Tianyi Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tianyi Shi has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Junhao Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
8 shared publications - Xutao Han
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
8 shared publications - Zhaoyu Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
5 shared publications - Haotian Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
3 shared publications Bo Niu
Electric Power Research Institute, Ningxia Power Grid Company Ltd., Yinchuan, China
2 shared publications- Huan Chen
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications
Latest Publications
- Open Access
Study on the Impact of the Synergistic Effect of Alternating Electric Field and Mechanical Vibration on the Jumping Characteristics of Particles Defects in GIS
The residual sub-millimeter metal particles in gas-insulated metal enclosed switchgear (GIS) and gas-insulated transmission lines (GILs) are significant factors that trigger insulation failures. During actual operation, these particles not only endure the action of alternating electric fields but also are continuously stimulated by mechanical vibrations. Current research mostly focuses on the behavior of millimeter-sized particles under a single physical field, lacking in-depth understanding of the jumping characteristics of sub-millimeter-scale particles under the combined action of alternating electric fields and mechanical vibrations. This paper has built a collaborative action test platform and constructed a spherical-bowl-shaped electrode defect model. It systematically studied the jumping behavior, motion evolution, and local discharge characteristics of 20-mesh and 40-mesh irregular aluminum particles under the combined action of different voltages (0–7 kV) and mechanical vibrations (amplitude 0.01–0.1 mm, frequency 10–100 Hz). The results show that mechanical vibrations provide initial kinetic energy for the particles, significantly reducing the threshold for jumping, and are the key initiating factor in the collaborative action; in the low-voltage stage, vibration dominates the jumping behavior, while in the high-voltage stage, the electric field dominates the motion evolution; and under dual stimulation, the jumping area of the particles is wider and the motion forms are more diverse (such as flying-flying motion, vertical state, pile-up excitation, etc.), and the starting voltage of discharge is significantly reduced, the discharge repetition rate increases with the increase in vibration intensity and voltage, and is closely related to the particle size. This paper reveals the uniqueness of particle motion and discharge under the collaborative action, providing a theoretical basis for the assessment of multi-physical field states and fault prediction of GIS/GIL.
Open AccessStudy on the Impact of the Synergistic Effect of Alternating Electric Field and Mechanical Vibration on the Jumping Characteristics of Particles Defects in GIS
The residual sub-millimeter metal particles in gas-insulated metal enclosed switchgear (GIS) and gas-insulated transmission lines (GILs) are significant factors that trigger insulation failures. During actual operation, these particles not only endure the action of alternating electric fields but also are continuously stimulated by mechanical vibrations. Current research mostly focuses on the behavior of millimeter-sized particles under a single physical field, lacking in-depth understanding of the jumping characteristics of sub-millimeter-scale particles under the combined action of alternating electric fields and mechanical vibrations. This paper has built a collaborative action test platform and constructed a spherical-bowl-shaped electrode defect model. It systematically studied the jumping behavior, motion evolution, and local discharge characteristics of 20-mesh and 40-mesh irregular aluminum particles under the combined action of different voltages (0–7 kV) and mechanical vibrations (amplitude 0.01–0.1 mm, frequency 10–100 Hz). The results show that mechanical vibrations provide initial kinetic energy for the particles, significantly reducing the threshold for jumping, and are the key initiating factor in the collaborative action; in the low-voltage stage, vibration dominates the jumping behavior, while in the high-voltage stage, the electric field dominates the motion evolution; and under dual stimulation, the jumping area of the particles is wider and the motion forms are more diverse (such as flying-flying motion, vertical state, pile-up excitation, etc.), and the starting voltage of discharge is significantly reduced, the discharge repetition rate increases with the increase in vibration intensity and voltage, and is closely related to the particle size. This paper reveals the uniqueness of particle motion and discharge under the collaborative action, providing a theoretical basis for the assessment of multi-physical field states and fault prediction of GIS/GIL.
