (m/s) velocities to compare different velocities. According to the analysis results, it was observed that downforce increased in direct proportion to the camber line, angle of attack, and speed. The highest downforce was obtained in BE153-175 airfoil, 20 degrees angle of attack, and 70 (m/s) speed.
- Open Access
- 30 November 2023
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 39 (2) , 785-796
Dizel bir motorun reaktivite kontrollü sıkıştırma ateşlemeli bir motora dönüşümünde farklı oranlarda propan kullanımının ve yanma başlangıç zamanının performans, emisyon ve silindir içi yanma karakteristiklerine olan etkilerinin incelenmesi
İçten yanmalı motorlarda silindir içi yanmanın modellenmesi hala karmaşık bir konudur. Benzin veya dizel gibi geleneksel yakıtların dışındaki yakıtların performansını, yanma rejimlerini ve emisyon davranışını doğru bir şekilde tahmin etmek için daha fazla geliştirme çalışmalarına ihtiyaç vardır. Bu çalışmada, 0/1-boyutlu AVL Boost programı kullanılarak sayısal modeli doğrulamak için tam yükte dizel yanma rejimindeki deneysel veriler kullanılmıştır. Doğrulama çalışmaları sırasında Vibe 2-Zone yanma modeli kullanılmıştır. Analizler sonucunda performans ve emisyon değerleri incelendiğinde % 94’e yakın uyum olduğu görülmüştür. Dizel yanma rejiminde sayısal doğrulama yapıldıktan sonra, emme portuna propan enjeksiyonu için enjektör ilavesi ile sistemin reaktivite kontrollü sıkıştırma ateşlemeli (RCCI) motora dönüştürülmesi sağlanmıştır. Sonrasında toplam yakıt kütlesi sabit tutularak farklı propan oranlarının kullanımının ve farklı yanma başlangıç zamanının RCCI bir motorda performans, yanma karakteristiği ve emisyon değerlerine etkileri incelenmiştir. Sonuç olarak %90 propan ve %10 dizel yakıt kullanımı ile performansta %11 iyileşme sağlanırken, emisyon değerleri için de katalitik egzoz ekipmanlarının kullanımına gerek kalmadığı görülmüştür. Ayrıca performans ve emisyon değerleri için en iyi yanma başlangıç zamanının üst ölü noktadan -6 °KA sonra olduğu saptanmıştır.
- 30 November 2023
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 39 (2) , 785-796
Open AccessDizel bir motorun reaktivite kontrollü sıkıştırma ateşlemeli bir motora dönüşümünde farklı oranlarda propan kullanımının ve yanma başlangıç zamanının performans, emisyon ve silindir içi yanma karakteristiklerine olan etkilerinin incelenmesi
İçten yanmalı motorlarda silindir içi yanmanın modellenmesi hala karmaşık bir konudur. Benzin veya dizel gibi geleneksel yakıtların dışındaki yakıtların performansını, yanma rejimlerini ve emisyon davranışını doğru bir şekilde tahmin etmek için daha fazla geliştirme çalışmalarına ihtiyaç vardır. Bu çalışmada, 0/1-boyutlu AVL Boost programı kullanılarak sayısal modeli doğrulamak için tam yükte dizel yanma rejimindeki deneysel veriler kullanılmıştır. Doğrulama çalışmaları sırasında Vibe 2-Zone yanma modeli kullanılmıştır. Analizler sonucunda performans ve emisyon değerleri incelendiğinde % 94’e yakın uyum olduğu görülmüştür. Dizel yanma rejiminde sayısal doğrulama yapıldıktan sonra, emme portuna propan enjeksiyonu için enjektör ilavesi ile sistemin reaktivite kontrollü sıkıştırma ateşlemeli (RCCI) motora dönüştürülmesi sağlanmıştır. Sonrasında toplam yakıt kütlesi sabit tutularak farklı propan oranlarının kullanımının ve farklı yanma başlangıç zamanının RCCI bir motorda performans, yanma karakteristiği ve emisyon değerlerine etkileri incelenmiştir. Sonuç olarak %90 propan ve %10 dizel yakıt kullanımı ile performansta %11 iyileşme sağlanırken, emisyon değerleri için de katalitik egzoz ekipmanlarının kullanımına gerek kalmadığı görülmüştür. Ayrıca performans ve emisyon değerleri için en iyi yanma başlangıç zamanının üst ölü noktadan -6 °KA sonra olduğu saptanmıştır.
