AZAmmar Zeghloul

Ammar Zeghloul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ammar Zeghloul has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Abbas H. Hasan

    Faculty of Science and Engineering, University of Hull-Chemical Engineering, Hull, UK

    1 shared publication
  • Abdelsalam Al Sarkhi

    Mechanical Engineering Department, Center for Integrative Petroleum Research, King Fahd University of Petroleum & Minerals, Dhahran, Saudi Arabia

    1 shared publication
  • Abdelwahid Azzi

    Faculty of Mechanical and Process Engineering, Université des Sciences et de la Technologie Houari Boumediène, BP 32 El Alia, Algiers 16111, Algeria

    1 shared publication
  • Hiba Bouyahiaoui

    Faculty of Mechanical and Process Engineering, University of Sciences and TechnologyHouari Boumedien, BP 32 El Alia, Bab Ezzouar, Algiers 16111, Algeria

    1 shared publication

Latest Publications

  • Experimental Investigation of the Vertical Upward Single- and Two-Phase Flow Pressure Drops Through Gate and Ball Valves

    by Ammar Zeghloul, Hiba Bouyahiaoui, Abdelwahid Azzi, Abbas H. Hasan, Abdelsalam Al-Sarkhi

    This paper presents an experimental investigation of the pressure drop (DP) through valves in vertical upward flows. Experiments were carried out using a 1¼″ (DN 32) ball and gate valve. Five opening areas have been investigated from fully open to the nearly fully closed valve, using air with a superficial velocity of 0–3.5 m/s and water 0.05–0.91 m/s. These ranges cover single-phase and the bubbly, slug and churn two-phase flow regimes. It was found that for the single-phase flow experiments, the valve coefficient increases with the valve opening and is the same, in both valves, for the openings smaller than 40%. The single-phase pressure drop increases with the liquid flowrate and decreases with the opening area. The two-phase flow pressure drop was found considerably increased by reducing the opening area for both valves. It reaches its maximum values at 20% opening for the ball valve and 19% opening for the gate valve. It was also inferred that at fully opening condition, the two-phase flow multiplier, for both valves, has been found close to unity for most of the tested flow conditions. For 40 and 20% valve openings the two-phase multiplier decreases in the power-law with liquid holdup for the studied flow conditions. Models proposed originally for evaluating the pressure drop through an orifice in single-phase and two-phase flows were also applied and assessed in the present experimental data.