Shi Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shi Lin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Liqun Zhou
College of Petrochemical Engineering Lanzhou University of Technology Lanzhou China
3 shared publications - Kunyu Zhuang
College of Chemical Engineering, Fuzhou University, Fuzhou 350116, China
2 shared publications Liqun Zhou
2 shared publications- Xi Liu
College of Chemical Engineering, Fuzhou University, Fuzhou 350116, China
2 shared publications - Bowen Zhao
College of Petrochemical Engineering Lanzhou University of Technology Lanzhou China
1 shared publication Chaojie Li
1 shared publication
Latest Publications
- 19 February 2026
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 104 (9) , 5121-5132
CFD investigation on thermal–hydraulic performance of flow boiling within micro‐pillar array surfaces
Micro‐structured surfaces are widely applied to enhance surface wettability and reduce hydraulic resistance. The study employs computational fluid dynamics (CFD) theory to investigate the flow boiling heat transfer performance of micro‐pillar array surfaces. A three‐dimensional dual‐channel model with micro‐pillar arrayed surface is developed. The volume of fluid (VOF) model is utilized to capture the two‐phase flow behaviour, and the mass transfer process is calculated by the Lee model. R134a is used as a working fluid undergoing phase transition. The effects of micro‐pillar height, diameter, and degree of subcooling are investigated. Parametric analyses revealed that the performance evaluation criterion (PEC) decreased by 18% and 47.9% with increasing pillar height (1–4 mm) and diameter (1–6 mm), respectively, due to flow stagnation and elevated friction losses. The performance evaluation criterion (PEC) were positively correlated with elevated subcooling levels. The optimal geometry (3 mm height and 1 mm diameter) achieved a 58.6% PEC superiority over traditional herringbone corrugations.
- 19 February 2026
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 104 (9) , 5121-5132
CFD investigation on thermal–hydraulic performance of flow boiling within micro‐pillar array surfaces
Micro‐structured surfaces are widely applied to enhance surface wettability and reduce hydraulic resistance. The study employs computational fluid dynamics (CFD) theory to investigate the flow boiling heat transfer performance of micro‐pillar array surfaces. A three‐dimensional dual‐channel model with micro‐pillar arrayed surface is developed. The volume of fluid (VOF) model is utilized to capture the two‐phase flow behaviour, and the mass transfer process is calculated by the Lee model. R134a is used as a working fluid undergoing phase transition. The effects of micro‐pillar height, diameter, and degree of subcooling are investigated. Parametric analyses revealed that the performance evaluation criterion (PEC) decreased by 18% and 47.9% with increasing pillar height (1–4 mm) and diameter (1–6 mm), respectively, due to flow stagnation and elevated friction losses. The performance evaluation criterion (PEC) were positively correlated with elevated subcooling levels. The optimal geometry (3 mm height and 1 mm diameter) achieved a 58.6% PEC superiority over traditional herringbone corrugations.
- 26 May 2025
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 20 (4)
Performance Assessment and Improvement of Two‐Phase Immersion Cooling for Multi‐Chip Module
Thermal management of chips is a key bottleneck to power densification. Two‐phase immersion methods provide a potential alternative to realize the goal of thermal management on chips. In this paper, a numerical model of a multi‐chip module is established to evaluate the thermal performance of two‐phase immersion cooling based on the CFD method. The effects of coolant type, inlet velocity, and subcooling are investigated. The results indicate that the coolant type, inlet velocity, and subcooling significantly affect the temperature of the multi‐chip module. Compared with FC‐72, the chip temperature dropped considerably by using Novec7100, which has higher latent heat. When the inlet subcooling remains constant, the chip temperature gradually decreases as the coolant flow rate increases. The chip temperature remains virtually stable when the inlet velocity exceeds 0.8 m/s. For this model, the optimal subcooling should be around 30°C. The baffle can effectively improve the overall temperature uniformity of the multi‐chip module. The addition of the baffle can reduce the temperature uniformity coefficient of the chip by up to 63.08%. After further optimization, the temperature uniformity is increased by 35.89%.
- 26 May 2025
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 20 (4)
Performance Assessment and Improvement of Two‐Phase Immersion Cooling for Multi‐Chip Module
Thermal management of chips is a key bottleneck to power densification. Two‐phase immersion methods provide a potential alternative to realize the goal of thermal management on chips. In this paper, a numerical model of a multi‐chip module is established to evaluate the thermal performance of two‐phase immersion cooling based on the CFD method. The effects of coolant type, inlet velocity, and subcooling are investigated. The results indicate that the coolant type, inlet velocity, and subcooling significantly affect the temperature of the multi‐chip module. Compared with FC‐72, the chip temperature dropped considerably by using Novec7100, which has higher latent heat. When the inlet subcooling remains constant, the chip temperature gradually decreases as the coolant flow rate increases. The chip temperature remains virtually stable when the inlet velocity exceeds 0.8 m/s. For this model, the optimal subcooling should be around 30°C. The baffle can effectively improve the overall temperature uniformity of the multi‐chip module. The addition of the baffle can reduce the temperature uniformity coefficient of the chip by up to 63.08%. After further optimization, the temperature uniformity is increased by 35.89%.