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3533-3541
Metal Particle Movement and Induced Partial Discharge Under AC Voltages Superimposed Mechanical Vibration in GIS
Under the combined influence of AC voltages and mechanical vibration, metal particles in gas-insulated switchgear (GIS) exhibit complex movement and induce partial discharge (PD), significantly compromising the safe and stable operation of electrical equipment. In this study, a scaled model of a 330 kV GIS was developed, and an experimental platform integrating AC voltage and steady-state mechanical vibration was constructed. Three distinct particle shapes—spherical, flaky, and linear—were selected, encompassing a total of 18 particle types. The initiation-extinction characteristics were analyzed, and the movement behavior of particles throughout the development stage was described. An AE-vibration combined sensor and a PD detector were used to record discharge signals, from which the PD repetition rate, acoustic flight pattern, and maximum apparent PD amplitudes were obtained. Building on force analysis and charging theory, a method for using flight coefficient rf to quantitatively evaluate particle motion was proposed, and its validity was strongly supported by experimental results. This work provides a detailed examination of metal particle movement and induced partial discharge under AC voltages superimposed mechanical vibration, offering insights that may aid in defect detection and condition assessment of GIS equipment.
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3533-3541
Metal Particle Movement and Induced Partial Discharge Under AC Voltages Superimposed Mechanical Vibration in GIS
Under the combined influence of AC voltages and mechanical vibration, metal particles in gas-insulated switchgear (GIS) exhibit complex movement and induce partial discharge (PD), significantly compromising the safe and stable operation of electrical equipment. In this study, a scaled model of a 330 kV GIS was developed, and an experimental platform integrating AC voltage and steady-state mechanical vibration was constructed. Three distinct particle shapes—spherical, flaky, and linear—were selected, encompassing a total of 18 particle types. The initiation-extinction characteristics were analyzed, and the movement behavior of particles throughout the development stage was described. An AE-vibration combined sensor and a PD detector were used to record discharge signals, from which the PD repetition rate, acoustic flight pattern, and maximum apparent PD amplitudes were obtained. Building on force analysis and charging theory, a method for using flight coefficient rf to quantitatively evaluate particle motion was proposed, and its validity was strongly supported by experimental results. This work provides a detailed examination of metal particle movement and induced partial discharge under AC voltages superimposed mechanical vibration, offering insights that may aid in defect detection and condition assessment of GIS equipment.
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1391-1399
Motion and Discharge Characteristics of Mixed Submillimeter Metal Particles and Diverse Insulating Impurities Under AC Voltages
Submillimeter metal particles and insulating impurities are introduced during the operation of gas insulated switchgear (GIS), forming mixed particles that pose localized insulation weaknesses and compromise dielectric integrity. This study investigates the motion and discharge behaviors of such mixed particles and evaluates their impact on insulation performance. An experimental platform combining an AC voltage source with a simultaneous motion and partial discharge (PD) detection system is developed. Metal particles are mixed with five representative impurities, including adsorbent powder, closing resistor powder, glass fibers, insulating paint flakes, and rubber granules. Their motion and discharge characteristics are systematically recorded and analyzed. Polarization effects and charge accumulation are considered in interpreting the observed behaviors. The relative threat levels are evaluated using onset voltage, phase-resolved PD (PRPD) patterns, maximum PD amplitude, and PD repetition rate. Results show that mixing with adsorbent powder reduces discharge risk, reflected by a low comprehensive threat score of S = 0.1495. In contrast, other impurities increase the risk to varying degrees: closing resistor powder and insulating paint flakes cause mild effects with scores of 0.4287 and 0.3856, respectively; rubber granules have a moderate impact with S = 0.6415; while glass fibers pose the greatest threat with a score of 1.0. These conclusions provide a theoretical basis for early insulation defect detection in GIS.
