DLDaniel Lin

Daniel Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Lin has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A mixed reality hand fracture simulator for virtual K-wire fixation

    by Jimmy Qiu, Trinette Wright, Stephanie Williams, Daniel Lin, Clare McElcheran, Stefan Hofer, Blake Murphy, Joseph Catapano

    Purpose Proper management of hand fractures requires accurate reduction of bone fragments and stabilization with Kirschner wire (K-wire) fixation. Limited case exposure in residency and a shortage of feedback-rich skills assessment constrain deliberate practice. This work describes a mixed reality hand fracture simulator that integrates a realistic physical model with instrument tracking, real-time virtual image guidance, and quantitative performance feedback for training percutaneous K-wire fixation. Methods We developed a benchtop mixed reality (MR) simulator integrating an electromagnetic (EM) tracker, a three-dimensional (3D)-printed hand model with fracture patterns, and a microcontroller-enabled K-wire driver. To ensure high physical-to-virtual geometric correspondence, the 3D-printed components were optically scanned to serve as virtual representations. A custom application provides real-time 3D visualization, guidance, and simulated virtual X-rays. To evaluate system accuracy, five users performed repeated paired-point rigid registrations. Accuracy was assessed by calculating fiducial registration error (FRE) and target registration error (TRE) across 25 attempts using a pre-calibrated stylus and the tracked K-wire driver. Image guidance capabilities were evaluated by measuring positional and angular alignment errors of the tracked K-wire driver against predefined ideal trajectories. Results The overall mean FRE was 0.69 ± 0.11 mm for the hand model (11 fiducials) and 0.60 ± 0.09 mm for the K-wire driver (8 fiducials). Target localization to six ground-truth targets yielded a mean TRE of 0.69 ± 0.10 mm with the stylus and 0.82 ± 0.16 mm with the driver. Trajectory alignment demonstrated maximum positional variance during parallel approaches to the bone (K-wire 1), highlighting specific procedural challenges. Conclusions The MR hand fracture simulator platform enables repeated practice of fracture reduction and K-wire placement with interactive guidance, simulated X-rays, and objective metrics. The system is able to achieve millimeter-scale alignment suitable for procedural training. Future work will evaluate learning outcomes and skill transfer in surgical trainees.