Khoirudin Khoirudin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Khoirudin Khoirudin has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Amri Abdulah
Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Jl. Ir. Sutami 36A Kentingan, Surakarta 57126, Indonesia
6 shared publications Sukarman Sukarman
Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Jl. Ir. Sutami 36A Kentingan, Surakarta 57126, Indonesia
5 shared publications- Budi Kristiawan
Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Jl. Ir. Sutami 36A Kentingan, Surakarta 57126, Indonesia
4 shared publications Agus Supriyanto
Buana Perjuangan University Karawang, Indonesia
2 shared publications- Apang Djafar Shieddieque
Sekolah Tinggi Teknologi Wastukancana, Indonesia
2 shared publications - Budi Santoso
Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Jl. Ir. Sutami 36A Kentingan, Surakarta 57126, Indonesia
2 shared publications
Latest Publications
- Open Access
- 20 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (2) , 86-97
Heat Transfer Characteristic of Al2O3 Nanofluid with Naphthenic Transformers Oil as Base Fluid
Power transformers are static electrical devices with the highest costs compared to other components in the power grid system. Damage to these transformers can lead to significant financial losses, emphasizing the need for high efficiency. One method to enhance transformer oil quality is by adding nanoparticles. Al₂O₃ is commonly used in transformer oil research due to its ability to increase thermal conductivity and breakdown voltage. In this study, Al₂O₃ is incorporated at a concentration of 0.01 wt% and testing equipment is designed to replicate power transformer conditions using an ONAN cooling system. The experimental setup in this study comprised a reservoir made of SUS 304 material, with a thickness of 2 mm and internal dimensions of 300 x 200 x 150 mm. In the center of the reservoir, there is a 650-watt cylindrical heater that simulates a transformer winding. Type K thermocouples monitored temperature changes recorded every 2 seconds over 3 hours. The research results indicate that the most significant temperature increase occurred during the first phase for all samples, with the highest rate recorded at 2.75 °C per minute for a 200-watt input power. Heat transfer coefficient increases with the increasing power in both uninhibited naphthenic mineral oil and nano insulating liquid Al₂O₃ 0.01 wt%. The heat transfer coefficient of the nano insulating liquid Al₂O₃ 0.01 wt% tends to be greater than that of the base fluid, and the same trend is observed in the Nusselt number. What differs is that the value of Ra decreases with the addition of Al₂O₃. The decrease in Ra is an indication that conduction becomes more dominant than convection. Therefore, the use of a small concentration of Al₂O₃ is recommended to minimize the impact of the decrease in Ra. Overall, Al₂O₃ has great potential for use as a cooling oil in power transformers at low concentrations, but further research is needed on other factors to ensure its suitability for industrial applications.
- 20 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (2) , 86-97
Open AccessHeat Transfer Characteristic of Al2O3 Nanofluid with Naphthenic Transformers Oil as Base Fluid
Power transformers are static electrical devices with the highest costs compared to other components in the power grid system. Damage to these transformers can lead to significant financial losses, emphasizing the need for high efficiency. One method to enhance transformer oil quality is by adding nanoparticles. Al₂O₃ is commonly used in transformer oil research due to its ability to increase thermal conductivity and breakdown voltage. In this study, Al₂O₃ is incorporated at a concentration of 0.01 wt% and testing equipment is designed to replicate power transformer conditions using an ONAN cooling system. The experimental setup in this study comprised a reservoir made of SUS 304 material, with a thickness of 2 mm and internal dimensions of 300 x 200 x 150 mm. In the center of the reservoir, there is a 650-watt cylindrical heater that simulates a transformer winding. Type K thermocouples monitored temperature changes recorded every 2 seconds over 3 hours. The research results indicate that the most significant temperature increase occurred during the first phase for all samples, with the highest rate recorded at 2.75 °C per minute for a 200-watt input power. Heat transfer coefficient increases with the increasing power in both uninhibited naphthenic mineral oil and nano insulating liquid Al₂O₃ 0.01 wt%. The heat transfer coefficient of the nano insulating liquid Al₂O₃ 0.01 wt% tends to be greater than that of the base fluid, and the same trend is observed in the Nusselt number. What differs is that the value of Ra decreases with the addition of Al₂O₃. The decrease in Ra is an indication that conduction becomes more dominant than convection. Therefore, the use of a small concentration of Al₂O₃ is recommended to minimize the impact of the decrease in Ra. Overall, Al₂O₃ has great potential for use as a cooling oil in power transformers at low concentrations, but further research is needed on other factors to ensure its suitability for industrial applications.