- 5 July 2023
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 26 (2) , 1025-1034
Experimental Investigation of Unsteady Flow in a Vertical Shaft Axial Flow Pump
Due to the changes in the system characteristics, pumps may have to be operated far away from the design point, such as in part-load or over-load operating points. Operating the pumps far away from the design point may cause fluctuations in the flow. As a result of the fluctuations mechanical problems in the pump structure may occur. In order to overcome the problem, the operating characteristics of the pump must be determined at part load operating conditions as well as design point operating condition. In this study, flow inside a vertical shaft axial flow pump is investigated experimentally. The experimental setup is designed and constructed for the laboratory tests. The pump which is designed and manufactured is tested in the test setup. The performance of the pump is determined by measuring the flow rate, inlet and outlet pressures, rotational speed and power input of the pump. The part load and over load operating regions are determined. Pressure variations are measured at various performance points with the piezoelectric pressure transducer placed in between impeller and diffuser blade passage. Simultaneously, comparisons are made with the vibration spectrums obtained in the pump.
- 5 July 2023
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 26 (2) , 1025-1034
Experimental Investigation of Unsteady Flow in a Vertical Shaft Axial Flow Pump
Due to the changes in the system characteristics, pumps may have to be operated far away from the design point, such as in part-load or over-load operating points. Operating the pumps far away from the design point may cause fluctuations in the flow. As a result of the fluctuations mechanical problems in the pump structure may occur. In order to overcome the problem, the operating characteristics of the pump must be determined at part load operating conditions as well as design point operating condition. In this study, flow inside a vertical shaft axial flow pump is investigated experimentally. The experimental setup is designed and constructed for the laboratory tests. The pump which is designed and manufactured is tested in the test setup. The performance of the pump is determined by measuring the flow rate, inlet and outlet pressures, rotational speed and power input of the pump. The part load and over load operating regions are determined. Pressure variations are measured at various performance points with the piezoelectric pressure transducer placed in between impeller and diffuser blade passage. Simultaneously, comparisons are made with the vibration spectrums obtained in the pump.
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 123-140
DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION
N-heptane pool fire was numerically and experimentally investigated in a 1:100 scaled metro station. Fire Dynamics Simulator (FDS v6.7.5) has been applied to investigate smoke and temperature distribution by implementing different design curves in the station. Experimental and numerical studies were performed for 10 ml n-heptane fuel under zero piston effect. To develop performance-based design and to obtain reliable fire simulation results for structures, reasonable input conditions are essential for numerical studies. The aim of the study is to select most suitable fire design curve and make the numerical study independent of the experimental results for small scale hydrocarbon pool fires. In this study, t2, tanh, Eurocode 1 (BS EN 1991-1-2), exponential, and quadratic fire curves were investigated and validated with experimental results. The numerical results obtained using FDS were validated with experimental data and good agreement was observed for all design fire curves except quadratic one. It was observed that the exponential design fire curve predicted more similarly to the experimental data over the fire duration including growth, fully developed and decay phases. Regardless of the experimental results, it was seen that the temperature distribution results obtained from the numerical study using exponential fire design curve and the radiation / turbulence parameters obtained from the literature were found to have an average of 5% difference with the experimental results. It was also seen that the t2 and tanh curves have acceptable differences of 6.92% and 9.02%, respectively, and the Eurocode HC is less suitable than the other curves with a difference of 12.17%. Therefore, it can be said that in small scale hydrocarbon pool fires, fire design can be done using exponential design curve.
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 123-140
DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION
N-heptane pool fire was numerically and experimentally investigated in a 1:100 scaled metro station. Fire Dynamics Simulator (FDS v6.7.5) has been applied to investigate smoke and temperature distribution by implementing different design curves in the station. Experimental and numerical studies were performed for 10 ml n-heptane fuel under zero piston effect. To develop performance-based design and to obtain reliable fire simulation results for structures, reasonable input conditions are essential for numerical studies. The aim of the study is to select most suitable fire design curve and make the numerical study independent of the experimental results for small scale hydrocarbon pool fires. In this study, t2, tanh, Eurocode 1 (BS EN 1991-1-2), exponential, and quadratic fire curves were investigated and validated with experimental results. The numerical results obtained using FDS were validated with experimental data and good agreement was observed for all design fire curves except quadratic one. It was observed that the exponential design fire curve predicted more similarly to the experimental data over the fire duration including growth, fully developed and decay phases. Regardless of the experimental results, it was seen that the temperature distribution results obtained from the numerical study using exponential fire design curve and the radiation / turbulence parameters obtained from the literature were found to have an average of 5% difference with the experimental results. It was also seen that the t2 and tanh curves have acceptable differences of 6.92% and 9.02%, respectively, and the Eurocode HC is less suitable than the other curves with a difference of 12.17%. Therefore, it can be said that in small scale hydrocarbon pool fires, fire design can be done using exponential design curve.
