Mingjuan Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mingjuan Ma has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Aiping Yao
Nanchang University
2 shared publications Hexuan Shi
Lanzhou University
1 shared publicationZihan Li
Lanzhou University
1 shared publication
Latest Publications
- Open Access
- 26 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (5) , 055021
Impact of MRI RF coil design on the RF-induced heating of medical implants: fixed B 1 + rms exposure versus normal operating mode
A direct comparison of the impact of RF coil design under specific absorption rate and B 1 + rms limitations are investigated and quantified using RF coils of different geometries and topologies at 64 MHz and 128 MHz. The RF-induced in vivo electric field and power deposition of a 50 cm long pacemaker and 55 cm long deep brain stimulator (DBS) are evaluated within two anatomical models exposed with these RF coils. The associated uncertainty is quantified and analyzed under a fixed B 1 + rms incident and normal operating mode. For a fixed B 1 + rms incident, the in vivo incident field shows a much higher uncertainty (>5.6 dB) to the RF coil diameter compared to other design parameters (e.g. B 1 + rms field to the untested implant will lead to a large variation in the induced incident and power deposition of the implant, as a result, a larger safe margin when different coil designs (e.g. coil diameter) are considered.
- 26 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (5) , 055021
Open AccessImpact of MRI RF coil design on the RF-induced heating of medical implants: fixed B 1 + rms exposure versus normal operating mode
A direct comparison of the impact of RF coil design under specific absorption rate and B 1 + rms limitations are investigated and quantified using RF coils of different geometries and topologies at 64 MHz and 128 MHz. The RF-induced in vivo electric field and power deposition of a 50 cm long pacemaker and 55 cm long deep brain stimulator (DBS) are evaluated within two anatomical models exposed with these RF coils. The associated uncertainty is quantified and analyzed under a fixed B 1 + rms incident and normal operating mode. For a fixed B 1 + rms incident, the in vivo incident field shows a much higher uncertainty (>5.6 dB) to the RF coil diameter compared to other design parameters (e.g. B 1 + rms field to the untested implant will lead to a large variation in the induced incident and power deposition of the implant, as a result, a larger safe margin when different coil designs (e.g. coil diameter) are considered.
- 18 August 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (17) , 175019
A machine learning-based approach for RF transfer function modeling of active implantable medical electrodes at 3T MRI
Objective. The objective of this work is to propose a machine learning-based approach to rapidly and efficiently model the radiofrequency (RF) transfer function of active implantable medical (AIM) electrodes, and to overcome the limitations and drawbacks of traditional measurement methods when applied to heterogeneous tissue environments. Approach. AIM electrodes with different geometries and proximate tissue distributions were considered, and their RF transfer functions were modeled numerically. Machine learning algorithms were developed and trained with the simulated transfer function datasets for homogeneous and heterogeneous tissue distributions. The performance of the method was analyzed statistically and validated experimentally and numerically. A comprehensive uncertainty analysis was performed and uncertainty budgets were derived. Main results. The proposed method is able to predict the RF transfer function of AIM electrodes under different tissue distributions, with mean correlation coefficients r of 0.99 and 0.98 for homogeneous and heterogeneous environments, respectively. The results were successfully validated by experimental measurements (e.g. the uncertainty of less than 0.9 dB) and numerical simulation (e.g. transfer function uncertainty in vivo power deposition underestimation was observed near generic pacemakers when using a simplified homogeneous tissue model. Significance. Provide an efficient alternative of transfer function modeling, which allows a more realistic tissue distribution and the potential underestimation of in vivo RF-induced power deposition near the AIM electrode can be reduced.
- 18 August 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (17) , 175019
A machine learning-based approach for RF transfer function modeling of active implantable medical electrodes at 3T MRI
Objective. The objective of this work is to propose a machine learning-based approach to rapidly and efficiently model the radiofrequency (RF) transfer function of active implantable medical (AIM) electrodes, and to overcome the limitations and drawbacks of traditional measurement methods when applied to heterogeneous tissue environments. Approach. AIM electrodes with different geometries and proximate tissue distributions were considered, and their RF transfer functions were modeled numerically. Machine learning algorithms were developed and trained with the simulated transfer function datasets for homogeneous and heterogeneous tissue distributions. The performance of the method was analyzed statistically and validated experimentally and numerically. A comprehensive uncertainty analysis was performed and uncertainty budgets were derived. Main results. The proposed method is able to predict the RF transfer function of AIM electrodes under different tissue distributions, with mean correlation coefficients r of 0.99 and 0.98 for homogeneous and heterogeneous environments, respectively. The results were successfully validated by experimental measurements (e.g. the uncertainty of less than 0.9 dB) and numerical simulation (e.g. transfer function uncertainty in vivo power deposition underestimation was observed near generic pacemakers when using a simplified homogeneous tissue model. Significance. Provide an efficient alternative of transfer function modeling, which allows a more realistic tissue distribution and the potential underestimation of in vivo RF-induced power deposition near the AIM electrode can be reduced.