- 16 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 244
Research on the performance failure of phase change materials thermal management for lithium battery
- 16 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 244
Research on the performance failure of phase change materials thermal management for lithium battery
- 16 July 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 418
Thermal performance of rectangular serpentine mini-channel cooling system on lithium battery
- 16 July 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 418
Thermal performance of rectangular serpentine mini-channel cooling system on lithium battery
- Open Access
- 26 December 2018
- Published by MDPI AG in Applied Sciences
- Vol. 9 (1) , 74
Performance Study and Efficiency Improvement of Ice Slurry Production by Scraped-Surface Method
In this study, the performance of ice slurry production by scraped-surface method was experimentally investigated. Temperature change characteristics, ice packing fraction (IPF) of ice slurry, power consumption of scraping system and coefficient of performance (COP) were measured by varying the concentration of sodium chloride solution, scraping speed, and solution flow rate. The effect of nanosilica on efficiency of ice slurry production was also studied. The results showed that scraping power consumption accounted for only a small proportion (about 5%) of the total power consumption of the system. An increase in the concentration of sodium chloride caused a decrease in the IPF and a decrease in the COP of the system. With the solution flow rate at 1.3 m3/h and scraping speed at 13 rpm, the maximum COP (2.43) was obtained. Furthermore, the addition of nanosilica had a significant effect on improving the system COP.
- 26 December 2018
- Published by MDPI AG in Applied Sciences
- Vol. 9 (1) , 74
Open AccessPerformance Study and Efficiency Improvement of Ice Slurry Production by Scraped-Surface Method
In this study, the performance of ice slurry production by scraped-surface method was experimentally investigated. Temperature change characteristics, ice packing fraction (IPF) of ice slurry, power consumption of scraping system and coefficient of performance (COP) were measured by varying the concentration of sodium chloride solution, scraping speed, and solution flow rate. The effect of nanosilica on efficiency of ice slurry production was also studied. The results showed that scraping power consumption accounted for only a small proportion (about 5%) of the total power consumption of the system. An increase in the concentration of sodium chloride caused a decrease in the IPF and a decrease in the COP of the system. With the solution flow rate at 1.3 m3/h and scraping speed at 13 rpm, the maximum COP (2.43) was obtained. Furthermore, the addition of nanosilica had a significant effect on improving the system COP.
- Open Access
Determination of Supercooling Degree, Nucleation and Growth Rates, and Particle Size for Ice Slurry Crystallization in Vacuum
Understanding the crystallization behavior of ice slurry under vacuum condition is important to the wide application of the vacuum method. In this study, we first measured the supercooling degree of the initiation of ice slurry formation under different stirring rates, cooling rates and ethylene glycol concentrations. Results indicate that the supercooling crystallization pressure difference increases with increasing cooling rate, while it decreases with increasing ethylene glycol concentration. The stirring rate has little influence on supercooling crystallization pressure difference. Second, the crystallization kinetics of ice crystals was conducted through batch cooling crystallization experiments based on the population balance equation. The equations of nucleation rate and growth rate were established in terms of power law kinetic expressions. Meanwhile, the influences of suspension density, stirring rate and supercooling degree on the process of nucleation and growth were studied. Third, the morphology of ice crystals in ice slurry was obtained using a microscopic observation system. It is found that the effect of stirring rate on ice crystal size is very small and the addition of ethylene glycoleffectively inhibits the growth of ice crystals. The results in this paper can provide theoretical guidance and technical support for the development of vacuum icemakers.
Open AccessDetermination of Supercooling Degree, Nucleation and Growth Rates, and Particle Size for Ice Slurry Crystallization in Vacuum
Understanding the crystallization behavior of ice slurry under vacuum condition is important to the wide application of the vacuum method. In this study, we first measured the supercooling degree of the initiation of ice slurry formation under different stirring rates, cooling rates and ethylene glycol concentrations. Results indicate that the supercooling crystallization pressure difference increases with increasing cooling rate, while it decreases with increasing ethylene glycol concentration. The stirring rate has little influence on supercooling crystallization pressure difference. Second, the crystallization kinetics of ice crystals was conducted through batch cooling crystallization experiments based on the population balance equation. The equations of nucleation rate and growth rate were established in terms of power law kinetic expressions. Meanwhile, the influences of suspension density, stirring rate and supercooling degree on the process of nucleation and growth were studied. Third, the morphology of ice crystals in ice slurry was obtained using a microscopic observation system. It is found that the effect of stirring rate on ice crystal size is very small and the addition of ethylene glycoleffectively inhibits the growth of ice crystals. The results in this paper can provide theoretical guidance and technical support for the development of vacuum icemakers.