- Open Access
- 20 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (2) , 177-187
Enhancing Thermal Conductivity of TiO2-3%F+/MEG-40 Binary Nanofluid for Sustainable Cooling Systems in Plastic Injection Molding Applications
This study explores thermal conductivity enhancement in nanofluids for high-temperature applications (70–120°C), specifically targeting plastic injection molding. The research investigates two formulations: TiO2-3%/MEG-40 nanofluid, containing 3 vol% TiO2 nanoparticles, and TiO2-3%F8/MEG-40 binary nanofluid, comprising TiO2 rutile and SiO2 beta-quartz composite nanoparticles in a 92:8 ratio with a total volume fraction of 3 vol%. Both nanofluids were synthesized using the two-step method, with grain size confirmed via scanning and transmission electron microscopy. Thermal conductivity was measured using a TEMPOS Thermal Property Analyzer in a highly insulated heating chamber. Results demonstrated significant enhancements in comparison to the base fluid, with TiO2-3%/MEG-40 nanofluid and TiO2-3%F8/MEG-40 binary nanofluid exhibiting an 18% and 22% increase in thermal conductivity at approximately 95°C. Including SiO2 beta-quartz nanoparticles enhanced dispersion, and thermal conductivity, highlighting their critical role in optimizing performance. These findings demonstrate the potential of TiO2 rutile and SiO2 beta-quartz nanofluids to improve thermal management in industrial processes, advancing beyond existing literature by integrating nanoparticle stability with higher temperature thermal performance.
- 20 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (2) , 177-187
Open AccessEnhancing Thermal Conductivity of TiO2-3%F+/MEG-40 Binary Nanofluid for Sustainable Cooling Systems in Plastic Injection Molding Applications
This study explores thermal conductivity enhancement in nanofluids for high-temperature applications (70–120°C), specifically targeting plastic injection molding. The research investigates two formulations: TiO2-3%/MEG-40 nanofluid, containing 3 vol% TiO2 nanoparticles, and TiO2-3%F8/MEG-40 binary nanofluid, comprising TiO2 rutile and SiO2 beta-quartz composite nanoparticles in a 92:8 ratio with a total volume fraction of 3 vol%. Both nanofluids were synthesized using the two-step method, with grain size confirmed via scanning and transmission electron microscopy. Thermal conductivity was measured using a TEMPOS Thermal Property Analyzer in a highly insulated heating chamber. Results demonstrated significant enhancements in comparison to the base fluid, with TiO2-3%/MEG-40 nanofluid and TiO2-3%F8/MEG-40 binary nanofluid exhibiting an 18% and 22% increase in thermal conductivity at approximately 95°C. Including SiO2 beta-quartz nanoparticles enhanced dispersion, and thermal conductivity, highlighting their critical role in optimizing performance. These findings demonstrate the potential of TiO2 rutile and SiO2 beta-quartz nanofluids to improve thermal management in industrial processes, advancing beyond existing literature by integrating nanoparticle stability with higher temperature thermal performance.
- Open Access
- 10 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (1) , 108-122
Enhancement of Heat Transfer on a Mini Channel Cold Plate by Utilizing Nanofluids Across Various Reynolds Number Variants
This study aims to analyze the thermohydraulic performance of an aluminum mini-channel cold plate (MCCP) using Al₂O₃+EG/W nanofluids at various Reynolds numbers. The investigation focuses on the impact of Reynolds numbers, ranging from 953 to 1588 in laminar flow, on heat transfer enhancement and surface temperature reduction. The results clearly correlate higher Reynolds numbers and lower surface temperatures. The greatest wall temperature reduction of 12.53% was achieved using nanofluid at a Reynolds number of 1588. Heat transfer rates also increased with Reynolds numbers, from 45.93 W at Re = 953 to 67.60 W at Re = 1588. Furthermore, the pressure drop rose with increasing Reynolds numbers, recorded at 33 kPa, 40 kPa, and 51 kPa for Reynolds numbers 953, 1270, and 1588, respectively. The MCCP design in this study was specifically adapted for an electric vehicle battery with a capacity of 3.2 V and 80 Ah (dimensions: 200 mm x 130 mm), making these findings particularly relevant for battery cooling systems, especially in laminar flow applications using nanofluids.
