Marcela Tarosso Réa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcela Tarosso Réa has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Deborah Queiroz Freitas
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
6 shared publications - Débora Costa Ruiz
Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Espírito Santo, Brazil
5 shared publications - Thaísa Pinheiro Silva
Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
4 shared publications - Christiano Oliveira-Santos
Department of Diagnosis and Oral Health, University of Louisville School of Dentistry, Louisville, USA
3 shared publications - Gustavo Machado Santaella
Assistant Professor, Radiology and Imaging Sciences, Department of Diagnosis and Oral Health, University of Louisville, Louisville, KY, USA
3 shared publications - Maria Fernanda Silva Andrade-Bortoletto
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
3 shared publications
Latest Publications
- 30 October 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant
Objective: To compare the diagnostic accuracy of 3 cone beam computed tomography (CBCT) acquisition protocols, 1 low-resolution (LR) and 2 high-resolution (HR) protocols, using a metal artifact reduction tool (MAR) for detecting a second canal in mandibular incisors adjacent to a zirconia implant. Material and methods: Twenty single-rooted mandibular incisors were included, 12 with 1 canal and 8 with 2 canals confirmed by micro-CT. The roots and a zirconia implant were placed into the alveolar sockets of the right and left mandibular central incisors of a dry human mandible, respectively. In total, 240 CBCT scans were obtained using FOV 5 × 5 cm, 90 kVp, with and without an implant, for each root. The variable parameters included the MAR tool, 1 LR-protocol (0.2 mm voxel, 5 mA), and 2 HR-protocols (0.085 mm voxel, 4 and 10 mA). Five calibrated examiners independently evaluated the scans. An ordinal cumulative link mixed model (CLMM) with crossed random intercepts for roots and examiners was used for data analysis (α = 5%). Results: The CLMM revealed a significant main effect for implant presence (P = .049) and canal status (P < .001), but not for protocol (P = .135) or MAR (P = .392). Significant protocol x canal status (P < .001) and implant x canal status (P < .001) interactions were found, whereas MAR interactions were not significant (P > .05). In 2-canal roots, the zirconia implant significantly induced false-negative shifts under HR-4 (P < .0001) and LR (P < .0001) protocols, whereas HR-10 preserved sensitivity (P = .7760). In single-canal roots, implants induced false-positive shifts in HR-10 (P = .0011) and HR-4 (P = .0011). Conclusion: Zirconia implants impair second canal detection via false-negative and false-positive errors. High-resolution CBCT (HR-10) should be prioritized to preserve diagnostic sensitivity, whereas MAR offers no clinical benefit and cannot compensate for reduced resolution or exposure. Advances in knowledge: CBCT diagnostic performance near zirconia implants relies on acquisition protocol rather than MAR activation. High-resolution CBCT (HR-10) mitigates implant-induced false negatives, whereas lower-resolution or lower-milliamperage protocols compromise diagnostic accuracy.
- 30 October 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant
Objective: To compare the diagnostic accuracy of 3 cone beam computed tomography (CBCT) acquisition protocols, 1 low-resolution (LR) and 2 high-resolution (HR) protocols, using a metal artifact reduction tool (MAR) for detecting a second canal in mandibular incisors adjacent to a zirconia implant. Material and methods: Twenty single-rooted mandibular incisors were included, 12 with 1 canal and 8 with 2 canals confirmed by micro-CT. The roots and a zirconia implant were placed into the alveolar sockets of the right and left mandibular central incisors of a dry human mandible, respectively. In total, 240 CBCT scans were obtained using FOV 5 × 5 cm, 90 kVp, with and without an implant, for each root. The variable parameters included the MAR tool, 1 LR-protocol (0.2 mm voxel, 5 mA), and 2 HR-protocols (0.085 mm voxel, 4 and 10 mA). Five calibrated examiners independently evaluated the scans. An ordinal cumulative link mixed model (CLMM) with crossed random intercepts for roots and examiners was used for data analysis (α = 5%). Results: The CLMM revealed a significant main effect for implant presence (P = .049) and canal status (P < .001), but not for protocol (P = .135) or MAR (P = .392). Significant protocol x canal status (P < .001) and implant x canal status (P < .001) interactions were found, whereas MAR interactions were not significant (P > .05). In 2-canal roots, the zirconia implant significantly induced false-negative shifts under HR-4 (P < .0001) and LR (P < .0001) protocols, whereas HR-10 preserved sensitivity (P = .7760). In single-canal roots, implants induced false-positive shifts in HR-10 (P = .0011) and HR-4 (P = .0011). Conclusion: Zirconia implants impair second canal detection via false-negative and false-positive errors. High-resolution CBCT (HR-10) should be prioritized to preserve diagnostic sensitivity, whereas MAR offers no clinical benefit and cannot compensate for reduced resolution or exposure. Advances in knowledge: CBCT diagnostic performance near zirconia implants relies on acquisition protocol rather than MAR activation. High-resolution CBCT (HR-10) mitigates implant-induced false negatives, whereas lower-resolution or lower-milliamperage protocols compromise diagnostic accuracy.
