Cristiane Barros André
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cristiane Barros André has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Bruno de Paula Machado Pasqua
University of São Paulo, Brazil
3 shared publications - José Rino Neto
Universidade Federal de Goiás, Brazil
3 shared publications - Fábio Dupart Nascimento
Department of Biochemistry, Molecular Biology division, Federal University of São Paulo - UNIFESP/EPM, São Paulo, Brazil
2 shared publications - João Batista de Paiva
Department of Orthodontics, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil
2 shared publications - B. P. M. Pasqua
School of Orthodontics, University of São Paulo, São Paulo, Brazil
1 shared publication - Benedict Wilmes
Department of Orthodontics, University of Düsseldorf, Düsseldorf, Germany
1 shared publication
Latest Publications
- 20 December 2024
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 167 (4) , 436-443
Dentoskeletal effects of miniscrew-anchored maxillary protraction: Evaluating the role of mandibular anchorage bar and night facemask
- 20 December 2024
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 167 (4) , 436-443
Dentoskeletal effects of miniscrew-anchored maxillary protraction: Evaluating the role of mandibular anchorage bar and night facemask
- 5 August 2024
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (1) , 43-54
Periodontal evaluation after maxillary expansion with a tooth–bone-borne expander in growing patients
Purpose This two-arm parallel randomized controlled trial aimed to evaluate and compare periodontal changes due to rapid maxillary expansion (RME) using tooth–bone-borne and tooth-borne devices in growing patients via clinical examinations and cone-beam computed tomography (CBCT). Materials and methods Forty-two eligible patients (aged 11–14 years; transverse maxillary deficiency, posterior crossbite) were screened and divided into two groups based on the treatment received (randomization was performed using computer-generated numeric sequences): hybrid hyrax tooth–bone-borne group (TBB) and hyrax tooth-borne group (TB). The primary outcome was the change in cortical bone thickness (by CBCT). In addition, the clinical attachment level (CAL), gingival recession, and bleeding were assessed. Both examinations were performed before and 3 months after the activation phase. Intergroup comparisons were performed using analysis of covariance (ANCOVA; P < 0.05). Results Twenty-one patients (12 girls and 9 boys; mean initial age, 13.3 years) were included in the TBB group and 21 (5 girls and 16 boys; mean initial age, 13.2 years) were included in the TB group. The TB group exhibited a decrease in buccal bone thickness in the first premolars and first molars at all three evaluated levels. Specifically, tooth 14 at 3 mm from the enamel–cement junction showed a significant width reduction (0.7 mm; p < 0.001), accompanied by a notable increase in palatal cortical thickness at 6 mm of enamel–cement junction (1.13 mm; p < 0.001). Conclusions RME resulted in buccal bone thickness reduction at the first premolar with hyrax treatment. In the molar region, both devices resulted in cortical bone alterations that were less pronounced in the TBB group.
- 5 August 2024
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (1) , 43-54
Periodontal evaluation after maxillary expansion with a tooth–bone-borne expander in growing patients
Purpose This two-arm parallel randomized controlled trial aimed to evaluate and compare periodontal changes due to rapid maxillary expansion (RME) using tooth–bone-borne and tooth-borne devices in growing patients via clinical examinations and cone-beam computed tomography (CBCT). Materials and methods Forty-two eligible patients (aged 11–14 years; transverse maxillary deficiency, posterior crossbite) were screened and divided into two groups based on the treatment received (randomization was performed using computer-generated numeric sequences): hybrid hyrax tooth–bone-borne group (TBB) and hyrax tooth-borne group (TB). The primary outcome was the change in cortical bone thickness (by CBCT). In addition, the clinical attachment level (CAL), gingival recession, and bleeding were assessed. Both examinations were performed before and 3 months after the activation phase. Intergroup comparisons were performed using analysis of covariance (ANCOVA; P < 0.05). Results Twenty-one patients (12 girls and 9 boys; mean initial age, 13.3 years) were included in the TBB group and 21 (5 girls and 16 boys; mean initial age, 13.2 years) were included in the TB group. The TB group exhibited a decrease in buccal bone thickness in the first premolars and first molars at all three evaluated levels. Specifically, tooth 14 at 3 mm from the enamel–cement junction showed a significant width reduction (0.7 mm; p < 0.001), accompanied by a notable increase in palatal cortical thickness at 6 mm of enamel–cement junction (1.13 mm; p < 0.001). Conclusions RME resulted in buccal bone thickness reduction at the first premolar with hyrax treatment. In the molar region, both devices resulted in cortical bone alterations that were less pronounced in the TBB group.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 29 (4) , e242458