- 31 October 2021
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 41 (2) , 239-247
EFFECTS OF PREHEATER LOAD AND LOCATION ON THE CATALYTIC CONVERTER EFFICIENCY DURING COLD START AND IDLING CONDITIONS
Exhaust emissions are significant pollutants that affect urban lifestyles. There are several regulations related to the exhaust emissions of both gasoline and diesel engines. In this study, the effects of a controlled heating of the exhaust line before the catalytic converter on the converter efficiency are experimentally investigated. Experiments were conducted based on either discrete or cold start conditions. For discrete conditions, the engine was operated until it reached normal and steady state operating conditions. Then, the engine was stopped until the catalytic converter surface temperature reached the ambient temperature. The experiments were first started without additional heating and then continued with different heating loads. In the second stage, the catalytic converter behavior and conversion efficiency under cold start conditions were investigated. The exhaust gas after the exhaust manifold was preheated with different heating loads for the first 150 seconds after the start of the engine; however, the exhaust line was heated 15 s before starting the engine. The effects of the location, length and heat loads of the electrical resistances on the catalytic converter behavior were investigated. After all of the experiments, it was concluded that with the appropriate location and heating loads, for discrete operating conditions, the hydrocarbon (HC) and carbon monoxide (CO) emission conversion efficiencies reached nearly 100 % after 50 s of starting the engine. For cold start conditions, the hydrocarbon (HC) and carbon monoxide (CO) emission conversion efficiencies reached 35 % and 80 %, respectively.
- 31 October 2021
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 41 (2) , 239-247
EFFECTS OF PREHEATER LOAD AND LOCATION ON THE CATALYTIC CONVERTER EFFICIENCY DURING COLD START AND IDLING CONDITIONS
Exhaust emissions are significant pollutants that affect urban lifestyles. There are several regulations related to the exhaust emissions of both gasoline and diesel engines. In this study, the effects of a controlled heating of the exhaust line before the catalytic converter on the converter efficiency are experimentally investigated. Experiments were conducted based on either discrete or cold start conditions. For discrete conditions, the engine was operated until it reached normal and steady state operating conditions. Then, the engine was stopped until the catalytic converter surface temperature reached the ambient temperature. The experiments were first started without additional heating and then continued with different heating loads. In the second stage, the catalytic converter behavior and conversion efficiency under cold start conditions were investigated. The exhaust gas after the exhaust manifold was preheated with different heating loads for the first 150 seconds after the start of the engine; however, the exhaust line was heated 15 s before starting the engine. The effects of the location, length and heat loads of the electrical resistances on the catalytic converter behavior were investigated. After all of the experiments, it was concluded that with the appropriate location and heating loads, for discrete operating conditions, the hydrocarbon (HC) and carbon monoxide (CO) emission conversion efficiencies reached nearly 100 % after 50 s of starting the engine. For cold start conditions, the hydrocarbon (HC) and carbon monoxide (CO) emission conversion efficiencies reached 35 % and 80 %, respectively.
- 8 July 2021
- Published by Springer Nature in Sādhanā
- Vol. 46 (3) , 1-11
Experimental investigation of cold start emission using preheating system on the exhaust line at the idle conditions on a spark ignition engine
- 8 July 2021
- Published by Springer Nature in Sādhanā
- Vol. 46 (3) , 1-11
Experimental investigation of cold start emission using preheating system on the exhaust line at the idle conditions on a spark ignition engine
- 1 March 2020
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 23 (1) , 231-239
Development of a Design Methodology for a Centrifugal Compressor with the Utilization of CFD
Centrifugal compressors are widely used for several purposes in many industries. Aero defense industry uses these compressors in the engines of several structures. In the present study, the centrifugal compressor of a mini jet engine is designed with the utilization of Computational Fluid Dynamics (CFD) tools with the methodology developed. The designed compressor is manufactured and its tests were conducted using an engine that is being utilized commercially. The performance parameters of the designed compressor and the results obtained from the engine were compared and presented. The specifications of the designed compressor was determined in the light of the requirements of the test engine. It was observed that the obtained mass flow rate (0.678 kg/s), pressure ratio (4.6135) and the efficiency (92.38%) values are within the limits of the design specifications and the although there is a slight difference between the results of the CFD analyses and the experiments, the trends of the curves are consistent with each other.
