Wenjing Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenjing Fang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhou
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
12 shared publications - Yijun Zhang
School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou, China
9 shared publications - Siyuan Jiang
School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo, China
6 shared publications - Jiadan Wei
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
5 shared publications - Xiaodong Yu
School of Electrical Engineering, Xuchang University, Xuchang, China
5 shared publications - Lei Xiong
Hefei University
3 shared publications
Latest Publications
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6744-6756
A Two-Step Online Diagnosis Strategy for Open-Phase Fault in Doubly Salient Electromagnetic Motor Drives
Open-phase fault is a common fault in motor drives and occurs as the phase winding is disconnected or one leg of the converter bridge fails, which may generate significant torque ripple and reduce the output torque of the motor. To enhance the reliability of the system, this article proposes a two-step online diagnosis strategy for open-phase faults in doubly salient electromagnetic motor (DSEM) drives. In the first step, the occurrence of open-phase fault is detected based on the variation of active phase currents under normal and fault conditions. In the second step, the differentiation of two fault types (phase-winding open-circuit faults and two-switch open-circuit faults in the same bridge leg) as well as the localization of the fault phase winding can be realized by analyzing the variation of the zero-sequence voltage component (ZSVC) in the fault sector. And combined with the two-phase energization characteristic of the DSEM, the fault bridge leg can be localized based on the changes of the working phase currents within the fault sector and its subsequent sector. Finally, the effectiveness of the proposed method is experimentally verified on a 12/8-pole DSEM system.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6744-6756
A Two-Step Online Diagnosis Strategy for Open-Phase Fault in Doubly Salient Electromagnetic Motor Drives
Open-phase fault is a common fault in motor drives and occurs as the phase winding is disconnected or one leg of the converter bridge fails, which may generate significant torque ripple and reduce the output torque of the motor. To enhance the reliability of the system, this article proposes a two-step online diagnosis strategy for open-phase faults in doubly salient electromagnetic motor (DSEM) drives. In the first step, the occurrence of open-phase fault is detected based on the variation of active phase currents under normal and fault conditions. In the second step, the differentiation of two fault types (phase-winding open-circuit faults and two-switch open-circuit faults in the same bridge leg) as well as the localization of the fault phase winding can be realized by analyzing the variation of the zero-sequence voltage component (ZSVC) in the fault sector. And combined with the two-phase energization characteristic of the DSEM, the fault bridge leg can be localized based on the changes of the working phase currents within the fault sector and its subsequent sector. Finally, the effectiveness of the proposed method is experimentally verified on a 12/8-pole DSEM system.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 3745-3757
Diagnosis of Multiple Faults for DSEM Drive System Based on Bus Current of Switches in Upper Bridge Arm and DC Bus Current
Fault diagnosis is critical to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. There are the same fault characteristics for the open circuit (OC) of switch, OC of phase winding and signal-loss fault of current sensor in the DSEM drive system. However, there is no method addressing the diagnosis of the above three faults simultaneously. To solve this problem, this article proposes a multiple fault diagnosis method for DSEM drive system based on bus current of switches in upper bridge arm and dc bus current. First, based on the working principle of DSEM, two current sensors placed on the phase windings are moved to the bus of switches in upper bridge arm and dc bus. Then, fault location is realized by the dc bus current, the bus current of switches in upper bridge arm and the driving signal of switches. Besides, to solve the problem of incorrect current feedback caused by signal-loss fault, a fault tolerance method based on specific chopping mode is proposed to realize correct current feedback. Finally, the experimental results validate the effectiveness of the proposed method.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 3745-3757
Diagnosis of Multiple Faults for DSEM Drive System Based on Bus Current of Switches in Upper Bridge Arm and DC Bus Current
