FAFlorian Auerbach

Florian Auerbach

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Florian Auerbach has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Gerd Uwe Auffarth

    International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany

    1 shared publication
  • Hui Fang

    David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany

    1 shared publication
  • Lu Zhang

    David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Im Neuenheimer Feld 400, Heidelberg 69120, Germany

    1 shared publication
  • Patrick Merz

    David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany

    1 shared publication
  • Perfecto Iii Cagampang

    Molino Doctors Hospital, National Road, Bacoor, Cavite, Philippines

    1 shared publication
  • Sonja Schickhardt

    The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany

    1 shared publication

Latest Publications

  • Open Access

    Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study

    by Lu Zhang, Sonja Schickhardt, Hui Fang, Florian Auerbach, Perfecto Iii Cagampang, Patrick R. Merz, Gerd U. Md Febo Auffarth

    Purpose: To compare 1 new intraocular lens injector system against 3 standard injector systems in porcine eyes. Setting: David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany. Design: In vitro laboratory study. Methods: In 70 porcine eyes, +20.0 diopter IOLs were implanted with the following systems: multiSert, UltraSert, iTec and RayOne, i.e., S1.8 (incision size: 1.8mm), S2.0 (2.0mm), S2.2P (2.2mm, push-mode), S2.2S (2.2mm, screw-mode), U2.2 (2.2mm), iT2.2 (2.2mm) and R2.0 (2.0mm). Corneal incision sizes were measured before and after implantation with a incision gauge set. Ease of use was evaluated using a Likert scale. IOL delivery time and performance were determined based on Miyake-Apple view videos. Results: The incision enlargements were 0.36 ± 0.08mm (S1.8), 0.15 ± 0.07mm (S2.0), 0.17 ± 0.12mm (S2.2P), 0.28 ± 0.10mm (S2.2S), 0.32 ± 0.09mm (U2.2), 0.30 ± 0.08mm (iT2.2) and 0.35 ± 0.11mm (R2.0). Total scores of ease of use were 23.00 (S1.8), 25.00 (S2.0), 29.00 (S2.2P), 26.00 (S2.2S), 26.00 (U2.2), 25.00 (iT2.2) and 24.00 (R2.0). As for the mean delivery time, iT2.2 took the longest time (13.20 ± 3.29 seconds), while S2.2S took the shortest time (4.50 ± 0.71 seconds). Haptic-optic adhesion was observed in S1.8 (4, 40%), S2.2P (2, 20%), U2.2 (5, 50%) and iT2.2 (5, 50%). Conclusions: Injector S, with the appropriate incision size and implantation method, could achieve better results regarding incision enlargement, ease of use, delivery time and performance than other injector systems. There was an indirect relationship between incision size and inadvertent events.