- 18 February 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (5) , 439-449
Detection of misfits at the abutment-crown interface: comparison between stationary intraoral tomosynthesis and periapical radiography acquired with different vertical angulations
Objectives: To compare the diagnostic accuracy of stationary intraoral tomosynthesis (s-IOT) with periapical radiography (PA) for misfit detection at the abutment-crown interface, across different misfit magnitudes and vertical angulations. Methods: Twenty prototype sets of maxillae and mandibles with implants placed in the maxillary central incisor region were used, and ceramic copings were fabricated. Misfits of 50, 100, and 150 μm were simulated by interposing 50-μm-thick polyester strips at the abutment-crown interface. The group without +simulated misfit had no strips. PA and s-IOT images were acquired using 3 different vertical X-ray tube angulations: perpendicular to the implant (0°), positioned inferiorly (−10°), and superiorly (+10°). Five oral radiologists evaluated 480 images using a 5-point scale. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were analysed using repeated measures ANOVA and Tukey’s post-hoc test (α = 5%). Results: No significant differences were observed between PA and s-IOT (P > .05). AUC at 50 µm was significantly lower than 100 µm for all vertical angulations, and than 150 µm for −10° and +10° (P < .05); 100 µm was also lower than 150 µm for +10° (P < .05). +10° showed lower AUC than 0° and −10° at 50 µm, than 0° at 100 µm, and than −10° at 150 µm (P < .05). Sensitivity increased with misfit magnitude; 100 µm and 150 µm were higher than 50 µm for −10° and +10° (P < .05). +10° showed lower sensitivity than 0° at 50 µm and −10° at 150 µm (P < .05). Specificity varied only by vertical angulation; 0° showed the lowest values (P < .05). Conclusion: PA and s-IOT demonstrated comparable performance, +10° exhibited the lowest accuracy, and larger misfits were more easily detected. Advances in knowledge: s-IOT provides additional bucco-lingual information; however, PA demonstrated comparable diagnostic accuracy in detecting misfits at the abutment-crown interface while exposing patients to lower radiation doses. Additionally, when ideal parallelism cannot be achieved, directing the X-ray beam towards the implant apex, rather than the prosthetic crown, may optimize misfit detection.