- 10 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (1) , 108-122
Open AccessEnhancement of Heat Transfer on a Mini Channel Cold Plate by Utilizing Nanofluids Across Various Reynolds Number Variants
This study aims to analyze the thermohydraulic performance of an aluminum mini-channel cold plate (MCCP) using Al₂O₃+EG/W nanofluids at various Reynolds numbers. The investigation focuses on the impact of Reynolds numbers, ranging from 953 to 1588 in laminar flow, on heat transfer enhancement and surface temperature reduction. The results clearly correlate higher Reynolds numbers and lower surface temperatures. The greatest wall temperature reduction of 12.53% was achieved using nanofluid at a Reynolds number of 1588. Heat transfer rates also increased with Reynolds numbers, from 45.93 W at Re = 953 to 67.60 W at Re = 1588. Furthermore, the pressure drop rose with increasing Reynolds numbers, recorded at 33 kPa, 40 kPa, and 51 kPa for Reynolds numbers 953, 1270, and 1588, respectively. The MCCP design in this study was specifically adapted for an electric vehicle battery with a capacity of 3.2 V and 80 Ah (dimensions: 200 mm x 130 mm), making these findings particularly relevant for battery cooling systems, especially in laminar flow applications using nanofluids.
- Open Access
- 12 January 2025
- Published by Universitas Muhammadiyah Magelang in Mechanical Engineering for Society and Industry
- Vol. 5 (1) , 133-144
Development of hybrid nanofluids and solar heat exchangers (SHX) to improve heat transfer performance in solar panel cooling
This study examined the thermohydraulic efficiency of a novel Solar Heat Exchanger (SHX) designed for cooling solar panels. The SHX was specifically created for 20 Wp solar panels measuring 450 × 350 mm. The cooling medium was a hybrid nanofluid (HNF) consisting of Alâ‚‚O₃ and SiOâ‚‚ nanoparticles (0.5”“1%) suspended in a base fluid of ethylene glycol and water (EG/W) at a 10:90 ratio. Experiments were performed using flow rates ranging from 1 to 3 LPM. The HNF coolant demonstrated enhanced performance in the solar heat exchanger, with a maximum heat transfer rate increase of 56.07% compared with that of the base fluid. This improvement in the heat-transfer rate was associated with an increase in the heat-transfer coefficient, which was influenced by the flow rate and volume fraction of the HNF. The effectiveness of the HNF surpassed that of the base fluids by approximately 117%. The results indicated that higher flow rates and volume fractions improved cooling performance. The enhanced cooling efficiency and innovative SHX design make this study particularly relevant to the development of solar panel cooling systems, particularly those employing hybrid nanofluid coolants.
- 12 January 2025
- Published by Universitas Muhammadiyah Magelang in Mechanical Engineering for Society and Industry
- Vol. 5 (1) , 133-144
Open AccessDevelopment of hybrid nanofluids and solar heat exchangers (SHX) to improve heat transfer performance in solar panel cooling
This study examined the thermohydraulic efficiency of a novel Solar Heat Exchanger (SHX) designed for cooling solar panels. The SHX was specifically created for 20 Wp solar panels measuring 450 × 350 mm. The cooling medium was a hybrid nanofluid (HNF) consisting of Alâ‚‚O₃ and SiOâ‚‚ nanoparticles (0.5”“1%) suspended in a base fluid of ethylene glycol and water (EG/W) at a 10:90 ratio. Experiments were performed using flow rates ranging from 1 to 3 LPM. The HNF coolant demonstrated enhanced performance in the solar heat exchanger, with a maximum heat transfer rate increase of 56.07% compared with that of the base fluid. This improvement in the heat-transfer rate was associated with an increase in the heat-transfer coefficient, which was influenced by the flow rate and volume fraction of the HNF. The effectiveness of the HNF surpassed that of the base fluids by approximately 117%. The results indicated that higher flow rates and volume fractions improved cooling performance. The enhanced cooling efficiency and innovative SHX design make this study particularly relevant to the development of solar panel cooling systems, particularly those employing hybrid nanofluid coolants.
