ACAndrei Dragos Cumpanas

Andrei Dragos Cumpanas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrei Dragos Cumpanas has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Warm irrigation fluid effect on Thulium fiber laser (TFL) ablation of uroliths

    by Andrei D. Cumpanas, Nitesh Katta, Thao N. Vu, Yi Xi Wu, Antonio R. H. Gorgen, Mariah C. Hernandez, Kelvin Vo, Sohrab N. Ali, Zachary E. Tano, Pengbo Jiang, et al.

    Prior laser studies have demonstrated that as the temperature of a medium increases, the amount of energy delivered to the target increases. We sought to investigate the role of irrigation fluid temperature on Thulium fiber laser (TFL) urolith ablation. 360 calculi were divided in vitro according to chemical composition: calcium oxalate monohydrate (COM), cystine (CYS), struvite (STR), calcium phosphate (CAP), uric acid (UA), and calcium oxalate dihydrate (COD). A 200 μm TFL was placed directly on each stone, while immersed in 0.9% NaCl at four different temperatures (25 C, 37 C, 44 C, 60 C) and a single laser pulse administered at distinct energy settings (0.1 J, 0.5 J, 1.5 J). Optical coherence tomography assessed the resulting ablation cone volume. Mean stone volume and porosity were evaluated through ANOVA and Tukey post-hoc analysis. A multivariate generalized model for each composition accounted for the impact of fluid temperature and laser energy on stone ablation. Warmer fluid temperatures yielded greater ablation cone volumes for most energy settings, excluding UA stones. When accounting for chemical composition, higher tensile strength stones (COM, CYS) benefited most from warmer fluid in comparison to frangible stones (CAP, STR). The effects of increasing fluid temperature are modest relative to laser pulse energy as a large temperature increase (i.e. 7ºC) is equivalent to a minor energy increase (i.e. 0.1 J). For non-UA stones, TFL ablation efficiency increases with warmer irrigation fluid. The effect, albeit modest compared to laser pulse energy, was most notable for COM and CYS stones.


  • Development and Initial Evaluation of a Cost-Effective Force Sensor for Ureteroscopic Application

    by Bruce M. Gao, Jacob C. Tsai, Andrei D. Cumpanas, Jaime Altamirano-Villarroel, Seyedamirvala Saadat, Victor Pham, Evan Grohs, Yi Xi Wu, Zachary E. Tano, Sohrab N. Ali, et al.

    Purpose: Retrograde intrarenal surgery is the gold-standard treatment for most kidney stones. During ureteroscopy, ureteral access sheath insertion at forces greater than 8.0 Newtons (N) risks high-grade ureteral injury. To monitor force, our institution utilizes a unique, Bluetooth-equipped device (i.e., the University of California—Irvine Force Sensor). Given the unique nature of the force sensor, we sought to develop an inexpensive and accessible force sensor based on Boyle’s law and the specific amount of force required to compress an occluded 1.0 mL syringe. Materials and Methods: We evaluated three brands of 1.0 mL syringes. After setting the plunger at 1.0 mL, the syringe was occluded, and the syringe plunger was compressed. The syringe volume was recorded when the applied force on the plunger reached 4.0 N, 6.0 N, and 8.0 N. Multiple trials were performed to assess reliability and reproducibility. A method for applying this clinically was also developed. Results: The precise force thresholds identified for a 1.0 mL Luer-Lok™ Syringe (Becton Dickinson, Franklin Lakes, NJ) were 0.30 mL for 4.00 N, 0.20 mL for 6.00 N, and 0.15 mL for 8.00 N. The 1.0 mL Tuberculin Syringe and 1.0 mL Luer Slip Syringe were less precise, but compression from 1.0 to 0.40 mL, 0.25 mL, and 0.20 mL corresponded to force sensor readings that did not exceed 4.00 N, 6.00 N, and 8.00 N, respectively. Conclusions: Based on volume changes, 4.00 N, 6.00 N, and 8.00 N of force can be reliably and reproducibly achieved using an occluded 1.0 mL syringe.


  • Surgical Force: Initial Study and Clinical Implications in the Assessment of Ureteral Access Sheath Induced Injury

    by Seyed Amiryaghoub M. Lavasani, Allen Rojhani, Andrei Dragos Cumpanas, Kathryn Osann, Kalon L. Morgan, Mariah C. Hernandez, Amanda McCormac, Paul Piedras, Kelvin Vo, Antonio R. H. Gorgen, et al.

