Si-Lin Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Si-Lin Chen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Chun-Ying Lin
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medicine Science, Guangzhou, 510100, China
1 shared publicationDong-Li Chen
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medicine Science, Guangzhou, 510100, China
1 shared publicationHong-Wen Fei
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medicine Science, Guangzhou, 510100, China
1 shared publication- Lie Liu
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510000, Guangdong, China.
1 shared publication - Shulin Wu
Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Science, Southern Medical University, Guangzhou, China
1 shared publication - Yuan-Hong Liang
Department of Cardiology, Guangdong General Hospital, Guangdong Cardiovascular Institute, Guangdong Academy of Medical Science, Guangzhou, China
1 shared publication
Latest Publications
- 16 December 2015
- Published by Springer Nature in Current Medical Science
- Vol. 35 (6) , 858-861
Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety
Lead placement for ventricular pacing variably impacts the physiological benefit of the patient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63±21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the septum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projection. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No differences were identified in threshold, impedance or R-wave sensing between the two groups at 1st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period.
- 16 December 2015
- Published by Springer Nature in Current Medical Science
- Vol. 35 (6) , 858-861
Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety
Lead placement for ventricular pacing variably impacts the physiological benefit of the patient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63±21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the septum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projection. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No differences were identified in threshold, impedance or R-wave sensing between the two groups at 1st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period.