Farit Ardiyanto
Research Subjects
Farit Ardiyanto has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
E B Raharjo
Department of Electrical Engineering, Sekolah Tinggi Teknologi Warga Surakarta, Surakarta, Indonesia
1 shared publication- Haikal Haikal
Sekolah Tinggi Teknologi "Warga" Surakarta
1 shared publication - Margono Margono
Mechanical Engineering Department, Sekolah Tinggi Teknologi Warga Surakarta, Surakarta, Indonesia
1 shared publication - Moch Chamim
Mechanical Engineering Sekolah Tinggi Teknologi "Warga" Surakarta
1 shared publication - Moch. Chamim
Sekolah Tinggi Teknologi Warga Surakarta
1 shared publication R Rahmat
Department of Electrical Engineering, Sekolah Tinggi Teknologi Warga Surakarta, Surakarta, Indonesia
1 shared publication
Latest Publications
- Open Access
- 10 November 2024
- Published by Universitas Muhammadiyah Magelang in BIS Energy and Engineering
- Vol. 1, V124016
Design and manufacturing of control circuits for centrifuge device motors
A centrifuge is a tool that functions to separate organelles based on their density. The working principle of a centrifuge uses the principle of rotation or rotation of the tube containing the solution so that it can be separated based on its density. To mix the blood and reagents in the test tube which is placed in the disk hole, rotation is carried out on the disk hole of the test tube using a DC motor. The rotation of the DC motor greatly influences the process of mixing blood and reagents to achieve even mixing results in the blood ready for testing. Regulating motor speed is very important in centrifuge devices. This research designs and makes a control device to regulate the desired speed of a DC motor to move the disk hole of a test tube containing blood to produce evenly mixed blood and reagents. This DC motor control circuit uses a microcontroller circuit that produces control signals to regulate speed to produce optimal DC motor speed. From the results of DC motor load testing with a disk hole filled with 12 test tubes using the PID algorithm by changing the Kp, Ki and Kd parameters for DC motor speed at speeds of 1000 rpm, 2000 rpm, 3000 rpm and 4000 rpm. The best PID parameter setting values with Kp=2 Ki=0.1 and Kd=2 produce steady state times of 15 seconds, 18 seconds, 15 seconds and 18 seconds. Steady State Error 6%, 6%, 4% and 4.5%. The effect of adding the Kd parameter is not significant on changes in steady state time and Steady State Error.
- 10 November 2024
- Published by Universitas Muhammadiyah Magelang in BIS Energy and Engineering
- Vol. 1, V124016
Open AccessDesign and manufacturing of control circuits for centrifuge device motors
A centrifuge is a tool that functions to separate organelles based on their density. The working principle of a centrifuge uses the principle of rotation or rotation of the tube containing the solution so that it can be separated based on its density. To mix the blood and reagents in the test tube which is placed in the disk hole, rotation is carried out on the disk hole of the test tube using a DC motor. The rotation of the DC motor greatly influences the process of mixing blood and reagents to achieve even mixing results in the blood ready for testing. Regulating motor speed is very important in centrifuge devices. This research designs and makes a control device to regulate the desired speed of a DC motor to move the disk hole of a test tube containing blood to produce evenly mixed blood and reagents. This DC motor control circuit uses a microcontroller circuit that produces control signals to regulate speed to produce optimal DC motor speed. From the results of DC motor load testing with a disk hole filled with 12 test tubes using the PID algorithm by changing the Kp, Ki and Kd parameters for DC motor speed at speeds of 1000 rpm, 2000 rpm, 3000 rpm and 4000 rpm. The best PID parameter setting values with Kp=2 Ki=0.1 and Kd=2 produce steady state times of 15 seconds, 18 seconds, 15 seconds and 18 seconds. Steady State Error 6%, 6%, 4% and 4.5%. The effect of adding the Kd parameter is not significant on changes in steady state time and Steady State Error.