Fault diagnosis is critical to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. There are the same fault characteristics for the open circuit (OC) of switch, OC of phase winding and signal-loss fault of current sensor in the DSEM drive system. However, there is no method addressing the diagnosis of the above three faults simultaneously. To solve this problem, this article proposes a multiple fault diagnosis method for DSEM drive system based on bus current of switches in upper bridge arm and dc bus current. First, based on the working principle of DSEM, two current sensors placed on the phase windings are moved to the bus of switches in upper bridge arm and dc bus. Then, fault location is realized by the dc bus current, the bus current of switches in upper bridge arm and the driving signal of switches. Besides, to solve the problem of incorrect current feedback caused by signal-loss fault, a fault tolerance method based on specific chopping mode is proposed to realize correct current feedback. Finally, the experimental results validate the effectiveness of the proposed method.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
An Inductance Characteristics-Based Position-Sensorless Startup Method for Doubly Salient Electromagnetic Machine
In this article, a high-performance low-speed sensorless startup method is proposed based on the inductance characteristics of doubly salient electromagnetic machine (DSEM). First, by establishing the nonlinear inductance model related to the rotor position, a position estimation method is developed by capturing the mutual inductance information between the armature and field windings from terminal voltages. Then, for the inductance nonlinearity caused by the doubly salient structure of the motor, a compensation method is proposed to eliminate the position estimation error caused by high-order harmonics of inductance during standstill and startup. Moreover, for the initial rotor position estimation, an accurate convergence method is proposed by analyzing the convergence of the initial estimation. For the position estimation during the startup process, the estimation error caused by polarity changes of field current slope is analyzed, and a corresponding compensation strategy is presented. Additionally, the compensation method is investigated for the commutation error. Compared with existing methods, the proposed method avoids the injection of test pulses and considers the effect of inductance nonlinearity, which can improve the startup performance on the basis of enhancing the estimation accuracy of position angle. Finally, the experiments on a 12/8-pole DSEM validate the correctness of the proposed method.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
An Inductance Characteristics-Based Position-Sensorless Startup Method for Doubly Salient Electromagnetic Machine
In this article, a high-performance low-speed sensorless startup method is proposed based on the inductance characteristics of doubly salient electromagnetic machine (DSEM). First, by establishing the nonlinear inductance model related to the rotor position, a position estimation method is developed by capturing the mutual inductance information between the armature and field windings from terminal voltages. Then, for the inductance nonlinearity caused by the doubly salient structure of the motor, a compensation method is proposed to eliminate the position estimation error caused by high-order harmonics of inductance during standstill and startup. Moreover, for the initial rotor position estimation, an accurate convergence method is proposed by analyzing the convergence of the initial estimation. For the position estimation during the startup process, the estimation error caused by polarity changes of field current slope is analyzed, and a corresponding compensation strategy is presented. Additionally, the compensation method is investigated for the commutation error. Compared with existing methods, the proposed method avoids the injection of test pulses and considers the effect of inductance nonlinearity, which can improve the startup performance on the basis of enhancing the estimation accuracy of position angle. Finally, the experiments on a 12/8-pole DSEM validate the correctness of the proposed method.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 5646-5657
Research on Gain Fault Diagnosis of Current Sensor for Doubly Salient Electromagnetic Motor at Standstill
Fault diagnosis of current sensor is the key technology to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. In some occasions, such as initial position estimation of position sensorless, the motor is at standstill. However, there is no method addressing the fault diagnosis of current sensor for DSEM at standstill. To solve this problem, three methods are proposed to realize gain fault diagnosis of current sensor for DSEM at standstill in this article. One method is realized by detecting excitation current during excitation field building, and the other two are realized by detecting phase currents during the injection of specific current pulses. Then, there is a comparison of three fault diagnosis methods. The proposed method does not require the values of motor parameters, and it can be used either as part of an initial debugging or periodic testing of the system, which can also improve the reliability of initial position estimation to avoid startup failure of motor. Finally, the experimental results validate the effectiveness of the proposed method.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 5646-5657