MARPE expander activation load with different configurations of extender arms heights: in-vitro evaluation
Objective: Evaluate the load mini-implants exert on the artificial bone when expanding the MARPE EX in three different extension arm configurations. Methods: A device simulating the human palate was fabricated and attached to a universal testing machine, for conducting tests with different MARPE expanders (n=5): non-adjustable/control (MARPE SL, Peclab) or with low, intermediate, and high extender arms (MARPE EX, Peclab). The expanders were manually activated until failure of the device occurred, and maximum load values were recorded. Load averages were also calculated for every five activations until the twentieth activation. Results: The generalized linear mixed model for repeated measures over time showed that there was significant increase in load with activations for all expanders (p=0.0004). Up to the twentieth activation, the expander with low extender arms presented higher load than the others, while the expander with high extender arms showed lower load values (p<0.05). There was no significant difference among expanders regarding the number of activations (p=0.0586), although there was a trend towards fewer activations until fracture for the control expander. It was observed that the higher the configuration, the lower the force the mini-implants delivered to the bone. The control expander provided a force magnitude similar to that of the adjustable expander when positioned at the intermediate height. Conclusions: The activation load of MARPE expanders is influenced by the type of presentation of the extensor arms, with higher configurations resulting in lower force delivered by the mini-implants to the bone.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 29 (4) , e242458
Open AccessMARPE expander activation load with different configurations of extender arms heights: in-vitro evaluation
Objective: Evaluate the load mini-implants exert on the artificial bone when expanding the MARPE EX in three different extension arm configurations. Methods: A device simulating the human palate was fabricated and attached to a universal testing machine, for conducting tests with different MARPE expanders (n=5): non-adjustable/control (MARPE SL, Peclab) or with low, intermediate, and high extender arms (MARPE EX, Peclab). The expanders were manually activated until failure of the device occurred, and maximum load values were recorded. Load averages were also calculated for every five activations until the twentieth activation. Results: The generalized linear mixed model for repeated measures over time showed that there was significant increase in load with activations for all expanders (p=0.0004). Up to the twentieth activation, the expander with low extender arms presented higher load than the others, while the expander with high extender arms showed lower load values (p<0.05). There was no significant difference among expanders regarding the number of activations (p=0.0586), although there was a trend towards fewer activations until fracture for the control expander. It was observed that the higher the configuration, the lower the force the mini-implants delivered to the bone. The control expander provided a force magnitude similar to that of the adjustable expander when positioned at the intermediate height. Conclusions: The activation load of MARPE expanders is influenced by the type of presentation of the extensor arms, with higher configurations resulting in lower force delivered by the mini-implants to the bone.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 29 (3) , e242439
Miniscrew-assisted rapid palatal expansion (MARPE): Factors influencing planning