- Open Access
- 27 July 2023
- Published by Universitas Muhammadiyah Surakarta in Media Mesin: Majalah Teknik Mesin
- Vol. 24 (2) , 96-101
EFFECT OF STAINLESS STEEL 304 TIG WELDING AMPERE ON STRESS CORROSION CRACKING PHENOMENON
This article discusses the experimental results of stress corrosion cracking grade 304 stainless steel after GTAW welding under environmental corrosion simulation. The corrosion phenomenon that occurs is Stress Corrosion Cracking (SCC). The experimental method is a specimen welded using a current of 55, 60, and 65 Ampere respectively with a gas flow rate of 5 L/min argon shielding gas. The constant tensile loads of 2000 N and 4000 N in the state of the test object immersed for 2 x 24 hours in a solution of HCl + Aquades. Different Ampere and shielding gas flow rate parameters affected the cracks phenomenon. Vickers Hardness and Microstructure were used to evaluate the weld area. The lowest ampere of the weld results in maximum rough cracks from the surface and it's visible on the surface. The increased hardness of the 55 Ampere current specimen indicates a change in structure or phase after welding. The highest ampere produces fine cracks on all surfaces.
- 27 July 2023
- Published by Universitas Muhammadiyah Surakarta in Media Mesin: Majalah Teknik Mesin
- Vol. 24 (2) , 96-101
Open AccessEFFECT OF STAINLESS STEEL 304 TIG WELDING AMPERE ON STRESS CORROSION CRACKING PHENOMENON
This article discusses the experimental results of stress corrosion cracking grade 304 stainless steel after GTAW welding under environmental corrosion simulation. The corrosion phenomenon that occurs is Stress Corrosion Cracking (SCC). The experimental method is a specimen welded using a current of 55, 60, and 65 Ampere respectively with a gas flow rate of 5 L/min argon shielding gas. The constant tensile loads of 2000 N and 4000 N in the state of the test object immersed for 2 x 24 hours in a solution of HCl + Aquades. Different Ampere and shielding gas flow rate parameters affected the cracks phenomenon. Vickers Hardness and Microstructure were used to evaluate the weld area. The lowest ampere of the weld results in maximum rough cracks from the surface and it's visible on the surface. The increased hardness of the 55 Ampere current specimen indicates a change in structure or phase after welding. The highest ampere produces fine cracks on all surfaces.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2706 (1) , 020017
Characteristic stress corrosion cracking of GTAW stainless steel grade 304 in corrosion environment
This paper deals with experimental investigation of stress corrosion cracking of stainless-steel grade 304 after GTAW welded under simulated environment corrosion. Specimens welded in 60 and 65 Ampere used 5 and 10 L/mnt of Argon shielding gas. Constant tensile load test 4000N and immersed specimen were conducted for 24 hours in Hcl+Aquades solution result variety crack characteristics. After testing, an orange-colored layer of corrosion was seen covering the entire surface. This layer causes corrosion resistance for a certain period of time so that the corrosion process stops. The parameter ampere and shielding gas flow rate affected the crack that occurs. The results of the photo of the microstructure show cracks with the model trans granular at surface and intergranular after crack insert to grains boundaries. Vickers Hardness and Microstructure used to evaluate of welding area. The Lowest ampere of welded result maximum rough crack from surface and The Highest ampere result smooth crack on all of surface.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2706 (1) , 020017
Open AccessCharacteristic stress corrosion cracking of GTAW stainless steel grade 304 in corrosion environment
This paper deals with experimental investigation of stress corrosion cracking of stainless-steel grade 304 after GTAW welded under simulated environment corrosion. Specimens welded in 60 and 65 Ampere used 5 and 10 L/mnt of Argon shielding gas. Constant tensile load test 4000N and immersed specimen were conducted for 24 hours in Hcl+Aquades solution result variety crack characteristics. After testing, an orange-colored layer of corrosion was seen covering the entire surface. This layer causes corrosion resistance for a certain period of time so that the corrosion process stops. The parameter ampere and shielding gas flow rate affected the crack that occurs. The results of the photo of the microstructure show cracks with the model trans granular at surface and intergranular after crack insert to grains boundaries. Vickers Hardness and Microstructure used to evaluate of welding area. The Lowest ampere of welded result maximum rough crack from surface and The Highest ampere result smooth crack on all of surface.