Zhaolei He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhaolei He has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Biao Tang
Electric Power Research Institute of Yunnan Power Grid Co., Ltd., Kunming 650200, China
1 shared publication - Fang Zeng
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Hongchun Shu
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Hongda Tang
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Mengmeng Zhu
Electric Power Research Institute of Yunnan Power Grid Co., Ltd., Kunming 650200, China
1 shared publication - Pulin Cao
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication
Latest Publications
- Open Access
Analysis of Controllability in Cyber–Physical Power Systems under a Novel Load-Capacity Model
In cyber–physical power systems (CPPSs), system collapse can occur as a result of a failure in a particular component. In this paper, an approach is presented to build the load-capacity model of CPPSs using the concept of electrical betweenness and information entropy, which takes into account real-time node loads and the allocation of power and information flows within CPPSs. By introducing an innovative load redistribution strategy and comparing it with conventional load distribution strategies, the superior effectiveness of the proposed strategy in minimizing system failures and averting system collapses has been demonstrated. The controllability of the system after cascading failures under different coupling strategies and capacity parameters is investigated through the analysis of different information network topologies and network parameters. It was observed that CPPSs constructed using small-world networks, which couple high-degree nodes from the information network to high-betweenness nodes from the power grid, exhibit improved resilience. Furthermore, increasing the capacity parameter of the power network yields more favorable results compared to increasing the capacity parameter of the information network. In addition, our research results are validated using the IEEE 39-node system and the Chinese 132-node system.
Open AccessAnalysis of Controllability in Cyber–Physical Power Systems under a Novel Load-Capacity Model
In cyber–physical power systems (CPPSs), system collapse can occur as a result of a failure in a particular component. In this paper, an approach is presented to build the load-capacity model of CPPSs using the concept of electrical betweenness and information entropy, which takes into account real-time node loads and the allocation of power and information flows within CPPSs. By introducing an innovative load redistribution strategy and comparing it with conventional load distribution strategies, the superior effectiveness of the proposed strategy in minimizing system failures and averting system collapses has been demonstrated. The controllability of the system after cascading failures under different coupling strategies and capacity parameters is investigated through the analysis of different information network topologies and network parameters. It was observed that CPPSs constructed using small-world networks, which couple high-degree nodes from the information network to high-betweenness nodes from the power grid, exhibit improved resilience. Furthermore, increasing the capacity parameter of the power network yields more favorable results compared to increasing the capacity parameter of the information network. In addition, our research results are validated using the IEEE 39-node system and the Chinese 132-node system.
- Open Access
Field Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.
Open AccessField Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.