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1391-1399
Motion and Discharge Characteristics of Mixed Submillimeter Metal Particles and Diverse Insulating Impurities Under AC Voltages
Submillimeter metal particles and insulating impurities are introduced during the operation of gas insulated switchgear (GIS), forming mixed particles that pose localized insulation weaknesses and compromise dielectric integrity. This study investigates the motion and discharge behaviors of such mixed particles and evaluates their impact on insulation performance. An experimental platform combining an AC voltage source with a simultaneous motion and partial discharge (PD) detection system is developed. Metal particles are mixed with five representative impurities, including adsorbent powder, closing resistor powder, glass fibers, insulating paint flakes, and rubber granules. Their motion and discharge characteristics are systematically recorded and analyzed. Polarization effects and charge accumulation are considered in interpreting the observed behaviors. The relative threat levels are evaluated using onset voltage, phase-resolved PD (PRPD) patterns, maximum PD amplitude, and PD repetition rate. Results show that mixing with adsorbent powder reduces discharge risk, reflected by a low comprehensive threat score of S = 0.1495. In contrast, other impurities increase the risk to varying degrees: closing resistor powder and insulating paint flakes cause mild effects with scores of 0.4287 and 0.3856, respectively; rubber granules have a moderate impact with S = 0.6415; while glass fibers pose the greatest threat with a score of 1.0. These conclusions provide a theoretical basis for early insulation defect detection in GIS.
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3564-3571
Effect of Wind-Blown Sand on Switching Impulse Discharge Characteristics of Long Air Gaps in High-Altitude Environments
In high-altitude regions, sandstorms frequently occur along power transmission lines, posing significant risks to the safe and stable operation of power systems. Understanding the impact of sandstorms on the switching impulse discharge characteristics of long air gaps in such environments is therefore crucial. This study employed theoretical analysis and field surveys to identify wind velocity, charge-to-mass ratio, and particle size as key parameters for determining experimental conditions. A sandstorm simulation device was developed to create a controlled environment, complemented by a switching impulse test platform to investigate the discharge characteristics of rod-rod and rod-plate air gaps under high-altitude conditions. High-speed camera was used to capture the discharge development process in rod-plate air gaps, focusing on discharge initiation delay (DID), discharge propagation velocity (DPV), leader discharge channel diameter (LDCD), and streamer branching angle (SBA). Experimental, theoretical, and microscopic observation results consistently indicate that while sandstorms may influence the discharge process through electric field distortion, they have limited impact on the dominant factors governing breakdown characteristics. The findings provide valuable insights for improving the insulation design and protection of transmission lines in high-altitude regions subject to sandstorm exposure.
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3564-3571
Effect of Wind-Blown Sand on Switching Impulse Discharge Characteristics of Long Air Gaps in High-Altitude Environments
In high-altitude regions, sandstorms frequently occur along power transmission lines, posing significant risks to the safe and stable operation of power systems. Understanding the impact of sandstorms on the switching impulse discharge characteristics of long air gaps in such environments is therefore crucial. This study employed theoretical analysis and field surveys to identify wind velocity, charge-to-mass ratio, and particle size as key parameters for determining experimental conditions. A sandstorm simulation device was developed to create a controlled environment, complemented by a switching impulse test platform to investigate the discharge characteristics of rod-rod and rod-plate air gaps under high-altitude conditions. High-speed camera was used to capture the discharge development process in rod-plate air gaps, focusing on discharge initiation delay (DID), discharge propagation velocity (DPV), leader discharge channel diameter (LDCD), and streamer branching angle (SBA). Experimental, theoretical, and microscopic observation results consistently indicate that while sandstorms may influence the discharge process through electric field distortion, they have limited impact on the dominant factors governing breakdown characteristics. The findings provide valuable insights for improving the insulation design and protection of transmission lines in high-altitude regions subject to sandstorm exposure.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Smart Combined Wireless Sensor Network for Vibration and AE Signals Measurement
