ZPZhenming Piao

Zhenming Piao

*This is an algorithmically generated author record based on publicly available information.

Zhenming Piao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Biomimetic Tympanic Cavity PVDF Hydrophone for Low-Frequency Bioacoustic Monitoring in Marine Aquaculture

    by Tianyuan Hou, Zhenming Piao, Yuhang Wang, Yi Xin

    Underwater acoustic monitoring is a critical technology for marine resource development and modern aquaculture. The performance of acoustic sensors directly determines the effectiveness of biological behavior tracking in complex marine environments. This paper presents the design, fabrication, and characterization of a custom hydrophone utilizing a polyvinylidene fluoride (PVDF) piezoelectric film configured in a biomimetic tympanic cavity structure. Operating on the direct piezoelectric effect, the device employs a pre-tensioned PVDF diaphragm integrated with a dedicated charge amplifier circuit to condition high-impedance signals. Laboratory calibrations demonstrate a stable frequency response (with a sensitivity variation within ±1 dB) in the low-frequency range (1–200 Hz) with an average acoustic pressure sensitivity of approximately −206 dB (re 1 V/μPa), providing a higher relative voltage gain compared to a commercial reference hydrophone with a nominal sensitivity of −210 dB (re 1 V/μPa). Furthermore, extensive field evaluations were conducted in a marine net pen to analyze acoustic data across multiple fish feeding scenarios (baseline, pre-feeding, active feeding, and post-feeding). The proposed custom hydrophone exhibited a superior dynamic range and successfully locked onto a 24.4 Hz Golden Pompano (Trachinotus blochii) bioacoustic signature, maintaining remarkable feature stability even after active feeding ceased. This study validates the efficacy of the biomimetic PVDF hydrophone for low-frequency acoustic detection, providing a robust hardware foundation for automated behavioral recognition systems in aquaculture.


  • Open Access

    Low-Frequency Piezoelectric Hydrophone with High Sensitivity Based on a Piston Structure

    by Zhenming Piao, Tianyuan Hou, Yuhang Wang, Junye Tong, Hamadullah Panhwar, Yanxin Lv, Yi Xin

    Low-frequency hydrophones are used to detect underwater low-frequency acoustic signals and are widely applied in marine science, resource exploration, environmental monitoring, and military operations. Their primary advantage lies in the fact that low-frequency acoustic waves experience less attenuation in water, enabling long-distance detection. This characteristic makes them indispensable for long-range and wide-area sensing. In this study, a piston-structured hydrophone using a stack of lead zirconate titanate (PZT) piezoelectric ceramic sheets is designed. Finite element simulation analysis is used to derive the output voltage variation in the piezoelectric ceramic stack as a function of its thickness and end-face diameter. The piston-structured hydrophone is then designed accordingly. Results show that the piston structure, combined with the longitudinal stacking of PZT piezoelectric ceramic sheets, enhances the sensitivity of the piezoelectric hydrophone. The prepared hydrophone has a directivity of 360° in the operating frequency range of 1 Hz to 1 kHz, as well as a flat frequency response and high sensitivity of −161 dB. These research results indicate that the proposed sonar design provides valuable reference for the development of low-frequency sonar with higher sensitivity, which is of great significance to the development of marine science.


  • Open Access

    Preparation of Carbon Fiber Electrodes Modified with Silver Nanoparticles by Electroplating Method

    by Yuhang Wang, Rui Li, Tianyuan Hou, Zhenming Piao, Yanxin Lv, Changsheng Liu, Yi Xin

    To solve the problems of carbon fiber (CF) electrodes, including poor frequency response and large potential drift, CFs were subjected to a roughening pretreatment process combining thermal oxidation and electrochemical anodic oxidation and then modified with Ag nanoparticles (AgNPs) using electroplating to prepare a CF electric field sensor. The surface morphology of the as-prepared AgNP-CF electric field sensor was characterized via optical microscopy, scanning electron microscopy, XPS, and energy-dispersive spectroscopy, and its impedance, polarization drift, self-noise, and temperature drift values were determined. Results show that the surface modification of the AgNP-CF electric field sensor is uniform, and its specific surface area is considerably increased. The electrode potential drift, characteristic impedance, self-noise, and temperature drift are 52.1 µV/24 h, 3.6 Ω, 2.993 nV/√Hz@1 Hz, and less than 70 µV/°C, respectively. Additionally, the AgNP-CF electric field sensor demonstrates low polarization and high stability. In field and simulated ocean tests, the AgNP-CF electrode exhibits excellent performance in the field and underwater environments, which renders it promising for the measurement of the ocean and geoelectric fields owing to its advantages, such as low noise and high stability.

  • Ultra-low noise nanoporous Ag/AgCl electric field sensor for telluric electric field detection

    by Yuhang Wang, Zhenming Piao, Rui Li, Tianyuan Hou, Changsheng Liu, Yi Xin

    This paper presents an ultra-low noise nanoporous Ag/AgCl electric field sensor fabricated using a sol in situ composite method, aiming to address the issues of high noise and significant drift encountered in traditional electric field sensors during low-frequency signal measurements. By utilizing polyvinylpyrrolidone (PVP) sol to regulate the nucleation process of AgCl and combining it with nano-silver powder, nanoscale Ag/AgCl particles were prepared. Through the use of NaCl as a pore-forming agent, an electrode with a porous structure was developed. A double-layer porous semi-permeable membrane encapsulation structure is employed, which protects the electrode from external environmental damage without compromising its performance, thereby improving its stability and lifespan. Experimental results demonstrate that the electrode exhibits a low source resistance of 0.13 Ω, the 24-h drift of less than 12 μV, and the self-noise of 0.874 nV/√Hz@1 Hz, with the working frequency band ranging from 0.1 Hz to 100 kHz, showcasing excellent frequency response and stability. Field tests in electrical prospecting further validated the electrode's high accuracy and reliability in measuring apparent resistivity, apparent polarizability, and spontaneous potential. This technological breakthrough provides robust technical support for deep resource exploration and long-term geoelectric field monitoring.