- Open Access
- 31 October 2024
- Published by LPPMPK - Sekolah Tinggi Teknologi Muhammadiyah Cileungsi in JTTM : Jurnal Terapan Teknik Mesin
- Vol. 5 (2) , 198-207
Analysis of heat transfer coefficient in radiator cooling system using TiO2/CuO hybrid fluid
The automotive industry is growing, encouraging more efficient car cooling systems, especially radiators. Innovations are constantly being made to improve the performance of radiators. Choosing the correct fluid is one of the ways to increase heat transfer. This study aimed to compare the performance of coolant OBC and TiO2/CuO hybrid fluid mixed with coolant OBC to investigate the increase in heat transfer in the car's radiator. The first step is to make TiO2/CuO hybrid fluid with a two-step method, with volume fraction variations of 1.0, 2.0, 3.0, 4.0, and 5.0%, and observe stability for 30 days. Viscosity and thermal conductivity tests are used to assess the thermophysical properties of the sample. Hybrid fluid samples of TiO2 / CuO with a volume fraction of 5.0% showed the best stability and thermal conductivity, then were added to the coolant brand OBC (1:4). The results showed an increase in heat transfer rate of 23% and a heat transfer coefficient of 20% in the TiO2/CuO hybrid fluid added to the coolant OBC
- 31 October 2024
- Published by LPPMPK - Sekolah Tinggi Teknologi Muhammadiyah Cileungsi in JTTM : Jurnal Terapan Teknik Mesin
- Vol. 5 (2) , 198-207
Open AccessAnalysis of heat transfer coefficient in radiator cooling system using TiO2/CuO hybrid fluid
The automotive industry is growing, encouraging more efficient car cooling systems, especially radiators. Innovations are constantly being made to improve the performance of radiators. Choosing the correct fluid is one of the ways to increase heat transfer. This study aimed to compare the performance of coolant OBC and TiO2/CuO hybrid fluid mixed with coolant OBC to investigate the increase in heat transfer in the car's radiator. The first step is to make TiO2/CuO hybrid fluid with a two-step method, with volume fraction variations of 1.0, 2.0, 3.0, 4.0, and 5.0%, and observe stability for 30 days. Viscosity and thermal conductivity tests are used to assess the thermophysical properties of the sample. Hybrid fluid samples of TiO2 / CuO with a volume fraction of 5.0% showed the best stability and thermal conductivity, then were added to the coolant brand OBC (1:4). The results showed an increase in heat transfer rate of 23% and a heat transfer coefficient of 20% in the TiO2/CuO hybrid fluid added to the coolant OBC
- Open Access
- 30 September 2024
- Published by Institut Teknologi Nasional, Bandung in Jurnal Rekayasa Energi dan Mekanika
- Vol. 4 (1) , 36
Optimasi Uji Tegangan Tarik Pengelasan Tungsten Inert Gas pada Penggabungan Beda Material Baja Galvanish (SGCC) dengan Baja Karbon Rendah (SPCC-SD)
Pengelasan adalah salah satu proses utama dalam industri manufaktur yang digunakan untuk menggabungkan dua atau lebih material logam. Salah satu metode pengelasan yang umum digunakan adalah Tungsten Inert Gas (TIG) welding. TIG welding merupakan teknik pengelasan dimana terjadi pembentukan busur listrik antara elektroda yang tidak meleleh dengan material kerja. Pengelasan TIG antara baja galvanis (SGCC) dan baja karbon rendah (SPCC-SD) sering digunakan pada industri otomotif karena kedua material tersebut memiliki karakteristik yang berbeda sehingga bisa digunakan pada kondisi operasional yang berbeda. Penelitian ini menggunakan metode Taguchi dengan tiga tingkat percobaan dan tiga faktor yang berbeda, yaitu Arus listrik, Laju aliran gas argon, dan diameter kampuh las. Hasil penelitian menunjukan bahwa flowrate adalah parameter yang paling penting karena memiliki perbedaan nilai S/N ratio yang paling besar. Hal ini menunjukan flowrate memiliki nilai yang signifikan lebih tinggi daripada arus dan diameter kampuh las sehingga berperan penting dalam menentukan kualitas kekuatan sambungan pengelasan TIG pada material SGCC dan SPCC-SD terhadap tegangan tariknya. Hasil analisis rasio S/N menunjukkan bahwa parameter yang paling optimal adalah arus listrik 55 A, laju aliran gas 18 lpm, dan diameter las 5 mm. Sementara itu, analisis ANOVA menunjukkan bahwa laju aliran gas memiliki kontribusi paling signifikan dalam mempengaruhi beban tarik pada pengelasan TIG bahan SPCC-SD (JIS 3141) dengan SGCC (JIS 3302) yaitu sebesar 23,24%. Selanjutnya disusul oleh diameter kampuh las dan arus pengelasan masing-masing memberikan kontribusi sebesar 19,82% dan 8,34%.