Mechanical and insulation defects can lead to severe faults in power equipment, making it essential to conduct a comprehensive and accurate fusion diagnosis. Vibration and acoustic emission (AE) are two effective ways to detect the above two defects. This paper proposes and develops a reliable smart vibration and AE combined wireless sensor network (WSN), featuring both low cost and power consumption, which is suitable to detect and monitor the power equipment’s mechanical and insulation conditions. Firstly, the combined sensor is designed and the feasibility is validated by simulation, then the circuit system is designed in order to sample and process analog signals, perform edge computing, self-calibrate impedance and transmit wireless data. The calibartion and consumption tests are carried out to verify the combined measurement performance and reliable smart sensing. Then, a combined vibration and AE WSN is designed and established, enabling efficient sensor control. Fixed and mobile clients are proposed to support monitoring for various applications. Additionally, laboratory experiments demonstrate the sensor’s ability to synchronously measure vibration and partial discharge (PD), a novel vibration-AE amplitude graph is presented to reflect the correlation between vibration and PD. The proposed WSN has been deployed in an actual GIS substation, it is able to detect an apparent abnormal vibration on phase-B of the voltage transformer chamber due to a poor electrical contact defect. This paper presents a reliable and effective wireless sensing approach for the distributed fusion detection and diagnosis of both mechanical and insulation conditions of power equipment, offering a feasible solution for industrial automated measurement.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Smart Combined Wireless Sensor Network for Vibration and AE Signals Measurement
Mechanical and insulation defects can lead to severe faults in power equipment, making it essential to conduct a comprehensive and accurate fusion diagnosis. Vibration and acoustic emission (AE) are two effective ways to detect the above two defects. This paper proposes and develops a reliable smart vibration and AE combined wireless sensor network (WSN), featuring both low cost and power consumption, which is suitable to detect and monitor the power equipment’s mechanical and insulation conditions. Firstly, the combined sensor is designed and the feasibility is validated by simulation, then the circuit system is designed in order to sample and process analog signals, perform edge computing, self-calibrate impedance and transmit wireless data. The calibartion and consumption tests are carried out to verify the combined measurement performance and reliable smart sensing. Then, a combined vibration and AE WSN is designed and established, enabling efficient sensor control. Fixed and mobile clients are proposed to support monitoring for various applications. Additionally, laboratory experiments demonstrate the sensor’s ability to synchronously measure vibration and partial discharge (PD), a novel vibration-AE amplitude graph is presented to reflect the correlation between vibration and PD. The proposed WSN has been deployed in an actual GIS substation, it is able to detect an apparent abnormal vibration on phase-B of the voltage transformer chamber due to a poor electrical contact defect. This paper presents a reliable and effective wireless sensing approach for the distributed fusion detection and diagnosis of both mechanical and insulation conditions of power equipment, offering a feasible solution for industrial automated measurement.
- 24 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2460-2468
Movement Behavior and Discharge Characteristics of Submillimeter Metal Particles Under AC Voltages Superimposed Mechanical Vibration
Submillimeter metal particles are inevitably introduced during the manufacture, transportation, installation, and operation of gas insulated switchgear (GIS). These particles can move and discharge under the influence of AC voltage and mechanical vibration (MV), significantly compromising GIS insulation performance. Therefore, a comprehensive understanding of the behavior and characteristics of submillimeter metal particles under these superimposed conditions is crucial. In this study, a multisource experiment platform is established with voltage and vibration sources to observe particle movement and detect discharge signals. Results indicate that particle motion can be divided into an initial stage and a development stage, with unique periodic motion induced by vibration observed in the development stage. Furthermore, superimposed vibration reduces the maximum partial discharge (PD) amplitude, while the mean PD amplitude remains relatively unchanged. The PD repetition rate is initially enhanced and subsequently suppressed. Considering Maxwell–Wagner relaxation mechanism, a possible explanation for the observed phenomena was proposed. This study is of great interest for understanding the movement behavior and discharge characteristic of submillimeter metal particles in GIS.