Research on Gain Fault Diagnosis of Current Sensor for Doubly Salient Electromagnetic Motor at Standstill
Fault diagnosis of current sensor is the key technology to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. In some occasions, such as initial position estimation of position sensorless, the motor is at standstill. However, there is no method addressing the fault diagnosis of current sensor for DSEM at standstill. To solve this problem, three methods are proposed to realize gain fault diagnosis of current sensor for DSEM at standstill in this article. One method is realized by detecting excitation current during excitation field building, and the other two are realized by detecting phase currents during the injection of specific current pulses. Then, there is a comparison of three fault diagnosis methods. The proposed method does not require the values of motor parameters, and it can be used either as part of an initial debugging or periodic testing of the system, which can also improve the reliability of initial position estimation to avoid startup failure of motor. Finally, the experimental results validate the effectiveness of the proposed method.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 1357-1367
Midpoint Voltage of Bridge Arm Based Fault Diagnosis Method of Inverter and Phase Winding for DSEM
In the motor drive system, there are the same fault characteristics for the open circuit (OC) fault of phase winding (OCFOPW) and the two OC fault types of power switch (OCFTOPS). However, there is no method addressing the diagnosis of both OCFOPW and OCFTOPS. In order to solve this problem, this article proposes a fault diagnosis method of inverter and phase winding for doubly salient electromagnetic motor (DSEM) based on the midpoint voltage of bridge arm. First, based on unidirectional conduction of diode and the variation characteristics of back electromotive force (EMF), fault diagnosis is realized by constructing a forward voltage on the antiparallel diode. Then, a voltage threshold is set to eliminate misdiagnosis caused by the conduction voltage drop on the device, and the variation rate of excitation current is varied to ensure effective diagnosis in the case that the back EMF is less than voltage threshold. Finally, the experiments on a 12/8-pole DSEM validate the effectiveness of the proposed method.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 1357-1367
Midpoint Voltage of Bridge Arm Based Fault Diagnosis Method of Inverter and Phase Winding for DSEM
In the motor drive system, there are the same fault characteristics for the open circuit (OC) fault of phase winding (OCFOPW) and the two OC fault types of power switch (OCFTOPS). However, there is no method addressing the diagnosis of both OCFOPW and OCFTOPS. In order to solve this problem, this article proposes a fault diagnosis method of inverter and phase winding for doubly salient electromagnetic motor (DSEM) based on the midpoint voltage of bridge arm. First, based on unidirectional conduction of diode and the variation characteristics of back electromotive force (EMF), fault diagnosis is realized by constructing a forward voltage on the antiparallel diode. Then, a voltage threshold is set to eliminate misdiagnosis caused by the conduction voltage drop on the device, and the variation rate of excitation current is varied to ensure effective diagnosis in the case that the back EMF is less than voltage threshold. Finally, the experiments on a 12/8-pole DSEM validate the effectiveness of the proposed method.
- 30 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (5) , 5200-5214
Sensorless Control of Sinusoidal Doubly Salient Electromagnetic Machine Using Synchronous Frequency Vector Resonant-Based Position Observer
Sliding mode observer (SMO) is widely used in medium- and high-speed sensorless control fields. However, existing SMOs suffer from significant position estimation deviation due to the use of a sliding mode function. In addition, an additional filter is required to suppress the harmonics in SMO, which increases the complexity and computational effort of the system. To address these problems, a synchronous frequency vector resonant (SFVR)-based position observer is proposed and applied to a sinusoidal doubly salient electromagnetic machine (SDSEM) drive in this paper. The characteristic analysis for the amplitude- and phase-frequency of the SFVR reveals that the SFVR can replace the sliding mode function and filter used in existing SMOs, eliminating the position estimation deviation caused by the sliding mode function and solving the complexity issue caused by the filter. Moreover, the estimation performance and robustness of the proposed SFVR-based position observer are analyzed, and a comparison of the proposed method with the existing SMO methods is discussed. The proposed method is simple in structure, easy to implement, and improves the performance of both position and speed estimation under different operating conditions. Finally, the validity of the proposed method is verified on a SDSEM experimental platform.