Objective: This cross-sectional study evaluated the bone thickness on mini-implants insertion site, the factors that influence the digital planning of MARPE appliance (miniscrew-assisted rapid palatal expansion), and its different designs. Methods: A total of 135 plannings were assessed regarding the size of the expander screw used, the positioning and the type of the mini-implant rings, and their location in relation to the teeth. Bone thickness measurements were assessed in the region of the mini-implants’ trajectory. Differences between the sexes was verified using the ANOVA test (5% significance). Results: 73 cases were planned with 4 mini-implants and 62 cases, with 6 mini-implants. In 90% of cases, teeth #16 and #26 were used as supports, and the most used expander screw was 13mm (64.1% of cases). The anterior mini-implants of conventional MARPE showed more pronounced insertion in bone in males (5.9 ± 2mm; p= 0.025). The extra mini-implants (anterior region) were inserted with greater bone thickness in males (11.1 ± 2.3mm) compared to females (9.9 ± 1.8mm; p=0.041). A greater bone thickness was observed in males (10.1 ± 2.1 mm) when using mini-implants in the paramedian region. Conclusion: Additional rings allow more pronounced bone insertion. Male patients had greater bone thickness, which may be related to greater difficulty in opening the sutures. The alveolar process region seems to be a satisfactory site for mini-implants to those patients with reduced bone thickness in the paramedian posterior region. MARPE appliance must be customized for each patient, due to bone thickness and anatomical variations.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 29 (3) , e242439
Open AccessMiniscrew-assisted rapid palatal expansion (MARPE): Factors influencing planning
Objective: This cross-sectional study evaluated the bone thickness on mini-implants insertion site, the factors that influence the digital planning of MARPE appliance (miniscrew-assisted rapid palatal expansion), and its different designs. Methods: A total of 135 plannings were assessed regarding the size of the expander screw used, the positioning and the type of the mini-implant rings, and their location in relation to the teeth. Bone thickness measurements were assessed in the region of the mini-implants’ trajectory. Differences between the sexes was verified using the ANOVA test (5% significance). Results: 73 cases were planned with 4 mini-implants and 62 cases, with 6 mini-implants. In 90% of cases, teeth #16 and #26 were used as supports, and the most used expander screw was 13mm (64.1% of cases). The anterior mini-implants of conventional MARPE showed more pronounced insertion in bone in males (5.9 ± 2mm; p= 0.025). The extra mini-implants (anterior region) were inserted with greater bone thickness in males (11.1 ± 2.3mm) compared to females (9.9 ± 1.8mm; p=0.041). A greater bone thickness was observed in males (10.1 ± 2.1 mm) when using mini-implants in the paramedian region. Conclusion: Additional rings allow more pronounced bone insertion. Male patients had greater bone thickness, which may be related to greater difficulty in opening the sutures. The alveolar process region seems to be a satisfactory site for mini-implants to those patients with reduced bone thickness in the paramedian posterior region. MARPE appliance must be customized for each patient, due to bone thickness and anatomical variations.
- 30 November 2023
- Published by Dental Press International in Clinical Orthodontics
- Vol. 22 (5) , 50-57
Corticoperfurações na sutura intermaxilar: uma nova abordagem associada ao MARPE
OBJETIVO: Apresentar uma nova abordagem (Protocolo Andrade) para casos complexos de MARPE. DESCRIÇÃO: Esse protocolo consiste em perfurações guiadas da sutura intermaxilar, a fim de reduzir a resistência dessa sutura (região anterior da maxila). A região recebe de duas a três perfurações com broca de corticoperfuração de 1,5 mm de diâmetro, fragilizando até a parede cortical do canal nasopalatino. A guia utilizada possui um stop, com o objetivo de não permitir que a broca entre no canal nasopalatino e lesione o nervo nasopalatino. CONCLUSÃO: Esse protocolo eleva as chances de sucesso da técnica MARPE, devido à fragilização na região de maior volume ósseo da maxila. Além disso, para os casos de expansão maxilar por indicação respiratória, essa técnica garante uma abertura paralela e em assoalho da cavidade nasal, com melhores benefícios para a respiração.
- 30 November 2023
- Published by Dental Press International in Clinical Orthodontics
- Vol. 22 (5) , 50-57
Corticoperfurações na sutura intermaxilar: uma nova abordagem associada ao MARPE
OBJETIVO: Apresentar uma nova abordagem (Protocolo Andrade) para casos complexos de MARPE. DESCRIÇÃO: Esse protocolo consiste em perfurações guiadas da sutura intermaxilar, a fim de reduzir a resistência dessa sutura (região anterior da maxila). A região recebe de duas a três perfurações com broca de corticoperfuração de 1,5 mm de diâmetro, fragilizando até a parede cortical do canal nasopalatino. A guia utilizada possui um stop, com o objetivo de não permitir que a broca entre no canal nasopalatino e lesione o nervo nasopalatino. CONCLUSÃO: Esse protocolo eleva as chances de sucesso da técnica MARPE, devido à fragilização na região de maior volume ósseo da maxila. Além disso, para os casos de expansão maxilar por indicação respiratória, essa técnica garante uma abertura paralela e em assoalho da cavidade nasal, com melhores benefícios para a respiração.