- 18 February 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (5) , 439-449
Detection of misfits at the abutment-crown interface: comparison between stationary intraoral tomosynthesis and periapical radiography acquired with different vertical angulations
Objectives: To compare the diagnostic accuracy of stationary intraoral tomosynthesis (s-IOT) with periapical radiography (PA) for misfit detection at the abutment-crown interface, across different misfit magnitudes and vertical angulations. Methods: Twenty prototype sets of maxillae and mandibles with implants placed in the maxillary central incisor region were used, and ceramic copings were fabricated. Misfits of 50, 100, and 150 μm were simulated by interposing 50-μm-thick polyester strips at the abutment-crown interface. The group without +simulated misfit had no strips. PA and s-IOT images were acquired using 3 different vertical X-ray tube angulations: perpendicular to the implant (0°), positioned inferiorly (−10°), and superiorly (+10°). Five oral radiologists evaluated 480 images using a 5-point scale. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were analysed using repeated measures ANOVA and Tukey’s post-hoc test (α = 5%). Results: No significant differences were observed between PA and s-IOT (P > .05). AUC at 50 µm was significantly lower than 100 µm for all vertical angulations, and than 150 µm for −10° and +10° (P < .05); 100 µm was also lower than 150 µm for +10° (P < .05). +10° showed lower AUC than 0° and −10° at 50 µm, than 0° at 100 µm, and than −10° at 150 µm (P < .05). Sensitivity increased with misfit magnitude; 100 µm and 150 µm were higher than 50 µm for −10° and +10° (P < .05). +10° showed lower sensitivity than 0° at 50 µm and −10° at 150 µm (P < .05). Specificity varied only by vertical angulation; 0° showed the lowest values (P < .05). Conclusion: PA and s-IOT demonstrated comparable performance, +10° exhibited the lowest accuracy, and larger misfits were more easily detected. Advances in knowledge: s-IOT provides additional bucco-lingual information; however, PA demonstrated comparable diagnostic accuracy in detecting misfits at the abutment-crown interface while exposing patients to lower radiation doses. Additionally, when ideal parallelism cannot be achieved, directing the X-ray beam towards the implant apex, rather than the prosthetic crown, may optimize misfit detection.
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56
Effect of 45° head angulation and a metal artifact reduction algorithm on cone-beam computed tomography image quality around titanium and zirconia implants
Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e35. https://doi.org/10.5624/isd.20260199
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56
Open AccessEffect of 45° head angulation and a metal artifact reduction algorithm on cone-beam computed tomography image quality around titanium and zirconia implants
Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e35. https://doi.org/10.5624/isd.20260199
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 291
Comparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study
Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e29. https://doi.org/10.5624/isd.20260111
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 291
Open AccessComparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study
Andrade-Bortoletto MF, et al. Imaging Sci Dent. 2026 ;56:e29. https://doi.org/10.5624/isd.20260111
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 273
Evaluation of image quality in conventional intraoral radiographs acquired with a stationary intraoral tomosynthesis system
Ruiz DC, et al. Imaging Sci Dent. 2026 ;56:e21. https://doi.org/10.5624/isd.20260080
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (3) , 273
Open AccessEvaluation of image quality in conventional intraoral radiographs acquired with a stationary intraoral tomosynthesis system
Ruiz DC, et al. Imaging Sci Dent. 2026 ;56:e21. https://doi.org/10.5624/isd.20260080
- Open Access
- 5 August 2025
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 52 (11) , 1584-1594
Dimensional Changes After Different Alveolar Ridge Preservation Techniques for Posterior Region: A Randomised Controlled Clinical Trial
Aim: Alveolar ridge preservation (ARP) after tooth extraction aims to maintain ridge dimensions for future implant placement. However, limited evidence is available for posterior sites. We evaluated the dimensional changes in posterior extraction sockets using four approaches: modified free gingival graft (MFGG); MFGG with xenograft (MFGG + XG); guided bone regeneration with titanium membrane and xenograft (TM + XG); and unassisted socket healing (USH).Materials and Methods: Patients requiring posterior tooth extraction were randomly assigned to one of four groups (n = 22/group). Cone‐beam computed tomography (CBCT) was performed immediately after operation and at 6 months to assess vertical and horizontal alveolar ridge changes and implant‐related outcomes.Results: Significant dimensional changes occurred in all groups (p < 0.05). The TM + XG and MFGG + XG groups showed better preservation of vertical ridge dimensions than the USH and MFGG groups (p < 0.05). Horizontal reductions were significant in all groups (p < 0.05). USH presented the highest sinus floor elevation rate (67% of maxillary cases) and the most frequent use of short implants (< 8.5 mm; 71%). Postoperative pain was significantly greater in the MFGG groups compared to the USH group (p < 0.05).Conclusion: Bone grafting with MFGG or a titanium membrane enhanced ridge preservation and reduced the need for additional surgery compared to USH.Trial Registration: ClinicalTrials.gov identifier: NCT06081296