- 30 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (5) , 5200-5214
Sensorless Control of Sinusoidal Doubly Salient Electromagnetic Machine Using Synchronous Frequency Vector Resonant-Based Position Observer
Sliding mode observer (SMO) is widely used in medium- and high-speed sensorless control fields. However, existing SMOs suffer from significant position estimation deviation due to the use of a sliding mode function. In addition, an additional filter is required to suppress the harmonics in SMO, which increases the complexity and computational effort of the system. To address these problems, a synchronous frequency vector resonant (SFVR)-based position observer is proposed and applied to a sinusoidal doubly salient electromagnetic machine (SDSEM) drive in this paper. The characteristic analysis for the amplitude- and phase-frequency of the SFVR reveals that the SFVR can replace the sliding mode function and filter used in existing SMOs, eliminating the position estimation deviation caused by the sliding mode function and solving the complexity issue caused by the filter. Moreover, the estimation performance and robustness of the proposed SFVR-based position observer are analyzed, and a comparison of the proposed method with the existing SMO methods is discussed. The proposed method is simple in structure, easy to implement, and improves the performance of both position and speed estimation under different operating conditions. Finally, the validity of the proposed method is verified on a SDSEM experimental platform.
- 8 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (1) , 106-122
Super-Twisting Terminal Sliding Mode Decoupling Current Control for Sinusoidal Doubly Salient Electromagnetic Machine Drives
The current control is essential to achieve the high performance of the sinusoidal doubly salient electromagnetic machine (SDSEM). However, the current loop suffers from both the coupling effect and system uncertainty disturbances, which deteriorates its control performance. To address this problem, this paper proposes a super-twisting terminal sliding mode decoupling current control (STTSMD) method, which consists of a current decoupling controller and a super-twisting terminal sliding mode controller. The former can completely decouple the d- and q-axis currents on the premise of ignoring the system uncertainty disturbances, having the advantages of simple structure and easy implementation; the latter can effectively eliminate the adverse influence of the system uncertainty disturbances, having the advantages of fast convergence and chattering suppression. The proposed STTSMD method can improve the dynamic and steady-state response as well as the robustness of SDSEM current control. Finally, the effectiveness of the proposed method is verified by simulation and experiment.
- 8 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (1) , 106-122
Super-Twisting Terminal Sliding Mode Decoupling Current Control for Sinusoidal Doubly Salient Electromagnetic Machine Drives
The current control is essential to achieve the high performance of the sinusoidal doubly salient electromagnetic machine (SDSEM). However, the current loop suffers from both the coupling effect and system uncertainty disturbances, which deteriorates its control performance. To address this problem, this paper proposes a super-twisting terminal sliding mode decoupling current control (STTSMD) method, which consists of a current decoupling controller and a super-twisting terminal sliding mode controller. The former can completely decouple the d- and q-axis currents on the premise of ignoring the system uncertainty disturbances, having the advantages of simple structure and easy implementation; the latter can effectively eliminate the adverse influence of the system uncertainty disturbances, having the advantages of fast convergence and chattering suppression. The proposed STTSMD method can improve the dynamic and steady-state response as well as the robustness of SDSEM current control. Finally, the effectiveness of the proposed method is verified by simulation and experiment.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8572-8584
Position Signal and Nonconduction Phase Current Based Fault Diagnosis Method of Position Sensor for Doubly Salient Electromagnetic Motor