- 15 May 2023
- Published by Dental Press International in Clinical Orthodontics
- Vol. 22 (2) , 60-71
Anel esquelético: um novo recurso para casos complexos
Bem vindo ao DentalGO a plataforma online dos melhores dentistas
- 15 May 2023
- Published by Dental Press International in Clinical Orthodontics
- Vol. 22 (2) , 60-71
Anel esquelético: um novo recurso para casos complexos
Bem vindo ao DentalGO a plataforma online dos melhores dentistas
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 28 (4) , e2322220
Short-term assessment of pain and discomfort during rapid maxillary expansion with tooth-bone-borne and tooth-borne appliances: randomized clinical trial
Objective: The aim of this randomized clinical trial was to evaluate and compare, during the first week of rapid maxillary expansion (RME), the impact caused by two types of appliances: Hyrax and Hybrid Hyrax. Methods: Forty-two patients who met the eligibility criteria (aged 11-14 years, with transverse maxillary deficiency, posterior crossbite, and presence of maxillary first premolars and first permanent molars) were selected and randomly divided into two groups: TBB GROUP (tooth-bone-borne expander), treated with Hybrid Hyrax (12 females and 9 males, mean age 13.3 ± 1.3 years), and TB GROUP (tooth-borne expander), treated with Hyrax (5 females and 16 males, mean age 13.3 ± 1.4 years). Pain and discomfort were assessed in two times: after the first day of activation (T1) and four days after, by means of the numerical rate scale and the instrument MFIQ (Mandibular Functional Impairment Questionnaire). Descriptive statistics and the Mann-Whitney test were used for comparison between groups and between sexes. A 5% significance level was adopted. Results: Both appliances had a negative impact, generating pain and discomfort, and reducing functional capacity. However, the scores obtained were of low intensity and no significant differences were observed between the groups. Considering sexes, there were statistically significant differences, with the female sex presenting higher scores for pain and functional limitation. Conclusions: Despite causing impact in pain and increase in the functional limitation, these changes were of low intensity, with no statistical difference between the groups. Females were more sensitive to the impact caused by the RME.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 28 (4) , e2322220
Open AccessShort-term assessment of pain and discomfort during rapid maxillary expansion with tooth-bone-borne and tooth-borne appliances: randomized clinical trial
Objective: The aim of this randomized clinical trial was to evaluate and compare, during the first week of rapid maxillary expansion (RME), the impact caused by two types of appliances: Hyrax and Hybrid Hyrax. Methods: Forty-two patients who met the eligibility criteria (aged 11-14 years, with transverse maxillary deficiency, posterior crossbite, and presence of maxillary first premolars and first permanent molars) were selected and randomly divided into two groups: TBB GROUP (tooth-bone-borne expander), treated with Hybrid Hyrax (12 females and 9 males, mean age 13.3 ± 1.3 years), and TB GROUP (tooth-borne expander), treated with Hyrax (5 females and 16 males, mean age 13.3 ± 1.4 years). Pain and discomfort were assessed in two times: after the first day of activation (T1) and four days after, by means of the numerical rate scale and the instrument MFIQ (Mandibular Functional Impairment Questionnaire). Descriptive statistics and the Mann-Whitney test were used for comparison between groups and between sexes. A 5% significance level was adopted. Results: Both appliances had a negative impact, generating pain and discomfort, and reducing functional capacity. However, the scores obtained were of low intensity and no significant differences were observed between the groups. Considering sexes, there were statistically significant differences, with the female sex presenting higher scores for pain and functional limitation. Conclusions: Despite causing impact in pain and increase in the functional limitation, these changes were of low intensity, with no statistical difference between the groups. Females were more sensitive to the impact caused by the RME.
- 15 November 2022
- Published by Dental Press International in Clinical Orthodontics
- Vol. 21 (5) , 32-41
Aparelhos ortodônticos impressos em metal: técnica Printed Orthodontics
Bem vindo ao DentalGO a plataforma online dos melhores dentistas
- 15 November 2022
- Published by Dental Press International in Clinical Orthodontics
- Vol. 21 (5) , 32-41
Aparelhos ortodônticos impressos em metal: técnica Printed Orthodontics
Bem vindo ao DentalGO a plataforma online dos melhores dentistas
- 19 July 2021
- Published by Dental Press International in Revista Clínica de Ortodontia Dental Press
- Vol. 20 (3) , 68-75
Aparelhos ortodônticos sobre mini-implantes: como proteger a região peri-implantar?
