GMGeorgios Mentzelopoulos

Georgios Mentzelopoulos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Georgios Mentzelopoulos has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating and benchmarking the EEG signal quality of high-density, dry MXene-based electrode arrays against gelled Ag/AgCl electrodes

    by Brian Erickson, Ryan Rich, Sneha Shankar, Brian Kim, Nicolette Driscoll, Georgios Mentzelopoulos, Guadalupe Fernandez-Nuñez, Flavia Vitale, John D Medaglia

    Objective. To evaluate the signal quality of dry MXene-based electrode arrays (also termed ‘MXtrodes’) for electroencephalographic (EEG) recordings where gelled Ag/AgCl electrodes are a standard. Approach. We placed 4 × 4 MXtrode arrays and gelled Ag/AgCl electrodes on different scalp locations. The scalp was cleaned with alcohol and rewetted with saline before application. We recorded from both electrode types simultaneously while participants performed a vigilance task. Main results. The root mean squared amplitude of MXtrodes was slightly higher than that of Ag/AgCl electrodes (.24–1.94 uV). Most MXtrode pairs had slightly lower broadband spectral coherence (.05 to .1 dB) and Delta- and Theta-band timeseries correlation (.05 to .1 units) compared to the Ag/AgCl pair (p < .001). However, the magnitude of correlation and coherence was high across both electrode types. Beta-band timeseries correlation and spectral coherence were higher between neighboring MXtrodes in the array (.81 to .84 units) than between any other pair (.70 to .75 units). This result suggests the close spacing of the nearest MXtrodes (3 mm) more densely sampled high spatial-frequency topographies. Event-related potentials were more similar between MXtrodes (ρ ⩾ .95) than equally spaced Ag/AgCl electrodes (ρ ⩽ .77, p < .001). Dry MXtrode impedance (x̄ = 5.15 KΩ cm2) was higher and more variable than gelled Ag/AgCl electrodes (x̄ = 1.21 KΩ cm2, p < .001). EEG was also recorded on the scalp across diverse hair types. Significance. Dry MXene-based electrodes record EEG at a quality comparable to conventional gelled Ag/AgCl while requiring minimal scalp preparation and no gel. MXtrodes can record independent signals at a spatial density four times higher than conventional electrodes, including through hair, thus opening novel opportunities for research and clinical applications that could benefit from dry and higher-density configurations.


  • A - 175 EEG Phase Can be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and SNR

    by Brian Kim, Brian A Erickson, Guadalupe Fernandez-Nuñez, John D Medaglia, Georgios Mentzelopoulos, Ryan R Rich, Flavia Vitale

    Electroencephalogram (EEG) phase can capture neural oscillation dynamics. Accordingly, EEG phase is a potential target for neurofeedback and brain-computer interfaces (BCIs). However, rigorous tests of the generalizability of real-time EEG phase are needed, requiring accurate phase estimates. We examined how cognitive states affect EEG phase prediction accuracy in the parieto-occipital alpha band. We identified datasets through public repositories. After preprocessing, we used the Educated Temporal Prediction Algorithm (ETP) to predict future peaks. We compared these predictions to the original signal, and defined accuracy from 0 to 100%. Our independent variable was cognitive state (eyes-open rest, eyes-closed rest, task), dependent variable was accuracy, and covariates were EEG instantaneous power and signal-to-noise ratio (SNR). We used a linear mixed-effects model, with random effects for dataset and individual. Across the 11 datasets, we had 543 participants and 1,641,074 predictions. There were no significant accuracy differences among the conditions (p < 1e-5), with a baseline accuracy of 59.07%. Power had an effect on accuracy, with a unit increase leading to a 13.1% increase in accuracy (p < 1e-5). SNR had an effect on accuracy, with an effect size of 0.46% (p < 1e-5), with a significant negative interaction with power with an effect size of −0.51% (p < 1e-5). Our results indicated that we could predict EEG phase accurately across cognitive conditions and datasets, with higher accuracy for high instantaneous band-power and SNR. Accordingly, real-time EEG phase experiments, closed-loop technologies, and BCIs should minimize external unwanted noise while targeting periods of high power, as opposed to manipulating experimental and cognitive conditions.