LXLiyuan Xie

Liyuan Xie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liyuan Xie has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Enxi Zhao

    Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology , Hefei 230009, Anhui, China

    1 shared publication
  • Jingtao Dong

    Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology 1 , Hefei 230009, Anhui, China

    1 shared publication
  • Shuo Wang

    Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology , Hefei 230009, Anhui, China

    1 shared publication
  • Yangyang Li

    Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology , Hefei 230009, Anhui, China

    1 shared publication
  • Zhipeng Tian

    Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei, Anhui, China

    1 shared publication

Latest Publications

  • Open Access

    Carrier optical vortex interferometer using segmentation demodulation method for dynamic measurement of axisymmetric surface deformation

    by Jingtao Dong, Liyuan Xie, Shuo Wang, Enxi Zhao, Yangyang Li, Zhipeng Tian

    The dynamic measurement of surface deformation with an axisymmetric profile at nanometer- to micrometer-scale is of great interest in understanding micromechanical and thermophysical dynamics. We propose a carrier optical vortex interferometer (COVI) to measure such surface deformation dynamically by segmentation demodulation of the petal-like interferogram that is produced by the coaxial superposition of conjugated p-radial order Laguerre–Gaussian beams. Specifically, a rotating chopper placed at the exit of the interferometer introduces a carrier frequency in the absence of surface deformation. A camera placed behind the chopper uses a multi-ring segmentation detection scheme to produce a Doppler shift relative to the carrier frequency at the radius of each ring in the presence of axisymmetric surface deformation. Locating the Doppler shifts gives the surface deformation velocities at those radii. Thus, the dynamic surface deformation profile can be obtained by integrating the velocities over time. We reveal the basic principles of the carrier frequency and the Doppler shifts in the COVI theoretically. As a proof-of-concept, an external force-induced axisymmetric mechanical surface deformation is measured dynamically to demonstrate the validity of the COVI. The results show that the measurement error of the surface deformation velocity is within (−2.1, 1.1 nm/s) for the velocity ranging from 20 to 86 nm/s. The lower limit of the measurable velocity can reach 20 nm/s. The measurement error of the surface deformation profile is less than 2.5 nm for the amplitude of the surface deformation of 500 nm.