- 24 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2460-2468
Movement Behavior and Discharge Characteristics of Submillimeter Metal Particles Under AC Voltages Superimposed Mechanical Vibration
Submillimeter metal particles are inevitably introduced during the manufacture, transportation, installation, and operation of gas insulated switchgear (GIS). These particles can move and discharge under the influence of AC voltage and mechanical vibration (MV), significantly compromising GIS insulation performance. Therefore, a comprehensive understanding of the behavior and characteristics of submillimeter metal particles under these superimposed conditions is crucial. In this study, a multisource experiment platform is established with voltage and vibration sources to observe particle movement and detect discharge signals. Results indicate that particle motion can be divided into an initial stage and a development stage, with unique periodic motion induced by vibration observed in the development stage. Furthermore, superimposed vibration reduces the maximum partial discharge (PD) amplitude, while the mean PD amplitude remains relatively unchanged. The PD repetition rate is initially enhanced and subsequently suppressed. Considering Maxwell–Wagner relaxation mechanism, a possible explanation for the observed phenomena was proposed. This study is of great interest for understanding the movement behavior and discharge characteristic of submillimeter metal particles in GIS.
- Open Access
Initial Characteristics of Submillimeter Metal Particles in GIS under Impact Vibration
As a critical component within power systems, Gas Insulated Switchgear (GIS) is notably susceptible to insulation degradation due to submillimeter metal particles, compromising its operational safety and stability. Moreover, impact vibrations induced by circuit breaker operations can dislodge particles that typically adhere to the interior walls, causing them to become airborne and thereby intensifying their movement and discharge activities. To investigate this phenomenon, this study establishes a testing platform where alternating current (AC) voltage is superimposed with impact vibration. A camera system, interfaced with an upper computer, is used to capture the real-time motion behavior of the particles. This study focuses on characterizing the initial movement of submillimeter metal particles of varying sizes under the influence of impact vibration by analyzing critical voltages, such as the initial lift-off voltage, stable jumping voltage, and extinction voltage. Furthermore, the effects of introducing large, centimeter-scale spherical metal and rubber particles on these initial characteristics are examined. The findings provide crucial insights into the initial behavior of submillimeter metal particles in GIS, particularly in relation to circuit breaker operations.
Open AccessInitial Characteristics of Submillimeter Metal Particles in GIS under Impact Vibration
As a critical component within power systems, Gas Insulated Switchgear (GIS) is notably susceptible to insulation degradation due to submillimeter metal particles, compromising its operational safety and stability. Moreover, impact vibrations induced by circuit breaker operations can dislodge particles that typically adhere to the interior walls, causing them to become airborne and thereby intensifying their movement and discharge activities. To investigate this phenomenon, this study establishes a testing platform where alternating current (AC) voltage is superimposed with impact vibration. A camera system, interfaced with an upper computer, is used to capture the real-time motion behavior of the particles. This study focuses on characterizing the initial movement of submillimeter metal particles of varying sizes under the influence of impact vibration by analyzing critical voltages, such as the initial lift-off voltage, stable jumping voltage, and extinction voltage. Furthermore, the effects of introducing large, centimeter-scale spherical metal and rubber particles on these initial characteristics are examined. The findings provide crucial insights into the initial behavior of submillimeter metal particles in GIS, particularly in relation to circuit breaker operations.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Fast Self-Calibration Method for Piezoelectric Sensors Excited by Pseudorandom M-Sequence