- 19 July 2021
- Published by Dental Press International in Revista Clínica de Ortodontia Dental Press
- Vol. 20 (3) , 68-75
Aparelhos ortodônticos sobre mini-implantes: como proteger a região peri-implantar?
- Open Access
- 21 June 2021
- Published by Springer Nature in Progress in Orthodontics
- Vol. 22 (1) , 1-12
Stress distribution and displacement of three different types of micro-implant assisted rapid maxillary expansion (MARME): a three-dimensional finite element study
Background/objective: Until 2010, adults underwent surgical treatment for maxillary expansion; however, with the advent of micro-implant-assisted rapid maxillary expansion (MARME), the availability of less invasive treatment options has increased. Nevertheless, individuals with severe transverse maxillary deficiency do not benefit from this therapy. This has aroused interest in creating a new device that allows the benefit of maxillary expansion for these individuals. The aim of this study was to evaluate the efficacy of three MARME models according to tension points, force distribution, and areas of concentration in the craniofacial complex when transverse forces are applied using finite element analysis. Materials and methods: Digital modeling of the three MARME models was performed. Model A comprised five components: one body screw expander and four adjustable arms with rings for mini-implant insertion. These arms have an individualized height adjustment that allows MARME positioning according to the patient’s palatal anatomy, thereby preventing body screw expander collision with the lateral mucosa in severe cases of maxillary deficiency. Model B was a maxillary expander with screw rings joined to the body, and model C was similar to model B, except that model C had open rings for the insertion of the mini-implants. Through the MEF (Ansys software), the stresses, distribution, and area of concentration of the stresses were evaluated when transverse forces of 7.85 N were applied. Results: The three models maintained the following pattern: model C presented weak stress peaks with limited distribution and lower concentration area, model B obtained median stress peaks with better distribution when compared to that of model C, and model A showed better stress distribution and larger concentration area. In model A, tensions were located in the lateral lamina of the pterygoid process, which is an important site for maxillary expansion. The limitation of the present study was that it did not include the periodontal tissues and muscles in the finite element method evaluation. Conclusions: Model A showed the best stress distribution conditions. In cases of severe atresia, model A seems to be an excellent option.
- 21 June 2021
- Published by Springer Nature in Progress in Orthodontics
- Vol. 22 (1) , 1-12
Open AccessStress distribution and displacement of three different types of micro-implant assisted rapid maxillary expansion (MARME): a three-dimensional finite element study
Background/objective: Until 2010, adults underwent surgical treatment for maxillary expansion; however, with the advent of micro-implant-assisted rapid maxillary expansion (MARME), the availability of less invasive treatment options has increased. Nevertheless, individuals with severe transverse maxillary deficiency do not benefit from this therapy. This has aroused interest in creating a new device that allows the benefit of maxillary expansion for these individuals. The aim of this study was to evaluate the efficacy of three MARME models according to tension points, force distribution, and areas of concentration in the craniofacial complex when transverse forces are applied using finite element analysis. Materials and methods: Digital modeling of the three MARME models was performed. Model A comprised five components: one body screw expander and four adjustable arms with rings for mini-implant insertion. These arms have an individualized height adjustment that allows MARME positioning according to the patient’s palatal anatomy, thereby preventing body screw expander collision with the lateral mucosa in severe cases of maxillary deficiency. Model B was a maxillary expander with screw rings joined to the body, and model C was similar to model B, except that model C had open rings for the insertion of the mini-implants. Through the MEF (Ansys software), the stresses, distribution, and area of concentration of the stresses were evaluated when transverse forces of 7.85 N were applied. Results: The three models maintained the following pattern: model C presented weak stress peaks with limited distribution and lower concentration area, model B obtained median stress peaks with better distribution when compared to that of model C, and model A showed better stress distribution and larger concentration area. In model A, tensions were located in the lateral lamina of the pterygoid process, which is an important site for maxillary expansion. The limitation of the present study was that it did not include the periodontal tissues and muscles in the finite element method evaluation. Conclusions: Model A showed the best stress distribution conditions. In cases of severe atresia, model A seems to be an excellent option.