RLRui Li

Rui Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rui Li has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Preparation of Carbon Fiber Electrodes Modified with Silver Nanoparticles by Electroplating Method

    by Yuhang Wang, Rui Li, Tianyuan Hou, Zhenming Piao, Yanxin Lv, Changsheng Liu, Yi Xin

    To solve the problems of carbon fiber (CF) electrodes, including poor frequency response and large potential drift, CFs were subjected to a roughening pretreatment process combining thermal oxidation and electrochemical anodic oxidation and then modified with Ag nanoparticles (AgNPs) using electroplating to prepare a CF electric field sensor. The surface morphology of the as-prepared AgNP-CF electric field sensor was characterized via optical microscopy, scanning electron microscopy, XPS, and energy-dispersive spectroscopy, and its impedance, polarization drift, self-noise, and temperature drift values were determined. Results show that the surface modification of the AgNP-CF electric field sensor is uniform, and its specific surface area is considerably increased. The electrode potential drift, characteristic impedance, self-noise, and temperature drift are 52.1 µV/24 h, 3.6 Ω, 2.993 nV/√Hz@1 Hz, and less than 70 µV/°C, respectively. Additionally, the AgNP-CF electric field sensor demonstrates low polarization and high stability. In field and simulated ocean tests, the AgNP-CF electrode exhibits excellent performance in the field and underwater environments, which renders it promising for the measurement of the ocean and geoelectric fields owing to its advantages, such as low noise and high stability.

  • Ultra-low noise nanoporous Ag/AgCl electric field sensor for telluric electric field detection

    by Yuhang Wang, Zhenming Piao, Rui Li, Tianyuan Hou, Changsheng Liu, Yi Xin

    This paper presents an ultra-low noise nanoporous Ag/AgCl electric field sensor fabricated using a sol in situ composite method, aiming to address the issues of high noise and significant drift encountered in traditional electric field sensors during low-frequency signal measurements. By utilizing polyvinylpyrrolidone (PVP) sol to regulate the nucleation process of AgCl and combining it with nano-silver powder, nanoscale Ag/AgCl particles were prepared. Through the use of NaCl as a pore-forming agent, an electrode with a porous structure was developed. A double-layer porous semi-permeable membrane encapsulation structure is employed, which protects the electrode from external environmental damage without compromising its performance, thereby improving its stability and lifespan. Experimental results demonstrate that the electrode exhibits a low source resistance of 0.13 Ω, the 24-h drift of less than 12 μV, and the self-noise of 0.874 nV/√Hz@1 Hz, with the working frequency band ranging from 0.1 Hz to 100 kHz, showcasing excellent frequency response and stability. Field tests in electrical prospecting further validated the electrode's high accuracy and reliability in measuring apparent resistivity, apparent polarizability, and spontaneous potential. This technological breakthrough provides robust technical support for deep resource exploration and long-term geoelectric field monitoring.


  • All-Solid Ultralow Noise Electric Field Sensor Based on the Sol Adhesion Method for Telluric and Marine Electrode Field Detection

    by Yuhang Wang, Rui Li, Xuefeng Song, Junye Tong, Tianyuan Hou, Yi Xin, Yuan Wang

    The sol adhesion method prepared an all-solid ultralow noise electric field sensor. Compared with the sintering method, electrolysis method, and ball milling method, the content of Ag (silver) and AgCl (silver chloride) stays at a high-level amount, the mixture is more uniform and there are no impurities introduced in the fabrication process. Some experiments were designed to characterize the basic properties and electrochemical characteristics of the electrode. Scanning electron microscope (SEM) shows the produced Ag/AgCl (silver and silver chloride) has small particle sizes and a large contact area. The potential drifts of electrodes are less than $15~\mu $ V. The self-potential is less than $80~\mu $ V. Self-noise of the electrode is 1.99 nV/ $\surd $ Hz@1 Hz. Meanwhile, the electrode responds well to electric field signals from 0.1 Hz to 3 kHz and can detect small amplitude signals to 2 mV without distortion. The electrode has the advantages of low impedance, low noise, high sensitivity, and high stability. The self-potential test showed the Ag/AgCl electrodes spent less than 20 min to reach stability is at least three times faster than that of Cu, Ag, Pb/PbCl, and stainless-steel electrodes. Stability potential and range drift are at least 98% and 93% lower than that of other electrodes. In the telluric test, the signal amplitude is at least four times of Ag and Pb/PbCl electrodes. In the marine test, the signal amplitude value is 4 mV level with the noise amplitude value is 0.06 mV level. It shows the good performance of the electrodes. This study is of great significance in accurately measuring marine and telluric electric fields.


  • Wearable Sleep Monitoring System Based on Machine Learning Using Snoring Sound Signal

    by Yi Xin, Rui Li, Xuefeng Song, Yuqi Wang, Hanshuo Zhang, Zhiying Chen

    According to the obstructive sleep apnea Syndrome (OSAS), a wearable sleep monitoring system is designed based on machine learning using snoring sound signal. The system picks up snoring signal via bone conduction sensor, and calculates the apnea-hypopnea index (AHI). By analyzing the snoring signal in frequency domain, spectral entropy and other frequency-domain features are selected. Finally, the neural network classifier model is established. In the model, the input variables are eight frequency-domain features, and the output response is related to AHI value. Trained by machine learning, the result shows that the average accuracy in identifying the severity of the four kinds of OSAS categories is 59%. The system uses the measured data of snoring to analyze the symptoms of OSAS, so as to realize the preliminary forecast based on the snoring data. The system proposed in this paper has a good application development prospect in intelligent monitoring and medical instruments.