- 5 August 2025
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 52 (11) , 1584-1594
Open AccessDimensional Changes After Different Alveolar Ridge Preservation Techniques for Posterior Region: A Randomised Controlled Clinical Trial
Aim: Alveolar ridge preservation (ARP) after tooth extraction aims to maintain ridge dimensions for future implant placement. However, limited evidence is available for posterior sites. We evaluated the dimensional changes in posterior extraction sockets using four approaches: modified free gingival graft (MFGG); MFGG with xenograft (MFGG + XG); guided bone regeneration with titanium membrane and xenograft (TM + XG); and unassisted socket healing (USH).Materials and Methods: Patients requiring posterior tooth extraction were randomly assigned to one of four groups (n = 22/group). Cone‐beam computed tomography (CBCT) was performed immediately after operation and at 6 months to assess vertical and horizontal alveolar ridge changes and implant‐related outcomes.Results: Significant dimensional changes occurred in all groups (p < 0.05). The TM + XG and MFGG + XG groups showed better preservation of vertical ridge dimensions than the USH and MFGG groups (p < 0.05). Horizontal reductions were significant in all groups (p < 0.05). USH presented the highest sinus floor elevation rate (67% of maxillary cases) and the most frequent use of short implants (< 8.5 mm; 71%). Postoperative pain was significantly greater in the MFGG groups compared to the USH group (p < 0.05).Conclusion: Bone grafting with MFGG or a titanium membrane enhanced ridge preservation and reduced the need for additional surgery compared to USH.Trial Registration: ClinicalTrials.gov identifier: NCT06081296
- 24 June 2025
- Published by Springer Nature in Oral Radiology
- Vol. 42 (1) , 51-59
Comparison of image quality between intraoral radiographic images using wall-mounted and handheld dental X-ray units
To compare the quality of intraoral radiographic images of two types of dental detectors using wall-mounted and handheld dental X-ray units. Six intraoral dental radiographic images of a Dental Digital Quality Assurance radiographic phantom (Dental Imaging Consultants LLC, San Antonio, TX) were acquired with two types of dental receptors: photostimulable phosphor (PSP) receptor (CS 7600 digital system, Carestream Dental, Rochester, New York, United States) under two conditions, filtered and unfiltered; and a complementary metal oxide semiconductor (CMOS) sensor (RGV 6200, Carestream Dental, Rochester, New York, United States) using handheld (Nomad Pro 2; Kavo Kerr, Biberach, Germany) and wall-mounted (Midmark Preva DC Intraoral X-ray, Midmark Corporation, Illinois, United States) dental X-ray units. Spatial and contrast resolutions and percentage of radiographic contrast were evaluated. Then, radiographic images of an acrylic block were obtained under the same conditions and brightness, noise, and uniformity were assessed. Values were compared between the devices and the digital systems with Analysis of Variance (P < 0.05). There were no differences in spatial and contrast resolutions between dental X-ray units and detectors. Handheld dental X-ray units provide significantly higher radiographic contrast (P < 0.001) and lower brightness, noise, and uniformity (P < 0.001) regardless of the digital system used. Compared to a wall-mounted dental X-ray unit, the handheld device provides higher radiographic contrast and lower brightness, noise, and uniformity regardless of the digital system used.
- 24 June 2025
- Published by Springer Nature in Oral Radiology
- Vol. 42 (1) , 51-59
Comparison of image quality between intraoral radiographic images using wall-mounted and handheld dental X-ray units
To compare the quality of intraoral radiographic images of two types of dental detectors using wall-mounted and handheld dental X-ray units. Six intraoral dental radiographic images of a Dental Digital Quality Assurance radiographic phantom (Dental Imaging Consultants LLC, San Antonio, TX) were acquired with two types of dental receptors: photostimulable phosphor (PSP) receptor (CS 7600 digital system, Carestream Dental, Rochester, New York, United States) under two conditions, filtered and unfiltered; and a complementary metal oxide semiconductor (CMOS) sensor (RGV 6200, Carestream Dental, Rochester, New York, United States) using handheld (Nomad Pro 2; Kavo Kerr, Biberach, Germany) and wall-mounted (Midmark Preva DC Intraoral X-ray, Midmark Corporation, Illinois, United States) dental X-ray units. Spatial and contrast resolutions and percentage of radiographic contrast were evaluated. Then, radiographic images of an acrylic block were obtained under the same conditions and brightness, noise, and uniformity were assessed. Values were compared between the devices and the digital systems with Analysis of Variance (P < 0.05). There were no differences in spatial and contrast resolutions between dental X-ray units and detectors. Handheld dental X-ray units provide significantly higher radiographic contrast (P < 0.001) and lower brightness, noise, and uniformity (P < 0.001) regardless of the digital system used. Compared to a wall-mounted dental X-ray unit, the handheld device provides higher radiographic contrast and lower brightness, noise, and uniformity regardless of the digital system used.