- 30 September 2024
- Published by Institut Teknologi Nasional, Bandung in Jurnal Rekayasa Energi dan Mekanika
- Vol. 4 (1) , 36
Open AccessOptimasi Uji Tegangan Tarik Pengelasan Tungsten Inert Gas pada Penggabungan Beda Material Baja Galvanish (SGCC) dengan Baja Karbon Rendah (SPCC-SD)
Pengelasan adalah salah satu proses utama dalam industri manufaktur yang digunakan untuk menggabungkan dua atau lebih material logam. Salah satu metode pengelasan yang umum digunakan adalah Tungsten Inert Gas (TIG) welding. TIG welding merupakan teknik pengelasan dimana terjadi pembentukan busur listrik antara elektroda yang tidak meleleh dengan material kerja. Pengelasan TIG antara baja galvanis (SGCC) dan baja karbon rendah (SPCC-SD) sering digunakan pada industri otomotif karena kedua material tersebut memiliki karakteristik yang berbeda sehingga bisa digunakan pada kondisi operasional yang berbeda. Penelitian ini menggunakan metode Taguchi dengan tiga tingkat percobaan dan tiga faktor yang berbeda, yaitu Arus listrik, Laju aliran gas argon, dan diameter kampuh las. Hasil penelitian menunjukan bahwa flowrate adalah parameter yang paling penting karena memiliki perbedaan nilai S/N ratio yang paling besar. Hal ini menunjukan flowrate memiliki nilai yang signifikan lebih tinggi daripada arus dan diameter kampuh las sehingga berperan penting dalam menentukan kualitas kekuatan sambungan pengelasan TIG pada material SGCC dan SPCC-SD terhadap tegangan tariknya. Hasil analisis rasio S/N menunjukkan bahwa parameter yang paling optimal adalah arus listrik 55 A, laju aliran gas 18 lpm, dan diameter las 5 mm. Sementara itu, analisis ANOVA menunjukkan bahwa laju aliran gas memiliki kontribusi paling signifikan dalam mempengaruhi beban tarik pada pengelasan TIG bahan SPCC-SD (JIS 3141) dengan SGCC (JIS 3302) yaitu sebesar 23,24%. Selanjutnya disusul oleh diameter kampuh las dan arus pengelasan masing-masing memberikan kontribusi sebesar 19,82% dan 8,34%.
