Tanzila Afrin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tanzila Afrin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Yongjun Lai
Department of Mechanical and Materials Engineering, Queen’s University, Kingston, ON K7L 3N6, Canada
2 shared publications - Claire Floras
Department of Engineering Physics, Queen’s University, 99 University Avenue Kingston, Kingston, ON K7L 3N6, Canada
1 shared publication - Justin Jacob
Ingenuity Labs
1 shared publication - Michael Greenspan
Queen's University Canada
1 shared publication - Syed Ali Raza Bukhari
Department of Mechanical and Materials Engineering, Queen’s University, Kingston, ON K7L 3N6, Canada
1 shared publication
Latest Publications
- 8 July 2026
- Published by Springer Nature
- p. 222-227
A Deep Learning Framework for Vision-Based Intraocular Pressure Monitoring Using Microfluidic Contact Lenses
- 8 July 2026
- Published by Springer Nature
- p. 222-227
A Deep Learning Framework for Vision-Based Intraocular Pressure Monitoring Using Microfluidic Contact Lenses
- Open Access
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 15
Contact Lens-Based Intraocular Pressure Sensor
The intraocular pressure (IOP) is the principal indicator for diagnosis of glaucoma which is one of the leading causes of blindness. The IOP can vary throughout the day, and traditional methods of measuring it in a clinical setting only provide a fraction of the patient’s IOP pattern. This article presents a cost-effective way for continuous monitoring of IOP by utilizing a soft contact lens with strategically placed holes. The deformation of these holes due to the change in IOP can be used to detect the pressure variations throughout the day. Extensive COMSOL Multiphysics simulations are conducted to optimize the design and to test the viability of this method. The optimized lens design can achieve a large deformation ratio sensitivity of 0.39 per mmHg with an applied pressure range of 10 mmHg to 40 mmHg.
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 15
Open AccessContact Lens-Based Intraocular Pressure Sensor
The intraocular pressure (IOP) is the principal indicator for diagnosis of glaucoma which is one of the leading causes of blindness. The IOP can vary throughout the day, and traditional methods of measuring it in a clinical setting only provide a fraction of the patient’s IOP pattern. This article presents a cost-effective way for continuous monitoring of IOP by utilizing a soft contact lens with strategically placed holes. The deformation of these holes due to the change in IOP can be used to detect the pressure variations throughout the day. Extensive COMSOL Multiphysics simulations are conducted to optimize the design and to test the viability of this method. The optimized lens design can achieve a large deformation ratio sensitivity of 0.39 per mmHg with an applied pressure range of 10 mmHg to 40 mmHg.