- 1 March 2020
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 23 (1) , 231-239
Development of a Design Methodology for a Centrifugal Compressor with the Utilization of CFD
Centrifugal compressors are widely used for several purposes in many industries. Aero defense industry uses these compressors in the engines of several structures. In the present study, the centrifugal compressor of a mini jet engine is designed with the utilization of Computational Fluid Dynamics (CFD) tools with the methodology developed. The designed compressor is manufactured and its tests were conducted using an engine that is being utilized commercially. The performance parameters of the designed compressor and the results obtained from the engine were compared and presented. The specifications of the designed compressor was determined in the light of the requirements of the test engine. It was observed that the obtained mass flow rate (0.678 kg/s), pressure ratio (4.6135) and the efficiency (92.38%) values are within the limits of the design specifications and the although there is a slight difference between the results of the CFD analyses and the experiments, the trends of the curves are consistent with each other.
- 1 December 2019
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 22 (4) , 967-977
Farklı Oranlarda Etanol ve Metanol Katkısının Tam Yük Altında Dört Silindirli Dizel Bir Motorun Performans ve Emisyon Değerlerine Olan Etkilerinin Sayısal Olarak İncelenmesi
Dizel motorlarda farklı oranlarda biyodizel yakıt kullanılması belirli motor çalışma koşullarında fazla performans kayıplarına yol açmadan egzoz emisyonlarının azaltılması için oldukça iyi bir yöntemdir. Birçok ülkede ise %5 biyodizel yakıt katkısı zorunlu hale gelmiştir ve bu oran bazı ülkelerde çok daha fazladır. Bu çalışmada da dört silindirli dizel bir motorda %5, %10 ve %15 etanol ve metanol katkısının motor performansı ve emisyonlar üzerine olan etkileri AVL Boost v2018.1 yazılımı kullanılarak incelenmiştir. Analizler neticesinde elde edilen sonuçlar değerlendirilecek olursa; %5, %10 ve %15 hacimsel oranlarındaki etanol katkısında saf dizel yakıt kullanımına göre güçteki düşüş oranları sırasıyla maksimum %5, %4 ve %5 iken, aynı hacimsel orandaki metanol katkılı yakıt karışımında ise bu oranlar %5, %5 ve %8 olmaktadır. Benzer şekilde NOx oluşumunda etanol katkısı ile azalma oranları maksimum %25, %27 ve %28 değerlerini alırken bu oran metanol katkısı ile %27, %28 ve %30 şeklinde gerçekleşmiştir. İs oluşumunda ise hem etanol hem de metanol kullanımında hıza bağlı olarak değişken bir davranış gözlenmiştir.
- 1 December 2019
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 22 (4) , 967-977
Farklı Oranlarda Etanol ve Metanol Katkısının Tam Yük Altında Dört Silindirli Dizel Bir Motorun Performans ve Emisyon Değerlerine Olan Etkilerinin Sayısal Olarak İncelenmesi
Dizel motorlarda farklı oranlarda biyodizel yakıt kullanılması belirli motor çalışma koşullarında fazla performans kayıplarına yol açmadan egzoz emisyonlarının azaltılması için oldukça iyi bir yöntemdir. Birçok ülkede ise %5 biyodizel yakıt katkısı zorunlu hale gelmiştir ve bu oran bazı ülkelerde çok daha fazladır. Bu çalışmada da dört silindirli dizel bir motorda %5, %10 ve %15 etanol ve metanol katkısının motor performansı ve emisyonlar üzerine olan etkileri AVL Boost v2018.1 yazılımı kullanılarak incelenmiştir. Analizler neticesinde elde edilen sonuçlar değerlendirilecek olursa; %5, %10 ve %15 hacimsel oranlarındaki etanol katkısında saf dizel yakıt kullanımına göre güçteki düşüş oranları sırasıyla maksimum %5, %4 ve %5 iken, aynı hacimsel orandaki metanol katkılı yakıt karışımında ise bu oranlar %5, %5 ve %8 olmaktadır. Benzer şekilde NOx oluşumunda etanol katkısı ile azalma oranları maksimum %25, %27 ve %28 değerlerini alırken bu oran metanol katkısı ile %27, %28 ve %30 şeklinde gerçekleşmiştir. İs oluşumunda ise hem etanol hem de metanol kullanımında hıza bağlı olarak değişken bir davranış gözlenmiştir.
- 25 August 2018
- Published by Gazi Publishing in Gazi Journal of Engineering Sciences
- Vol. 4 (2) , 108-114
ONE-DIMENSIONAL MODELING OF CATALYTIC CONVERTER IN COLD START CONDITIONS
- 25 August 2018
- Published by Gazi Publishing in Gazi Journal of Engineering Sciences
- Vol. 4 (2) , 108-114
ONE-DIMENSIONAL MODELING OF CATALYTIC CONVERTER IN COLD START CONDITIONS