- Open Access
- 3 September 2024
- Published by Politeknik Negeri Lhokseumawe in Jurnal POLIMESIN
- Vol. 22 (4) , 378-382
Optimization of TIG welding parameters for tensile load testing on dissimilar material joints of galvanized steel (SGCC) and low carbon steel (SPCC-SD)
Tungsten Inert Gas (TIG) welding uses a tungsten electrode and argon or helium gas for shielding. It offers excellent shielding, stable arc, adjustable heat input, minimal spattering, and attractive welds. Widely used in various industries, especially for thin materials like galvanized sheets, TIG welding can be challenging for dissimilar materials like galvanized steel and low-carbon steel due to their different melting points. Studying optimal welding parameters is crucial for success. This research focuses on TIG welding of SPCC-SD (JIS 3141) and SGCC (JIS 3302) materials with thicknesses of 0.6 mm and 0.8 mm. The electric current was varied at 45, 50, and 55 A, whereas the gas flow rate was varied at 12, 15, and 18 LPM. The weld bead diameter was varied as 5, 8, and 10 mm. Subsequently, the welded samples were subjected to tensile testing using a SHIMADZU AGS-X 10Kn STD E200V tensile testing machine. The data from the tensile tests were analysed using S/N ratio analysis and Analysis of Variance (ANOVA) with the assistance of the Minitab software. The results of the S/N ratio analysis indicated that the most optimal parameters were an electric current of 55 A, flow rate of 15 LPM, and weld bead diameter of 10 mm. Conversely, the ANOVA revealed that the weld bead diameter significantly influenced the tensile load in TIG welding of SPCC-SD (JIS 3141) with SGCC (JIS 3302) materials, accounting for up to 44.42% of the variation. Following the weld bead diameter, the flow rate and welding current contributed to 21.93% and 16.41%, respectively.
- 3 September 2024
- Published by Politeknik Negeri Lhokseumawe in Jurnal POLIMESIN
- Vol. 22 (4) , 378-382
Open AccessOptimization of TIG welding parameters for tensile load testing on dissimilar material joints of galvanized steel (SGCC) and low carbon steel (SPCC-SD)
Tungsten Inert Gas (TIG) welding uses a tungsten electrode and argon or helium gas for shielding. It offers excellent shielding, stable arc, adjustable heat input, minimal spattering, and attractive welds. Widely used in various industries, especially for thin materials like galvanized sheets, TIG welding can be challenging for dissimilar materials like galvanized steel and low-carbon steel due to their different melting points. Studying optimal welding parameters is crucial for success. This research focuses on TIG welding of SPCC-SD (JIS 3141) and SGCC (JIS 3302) materials with thicknesses of 0.6 mm and 0.8 mm. The electric current was varied at 45, 50, and 55 A, whereas the gas flow rate was varied at 12, 15, and 18 LPM. The weld bead diameter was varied as 5, 8, and 10 mm. Subsequently, the welded samples were subjected to tensile testing using a SHIMADZU AGS-X 10Kn STD E200V tensile testing machine. The data from the tensile tests were analysed using S/N ratio analysis and Analysis of Variance (ANOVA) with the assistance of the Minitab software. The results of the S/N ratio analysis indicated that the most optimal parameters were an electric current of 55 A, flow rate of 15 LPM, and weld bead diameter of 10 mm. Conversely, the ANOVA revealed that the weld bead diameter significantly influenced the tensile load in TIG welding of SPCC-SD (JIS 3141) with SGCC (JIS 3302) materials, accounting for up to 44.42% of the variation. Following the weld bead diameter, the flow rate and welding current contributed to 21.93% and 16.41%, respectively.
- Open Access
Flash Point Improvement of Mineral Oil Utilizing Nanoparticles to Reduce Fire Risk in Power Transformers: A Review
Transformers are crucial equipment in electrical distribution systems but have a significant potential for failure. Insulation materials, including transformer oil (TO), play a primary role in transformer failures. A fire involving the TO can lead to a large explosion, causing the main tank to rupture and resulting in extensive damage to the entire transformer and the surrounding area. Mineral oil (MO) is the most widely used type due to its availability and relatively low cost compared to other types of oil. However, MO has a critical disadvantage, which is its very low flash point. The low flash point makes MO highly flammable. When the oil fires in an enclosed space, such as a transformer tank, the pressure inside the tank increases, leading to a large explosion. Therefore, research on increasing the flash point of MO is highly necessary. The application of nanotechnology is a promising approach to increasing the flash point of base fluids. Research on the effect of nanoparticles (NPs) on flash points is very limited in the literature; thus, there is significant potential for further research in this field. The majority of studies indicate an increase in flash points with the addition of NPs to MO. There is only one study that shows a decrease in flash point, which is −1.33% compared to MO. From all the reviewed studies, it can be concluded that NPs are a potential solution to increase the flash point of MO. Despite their benefits, NPs require a thorough examination of health and environmental impacts, along with proper waste management, to ensure their advantages.