Piezoelectric element is the most critical component of a piezoelectric sensor, commonly applied for defect detection of electrical equipment. To ensure the sensor work stably and reliably, impedance and sensitivity response curves should be calibrated periodically with specific technical platforms in laboratory to evaluate the sensor’s performance and characteristics. This is costly, time-consuming and inconvenient for industrial measurements. Pseudorandom M-sequence is a kind of binary signal that exhibits statistical characteristics similar to white noise. This paper proposes a fast self-calibration method based on pseudorandom M-sequence, which is suitable for acquiring the impedance and sensitivity response curves of piezoelectric sensors. The clock pulse frequency of M-sequence can be adjusted to match the calibration band. The simulation and experimental results confirm that this method is feasible, reliable and efficient in terms of both power and time consumption, requiring a few milliseconds and approximately 10 mW for a single calibration. The method was successfully applied in a commercial AE sensor and a recently-developed wireless piezoelectric sensor. This work provides a novel solution for the self-calibration of smart piezoelectric sensors.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Fast Self-Calibration Method for Piezoelectric Sensors Excited by Pseudorandom M-Sequence
Piezoelectric element is the most critical component of a piezoelectric sensor, commonly applied for defect detection of electrical equipment. To ensure the sensor work stably and reliably, impedance and sensitivity response curves should be calibrated periodically with specific technical platforms in laboratory to evaluate the sensor’s performance and characteristics. This is costly, time-consuming and inconvenient for industrial measurements. Pseudorandom M-sequence is a kind of binary signal that exhibits statistical characteristics similar to white noise. This paper proposes a fast self-calibration method based on pseudorandom M-sequence, which is suitable for acquiring the impedance and sensitivity response curves of piezoelectric sensors. The clock pulse frequency of M-sequence can be adjusted to match the calibration band. The simulation and experimental results confirm that this method is feasible, reliable and efficient in terms of both power and time consumption, requiring a few milliseconds and approximately 10 mW for a single calibration. The method was successfully applied in a commercial AE sensor and a recently-developed wireless piezoelectric sensor. This work provides a novel solution for the self-calibration of smart piezoelectric sensors.
- 5 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
A Novel IEPE AE-Vibration-Temperature-Combined Intelligent Sensor for Defect Detection of Power Equipment
Insulation and mechanical defects are the main reasons of the power equipment fault, the former could generate partial discharge (PD) which can be detected by acoustic emission (AE) sensor, the other one can be evaluated by vibration and temperature variation. However, the two defects are detected and analyzed independently in traditional detection, the importance of multi-signal interaction and fusion analysis is ignored. To realize multi-signal synchronous detection and associated analysis, and improve the accuracy and efficiency of state evaluation of power equipment, a novel integrated electronics piezoelectric (IEPE) AE-vibration-temperature combined intelligent sensor is proposed and developed in this paper. Reasonable structure design and components customization enable the sensor to acquire signals simultaneously. Meanwhile, integrated transducer electronic data sheet (TEDS) and data processing circuit intelligentize the combined sensor. The primary detection parameters of the sensor are acquired in the calibration experiments. In PD, vibration and temperature joint experiment, it is verified that the combined sensor is more sensitive and multifunctional. Besides, a new fusion analysis diagram, vibration-phase resolved partial discharge (V-PRPD), is proposed to characterise the correlation between PD and vibration.
- 5 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
A Novel IEPE AE-Vibration-Temperature-Combined Intelligent Sensor for Defect Detection of Power Equipment
Insulation and mechanical defects are the main reasons of the power equipment fault, the former could generate partial discharge (PD) which can be detected by acoustic emission (AE) sensor, the other one can be evaluated by vibration and temperature variation. However, the two defects are detected and analyzed independently in traditional detection, the importance of multi-signal interaction and fusion analysis is ignored. To realize multi-signal synchronous detection and associated analysis, and improve the accuracy and efficiency of state evaluation of power equipment, a novel integrated electronics piezoelectric (IEPE) AE-vibration-temperature combined intelligent sensor is proposed and developed in this paper. Reasonable structure design and components customization enable the sensor to acquire signals simultaneously. Meanwhile, integrated transducer electronic data sheet (TEDS) and data processing circuit intelligentize the combined sensor. The primary detection parameters of the sensor are acquired in the calibration experiments. In PD, vibration and temperature joint experiment, it is verified that the combined sensor is more sensitive and multifunctional. Besides, a new fusion analysis diagram, vibration-phase resolved partial discharge (V-PRPD), is proposed to characterise the correlation between PD and vibration.