Reliable rotor position information is essential for accurate commutation control of motor drive system. Traditionally, hall sensors have been widely used to obtain rotor position information. The fault of position sensor will lead to the confusion of the commutation logic, which will reduce the output torque of the motor and even fail to operate normally. Therefore, fault diagnosis of position sensor is the key technology to improve the reliability of the system. In this article, a fault diagnosis method of position sensor is proposed for doubly salient electromagnetic motor (DSEM) drive system, which only needs the existing position signals, the driving signals of switch, and the nonconduction phase current. Compared with the existing method, the proposed method does not require additional hardware and complex calculation, can realize the fault diagnosis of single, two and three position sensors, and is not influenced by the variation of speed and load. Besides, the time of error commutation for the proposed method is less than 1/3 electrical angle period, which is helpful to switch the fault-tolerant strategy in time and minimize the damage to the system caused by the fault. In order to verify the effectiveness of the proposed method, experiments are carried out on a 12/8 pole DSEM equipped with three hall position sensors. The experimental results under both steady and dynamic conditions show that the proposed method can quickly realize fault location.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8572-8584
Position Signal and Nonconduction Phase Current Based Fault Diagnosis Method of Position Sensor for Doubly Salient Electromagnetic Motor
Reliable rotor position information is essential for accurate commutation control of motor drive system. Traditionally, hall sensors have been widely used to obtain rotor position information. The fault of position sensor will lead to the confusion of the commutation logic, which will reduce the output torque of the motor and even fail to operate normally. Therefore, fault diagnosis of position sensor is the key technology to improve the reliability of the system. In this article, a fault diagnosis method of position sensor is proposed for doubly salient electromagnetic motor (DSEM) drive system, which only needs the existing position signals, the driving signals of switch, and the nonconduction phase current. Compared with the existing method, the proposed method does not require additional hardware and complex calculation, can realize the fault diagnosis of single, two and three position sensors, and is not influenced by the variation of speed and load. Besides, the time of error commutation for the proposed method is less than 1/3 electrical angle period, which is helpful to switch the fault-tolerant strategy in time and minimize the damage to the system caused by the fault. In order to verify the effectiveness of the proposed method, experiments are carried out on a 12/8 pole DSEM equipped with three hall position sensors. The experimental results under both steady and dynamic conditions show that the proposed method can quickly realize fault location.
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (2) , 2234-2248
A Fault Diagnosis and Fault-Tolerant Control Method for Current Sensors in Doubly Salient Electromagnetic Motor Drive Systems
This paper proposes a fault diagnosis and fault-tolerant control method for three fault modes of current sensors in the doubly salient electromagnetic motor (DSEM) drive system, namely signal loss, gain variation, and zero offset. Firstly, the fault features of current sensors under different fault modes are extracted based on the variation characteristics of three-phase currents in different working sectors to locate and distinguish the fault. Then, a fault-tolerant control method for current sensors is developed to reconstruct the fault phase current under the signal-loss fault and compensate the current online under the gain-variation and zero-offset faults, based on the remaining healthy phase currents and estimated fault coefficients. The proposed method only requires information of three-phase currents and the rotor position, instead of an accurate system model, and immunizes the variation of load and field current, having the advantages of simple implementation and superior robustness. Both simulation and experimental results verify the effectiveness of the proposed method.
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (2) , 2234-2248
A Fault Diagnosis and Fault-Tolerant Control Method for Current Sensors in Doubly Salient Electromagnetic Motor Drive Systems
This paper proposes a fault diagnosis and fault-tolerant control method for three fault modes of current sensors in the doubly salient electromagnetic motor (DSEM) drive system, namely signal loss, gain variation, and zero offset. Firstly, the fault features of current sensors under different fault modes are extracted based on the variation characteristics of three-phase currents in different working sectors to locate and distinguish the fault. Then, a fault-tolerant control method for current sensors is developed to reconstruct the fault phase current under the signal-loss fault and compensate the current online under the gain-variation and zero-offset faults, based on the remaining healthy phase currents and estimated fault coefficients. The proposed method only requires information of three-phase currents and the rotor position, instead of an accurate system model, and immunizes the variation of load and field current, having the advantages of simple implementation and superior robustness. Both simulation and experimental results verify the effectiveness of the proposed method.