    A size‐adaptive RF coil for MRI of the pediatric human brain at 7 T

    by Pedram Yazdanbakhsh, Marcus J. Couch, Christian Sprang, Kyle M. Gilbert, Sajjad Feizollah, Christine L. Tardif, David A. Rudko

    Purpose: The purpose of this work was to design and build a size‐adaptive pediatric RF head coil for 7 T neuroimaging. The coil can be safely applied for imaging children 4–9 years old.Methods: The pediatric head coil incorporates eight, transmit dipole elements for operation in parallel transmit (pTx) mode. The receive architecture is comprised of a 32‐channel conformal, size‐adaptive receive array. Receive elements were arranged into five sections of a mechanically adjustable 3D printed head former, allowing adjustment of the receive array according to child head size. The transmit coil was carefully simulated to calculate specific absorption rate (SAR) and B1+ efficiency. Coil performance was then evaluated with a pediatric head phantom at both the largest and smallest dimensions of the receive former. In vivo imaging was carried out in 3 pediatric subjects (aged 5, 6, and 9 years old) to acquire B1+ field maps and anatomical MP2RAGE images.Results: A comparison of simulated and experimental B1+ performance in the pediatric head phantom was used to validate SAR models and to demonstrate that the coil was safe for pediatric imaging. The SNR performance in the pediatric phantom was improved by adjusting the position of the receive array to the smallest possible position. The in vivo B1+ efficiency agreed with expectations, and the coil provided precise anatomical images of the brain.Conclusions: The proposed size‐adaptive coil enables safe, high‐quality imaging of children at 7 T, with a range of ages and head sizes. Accurate SAR modeling enabled imaging using both combined circularly polarized and dynamic pTx modes.


  • Open Access

    3D MERMAID : 3D Multi‐shot enhanced recovery motion artifact insensitive diffusion for submillimeter, multi‐shell, and SNR ‐efficient diffusion imaging

    by Sajjad Feizollah, Christine L. Tardif

    Purpose: To enhance SNR per unit time of diffusion MRI to enable high spatial resolution and extensive q‐sampling in a feasible scan time on clinical scanners. Methods: 3D multi‐shot enhanced recovery motion‐insensitive diffusion (MERMAID) consists of a whole brain nonselective 3D multi‐shot spin‐echo sequence with an inversion pulse immediately before the excitation pulse to enhance the recovery of longitudinal magnetization. The excitation flip angle is reduced to the Ernst angle. The sequence includes a trajectory using radially batched internal navigator echoes (TURBINE) readout, where a 3D projection of the FOV is acquired at a different radial angle in every shot. An image‐based phase‐correction method combined with compressed sensing image reconstruction was developed to correct phase errors between shots. The performance of the 3D MERMAID sequence was investigated using Bloch simulations as well as phantom and human scans at 3 T and then compared to a typical multi‐slice 2D spin‐echo sequence. Results: Improvements in SNR per unit time of 70%–240% were observed in phantom and human scans when using 3D MERMAID compared to a single‐slice 2D spin‐echo sequence. This SNR per unit time improvement allowed scans to be acquired at a nominal isotropic resolution of 0.74 mm and a total of 112 directions across four shells ( b = 150, 300, 1000, 2000 s/mm 2 ) in 37 min on a clinical scanner. Conclusion: The 3D MERMAID sequence was shown to significantly improve SNR per unit time compared to multi‐slice 2D and 3D diffusion sequences. This SNR improvement allows for shorter scan times and higher spatial and angular resolutions on clinical scanners.


  • Open Access

    High-resolution diffusion-weighted imaging at 7 Tesla: single-shot readout trajectories and their impact on signal-to-noise ratio, spatial resolution and accuracy

    by Sajjad Feizollah, Christine L. Tardif

    Diffusion MRI (dMRI) is a valuable imaging technique to study the brain in vivo. However, the resolution of dMRI is limited by the low signal-to-noise ratio (SNR) of this technique. Various acquisition strategies have been developed to achieve high resolutions, but they require long scan times. Imaging at ultra-high fields (UHF) could further increase the SNR of single-shot dMRI; however, the shorter T2* and the greater field non-uniformities will degrade image quality. In this study, we investigated the trade-off between the SNR and resolution of different k-space trajectories, including echo planar imaging (EPI), partial Fourier EPI, and spiral, over a range of resolutions at 7T. The effective resolution, spatial specificity and sharpening effect were measured from the point spread function (PSF) of the simulated diffusion sequences for a nominal resolution range of 0.6-1.8 mm. In-vivo scans were acquired using the three readout trajectories. Field probes were used to measure dynamic magnetic fields up to the 3rd order of spherical harmonics. Using a static field map and the measured trajectories image artifacts were corrected, leaving T2* effects as the primary source of blurring. The effective resolution was examined in fractional anisotropy (FA) maps. In-vivo scans were acquired to calculate the SNR. EPI trajectories had the highest specificity, effective resolution, and image sharpening effect, but also had substantially lower SNR. Spirals had significantly higher SNR, but lower specificity. Line plots of the in-vivo scans in phase and frequency encode directions showed ~0.2 units difference in FA values between the different trajectories. The difference between the effective and nominal resolution is greater for spirals than for EPI. However, the higher SNR of spiral trajectories at UHFs allows us to achieve higher effective resolutions compared to EPI and PF-EPI trajectories.