    Purpose: Ureteral access sheaths (UAS) pose the risk of severe ureteral injury. Our prior studies revealed forces ≤6 Newtons (N) prevent ureteral injury. Accordingly, we sought to define the force urologists and residents in training typically use when placing a UAS. Materials and Methods: Among urologists and urology residents attending two annual urological conferences in 2022, 121 individuals were recruited for the study. Participants inserted 12F, 14F, and 16F UAS into a male genitourinary model containing a concealed force sensor; they also provided demographic information. Analysis was completed using t -tests and Chi-square tests to identify group differences when passing a 16F sheath UAS. Participant traits associated with surpassing or remaining below a minimal force threshold were also explored through polychotomous logistic regression. Results: Participant force distributions were as follows: ≤4N (29%), >6N (45%), and >8N (32%). More years of practice were significantly associated with exerting >6N relative to forces between 4N and 6N; results for >8N relative to 4N and 8N were similar. Compared to high-volume ureteroscopists (those performing >20 ureteroscopies/month), physicians performing ≤20 ureteroscopies/month were significantly less likely to exert forces ≤4N ( p = 0.017 and p = 0.041). Of those surpassing 6N and 8N, 15% and 18%, respectively, were high-volume ureteroscopists. Conclusions: Despite years of practice or volume of monthly ureteroscopic cases performed, most urologists failed to pass 16F access sheaths within the ideal range of 4N to 6N (74% of participants) or within a predefined safe range of 4N to 8N (61% of participants).


  • Utilization of Re-VASC, the Novel Retroperitoneal Neovascularity Scoring System, for Characterization of T1a Small Renal Masses

    by Cameron Fateri, Bradley Roth, Sriram Rao, Akhil Peta, Luke Limfueco, Thanh-Lan Bui, Nina Kar, Justin Glavis-Bloom, Andrei Dragos Cumpanas, Jaime Landman, et al.

    Purpose: Early characterization of small (T1a, < 4 cm) renal masses is imperative for patient care and treatment planning. Renal biopsy is a sensitive and specific procedure that can accurately differentiate small renal masses as malignant or benign. However, it is an invasive procedure with a non-negligible complication rate and is not performed routinely at most institutions. In this study, we sought to apply the Re-VASC scoring system to T1a renal masses and analyzed whether it could differentiate these masses as benign or malignant. Methods: We obtained Institutional Review Board approval to retrospectively examine the records of all patients who presented to our single, urban academic referral center for surgical treatment of renal cell carcinoma (RCC). For the malignant group, patients with a diagnosis of T1a RCC from pathologic evaluation were included. Additionally, patients with a histopathological diagnosis of a T1a non-malignant renal mass (fat poor-angiomyolipoma or oncocytoma) were included in our benign group. Results: This study includes 57 benign and 69 malignant T1a renal tumors. Average size for benign and malignant masses were 2.47 and 2.63 respectively (p=0.267). Analysis demonstrated no significant difference between both groups in terms of sex, laterality, or size. The average Re-VASC score of benign and malignant masses was 0.175 and malignant masses was 0.784 respectively (p<0.001). Additionally, the Re-VASC score was independently associated with malignancy with an odds ratio of 2.223 (p=0.0109). Conclusion: The Re-VASC scoring system exhibits significantly greater values for malignant T1a renal masses when compared to benign masses. As a result, it shows promise as an adjunctive tool to renal biopsy for clinical decision-making. Further assessment of Re-VASC’s true efficacy as a diagnostic marker will include prospective evaluation of a larger multicenter population.


  • Endoscopic Technology for PCNL

    by Zachary E. Tano, Andrei D. Cumpanas, Ahmad Abdel-Aziz, Ralph V. Clayman

  • Evaluation of Renal Function and Stent Durability Following Resonance Stent Placement for Benign Disease

    by Rohit Bhatt, Kelvin Vo, Andrei Dragos Cumpanas, Kalon L. Morgan, Andrew Shin, Sohrab N. Ali, Allen Rojhani, Akhil Peta, Andrew Brevik, Zachary Edward Tano, et al.

    Introduction: The metal-based Resonance stent (RS) has traditionally been placed in patients with malignant ureteral obstruction; as such, the long-term utility of RS among patients with benign ureteral obstruction (BUO) remains underinvestigated. Methods: We retrospectively reviewed our database for patients with BUO who underwent RS placement between 2010 and 2020. The impact of chronic RS placement on renal function was evaluated by estimated serum creatinine-based glomerular filtration rate (eGFR), furosemide renal scan, and CT-based renal parenchymal volume measurement. The number of and reason for RS stent exchanges during the follow-up period, incidence of encrustation, and the average indwell time were recorded. A cost analysis of placing the RS vs a polymeric stent was performed. Results: Among 43 RS patients with BUO, at a mean follow-up of 26 months, there was no change in eGFR ( p = 0.99), parenchymal volume ( p = 0.44), or split renal function of the stent-bearing side on renal scan ( p = 0.48). The mean RS indwell time was 9.7 months. Eleven patients (26%) underwent premature stent replacement (6 cases) or removal (5 cases). Stents in 9 patients (32%) were encrusted, of which 4 (44%) required laser lithotripsy. Overall, 25 patients (58%) and 12 patients (28%) had a mean stent indwell time of ≥6 months and ≥12 months, respectively. Placing an RS resulted in a 52%, 37%, and 5.6% cost reduction compared with a regular polymeric stent placement, where it was exchanged every 6, 4, or 3 months, respectively. Conclusions: RS deployment in the patient with a BUO results in cost-effective maintenance of renal function and of renal parenchymal volume at a mean follow-up of 2 years; however, only 28% of patients fulfilled the 1-year criterion for RS indwell time.