- 30 May 2025
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (9) , 1235-1241
Head Angulation in Cone-beam Computed Tomography Acquisition: Effect on the Diagnostic Accuracy of Vertical Root Fracture Detection
- 30 May 2025
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (9) , 1235-1241
Head Angulation in Cone-beam Computed Tomography Acquisition: Effect on the Diagnostic Accuracy of Vertical Root Fracture Detection
- 5 February 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 54 (5) , 396-403
Development and assessment of a prototype of an interproximal image receptor-holding device for use in paediatric dentistry
To develop and test a prototype for interproximal radiography positioning intended for paediatric dentistry and compare the technical quality of image receptor-holding devices (IRHDs) commonly used in clinical practice. Six prototypes, with 3 wedge dimensions (0.5, 1, and 2 mm, respectively) in upper and lower positions on the bitewing surface were compared regarding their capacity to acquire interproximal radiographs without overlapping surfaces with other IRHDs: RinnXCP, Hawe Kerr, and Cone Indicator. Fifteen graduate students obtained images of deciduous molars in a child’s skull and mandible. The chi-square and Fisher’s exact tests were employed to analyse significant differences in the number of repetitions and failures in obtaining correct images. A one-way analysis of variance (ANOVA) assessed the difference between the mean times required for image acquisition according to each IRHD, adopting a significance level of 5%. The effectiveness of the tested devices, evaluated by the number of correct and incorrect acquisitions using Fisher’s exact test, revealed a P-value of .057. The ANOVA demonstrated statistically significant differences in the mean acquisition times (P < .0000). The upper and lower wedge prototypes 2 mm performed better in acquiring only 1 radiograph (76.7%) and took less time to execute the technique (1.17 and 1.12 min, respectively). The prototypes showed comparable performance to alternative IRHDs but provided advantages in time efficiency and radiation exposure.
- 5 February 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 54 (5) , 396-403
Development and assessment of a prototype of an interproximal image receptor-holding device for use in paediatric dentistry
To develop and test a prototype for interproximal radiography positioning intended for paediatric dentistry and compare the technical quality of image receptor-holding devices (IRHDs) commonly used in clinical practice. Six prototypes, with 3 wedge dimensions (0.5, 1, and 2 mm, respectively) in upper and lower positions on the bitewing surface were compared regarding their capacity to acquire interproximal radiographs without overlapping surfaces with other IRHDs: RinnXCP, Hawe Kerr, and Cone Indicator. Fifteen graduate students obtained images of deciduous molars in a child’s skull and mandible. The chi-square and Fisher’s exact tests were employed to analyse significant differences in the number of repetitions and failures in obtaining correct images. A one-way analysis of variance (ANOVA) assessed the difference between the mean times required for image acquisition according to each IRHD, adopting a significance level of 5%. The effectiveness of the tested devices, evaluated by the number of correct and incorrect acquisitions using Fisher’s exact test, revealed a P-value of .057. The ANOVA demonstrated statistically significant differences in the mean acquisition times (P < .0000). The upper and lower wedge prototypes 2 mm performed better in acquiring only 1 radiograph (76.7%) and took less time to execute the technique (1.17 and 1.12 min, respectively). The prototypes showed comparable performance to alternative IRHDs but provided advantages in time efficiency and radiation exposure.