Naoyuki Tsunoda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Naoyuki Tsunoda has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Katsuhide Masui
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
2 shared publications - Takashi Asai
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya City, Japan
2 shared publications - Ayaka Ito
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
1 shared publication - Kei Takahashi
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
1 shared publication
Latest Publications
- 3 September 2025
- Published by Springer Nature in Journal of Anesthesia
- Vol. 40 (1) , 152-153
Halogen checker may be useful to cuff leak test
- 3 September 2025
- Published by Springer Nature in Journal of Anesthesia
- Vol. 40 (1) , 152-153
Halogen checker may be useful to cuff leak test
- Open Access
- 17 February 2025
- Published by Springer Nature in JA Clinical Reports
- Vol. 11 (1) , 1-5
Appropriate shape of a stylet for tracheal intubation using the McGrath® MAC videolaryngoscope in neonates: a randomized crossover simulation study
Background: Guidelines on airway management in neonates and infants recommend using a stylet when a videolaryngoscope is used, but it is not clear if the use of a stylet facilitates tracheal intubation and which shape of the stylet is suitable in neonates. Methods: As a preliminary simulation study of a randomized controlled cross-over design, 25 anesthesiologists (3 specialists, 11 senior residents, and 11 junior residents) used a McGrath® MAC videolaryngoscope (Covidien, Medtronic, Tokyo, Japan) blade 1 for tracheal intubation (of a 3.5-mm ID Shiley™ tube with a cuff), with one of four differently shaped stylets (C-shaped, J-shaped, hockey stick-shaped and double C-shaped) or without a stylet in a manikin of a neonate, and compared intubation times. Results: Compared with intubation time without the use of a stylet, intubation time was significantly longer with the use of the J-shaped stylet (P = 0.007; median (95% CI) difference: 2 (1 to 2) s) or with the hockey stick-shaped stylet (P = 0.0002; median (95% CI) difference: 9 (9 to 10) s). In contrast, intubation time was similar between no stylet and the C-shaped stylet (P = 0.90; median (95% CI) difference: 0 (0 to 0) s) or between no stylet and the double C-shaped style (P = 0.60; median (95% CI) difference: 0 (0 to 0) s). Conclusions: In conclusion, while time to tracheal intubation would be similar with and without the use of a stylet, the shape of the stylet would affect intubation time in neonates.
- 17 February 2025
- Published by Springer Nature in JA Clinical Reports
- Vol. 11 (1) , 1-5
Open AccessAppropriate shape of a stylet for tracheal intubation using the McGrath® MAC videolaryngoscope in neonates: a randomized crossover simulation study
Background: Guidelines on airway management in neonates and infants recommend using a stylet when a videolaryngoscope is used, but it is not clear if the use of a stylet facilitates tracheal intubation and which shape of the stylet is suitable in neonates. Methods: As a preliminary simulation study of a randomized controlled cross-over design, 25 anesthesiologists (3 specialists, 11 senior residents, and 11 junior residents) used a McGrath® MAC videolaryngoscope (Covidien, Medtronic, Tokyo, Japan) blade 1 for tracheal intubation (of a 3.5-mm ID Shiley™ tube with a cuff), with one of four differently shaped stylets (C-shaped, J-shaped, hockey stick-shaped and double C-shaped) or without a stylet in a manikin of a neonate, and compared intubation times. Results: Compared with intubation time without the use of a stylet, intubation time was significantly longer with the use of the J-shaped stylet (P = 0.007; median (95% CI) difference: 2 (1 to 2) s) or with the hockey stick-shaped stylet (P = 0.0002; median (95% CI) difference: 9 (9 to 10) s). In contrast, intubation time was similar between no stylet and the C-shaped stylet (P = 0.90; median (95% CI) difference: 0 (0 to 0) s) or between no stylet and the double C-shaped style (P = 0.60; median (95% CI) difference: 0 (0 to 0) s). Conclusions: In conclusion, while time to tracheal intubation would be similar with and without the use of a stylet, the shape of the stylet would affect intubation time in neonates.