Open AccessFlash Point Improvement of Mineral Oil Utilizing Nanoparticles to Reduce Fire Risk in Power Transformers: A Review
Transformers are crucial equipment in electrical distribution systems but have a significant potential for failure. Insulation materials, including transformer oil (TO), play a primary role in transformer failures. A fire involving the TO can lead to a large explosion, causing the main tank to rupture and resulting in extensive damage to the entire transformer and the surrounding area. Mineral oil (MO) is the most widely used type due to its availability and relatively low cost compared to other types of oil. However, MO has a critical disadvantage, which is its very low flash point. The low flash point makes MO highly flammable. When the oil fires in an enclosed space, such as a transformer tank, the pressure inside the tank increases, leading to a large explosion. Therefore, research on increasing the flash point of MO is highly necessary. The application of nanotechnology is a promising approach to increasing the flash point of base fluids. Research on the effect of nanoparticles (NPs) on flash points is very limited in the literature; thus, there is significant potential for further research in this field. The majority of studies indicate an increase in flash points with the addition of NPs to MO. There is only one study that shows a decrease in flash point, which is −1.33% compared to MO. From all the reviewed studies, it can be concluded that NPs are a potential solution to increase the flash point of MO. Despite their benefits, NPs require a thorough examination of health and environmental impacts, along with proper waste management, to ensure their advantages.
- Open Access
- 7 June 2024
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in ROTASI
- Vol. 26 (3)
Experimental Study of Natural Convection Heat Transfer on A Vertical Cylinder with Varying Heat Flux
The most commonly used heat transfer in cooling and heating systems is convective heat transfer. Natural convection heat transfer is typically employed in cooling systems with immersion cooling such as in data centers and transformers. In addition to cooling systems, natural convection is also utilized in heating systems as seen in nuclear reactors. More specifically, natural convection around heated cylinders has widespread applications. The flow of natural convection around vertical heated cylinders is a critical concern in various applications, including vertical tubes within HVAC systems, the heating of electronic components, and the storage of nuclear rods in waste facilities. In this study, a test apparatus in the form of a box measuring 300x200x150 mm with a 650-watt heater installed in the center was used. The heater is jacketed with an outer diameter of 38mm and a length of 195mm. Thermocouple type K are installed on the heater jacket wall and fluid. Convective heat transfer is transiently calculated with constant heat flux. The research results show that in the first phase, there is a significant increase in heat flux of 512.82 W/m2, 769.23 W/m2, and 1025.4 W/m2, respectively, at rates of 0.34, 0.46, and 0.61 ℃/minute. In phase 4, the temperature increase is relatively small, with rates of 0.01, 0.02, and 0.03 ℃/minute, respectively. Heat transfer coefficients (h), Nusselt numbers (Nu), and Rayleigh numbers (Ra) increase with increasing heat flux.
- 7 June 2024
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in ROTASI
- Vol. 26 (3)
Open AccessExperimental Study of Natural Convection Heat Transfer on A Vertical Cylinder with Varying Heat Flux
The most commonly used heat transfer in cooling and heating systems is convective heat transfer. Natural convection heat transfer is typically employed in cooling systems with immersion cooling such as in data centers and transformers. In addition to cooling systems, natural convection is also utilized in heating systems as seen in nuclear reactors. More specifically, natural convection around heated cylinders has widespread applications. The flow of natural convection around vertical heated cylinders is a critical concern in various applications, including vertical tubes within HVAC systems, the heating of electronic components, and the storage of nuclear rods in waste facilities. In this study, a test apparatus in the form of a box measuring 300x200x150 mm with a 650-watt heater installed in the center was used. The heater is jacketed with an outer diameter of 38mm and a length of 195mm. Thermocouple type K are installed on the heater jacket wall and fluid. Convective heat transfer is transiently calculated with constant heat flux. The research results show that in the first phase, there is a significant increase in heat flux of 512.82 W/m2, 769.23 W/m2, and 1025.4 W/m2, respectively, at rates of 0.34, 0.46, and 0.61 ℃/minute. In phase 4, the temperature increase is relatively small, with rates of 0.01, 0.02, and 0.03 ℃/minute, respectively. Heat transfer coefficients (h), Nusselt numbers (Nu), and Rayleigh numbers (Ra) increase with increasing heat flux.