Logan M. Bateman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Logan M. Bateman has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Eric R. Henderson
Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
5 shared publications - Jonathan Thomas Elliott
Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States
3 shared publications Lillian A. Fisher
3 shared publications- Shudong Jiang
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
3 shared publications - Xu Cao
University of Wisconsin-Madison
3 shared publications - Yue Tang
Thayer School of Engineering at Dartmouth, Dartmouth College, Hanover, New Hampshire
3 shared publications
Latest Publications
- 5 August 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (18) , 2031-2039
Intraoperative Bone Perfusion Assessment Using Fluorescence Imaging in a Simulated Fracture Model
Background: Accurate debridement of poorly perfused bone and soft tissue is critical to reduce the risk of infection in open fracture or of recurrent fracture-related infection (FRI). However, accurate delineation of viable and nonviable tissue is difficult with current technology. The aim of this pilot study was to develop and evaluate an indocyanine green (ICG)-based dynamic contrast-enhanced fluorescence imaging (DCE-FI) strategy to provide intraoperative, objective, real-time information on bone perfusion using an osteotomy model in patients undergoing lower-extremity amputation. Methods: Fifteen patients who were ≥18 years of age and were undergoing lower-extremity amputation were included in this study. Perfusion-related kinetic parameters derived from DCE-FI, including maximum fluorescence intensity, ingress slope, and blood flow, were compared among 3 conditions reflecting sequentially increasing osseous damage: baseline, osteotomy (disruption of endosteal blood flow), and osteotomy plus periosteal stripping (disruption of endosteal and periosteal blood flow). Results: There were significant decreases in median values from baseline to after osteotomy alone for maximum intensity (96.2 to 58.9 relative fluorescence units [RFUs]), ingress slope (3.2 to 2.0 RFU/second), and blood flow (6.7 to 4.9 mL/min/100 g). Following osteotomy plus periosteal stripping, there were also significant decreases in median values for maximum intensity (12.0 RFU), ingress slope (0.2 RFU/s), and blood flow (0.8 mL/min/100 g). The Mann-Whitney U test confirmed a significant perfusion reduction (p < 0.001) in the tibial diaphysis due to these injuries. The areas under the curve (AUC) in the receiver operating characteristic (ROC) analysis for identifying periosteal stripping (compared with only osteotomy or no osseous damage) were 0.89 to 0.90, which were higher than the AUCs for identifying any osseous damage (osteotomy with or without periosteal stripping) compared with no damage, 0.75 to 0.82. Conclusions: This clinical study utilizing DCE-FI for intraoperative bone perfusion assessment in orthopaedic surgery demonstrated that kinetic variables derived from DCE-FI can effectively characterize and classify degradation of bone perfusion due to osteotomy and osteotomy plus periosteal stripping. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 5 August 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (18) , 2031-2039
Intraoperative Bone Perfusion Assessment Using Fluorescence Imaging in a Simulated Fracture Model
Background: Accurate debridement of poorly perfused bone and soft tissue is critical to reduce the risk of infection in open fracture or of recurrent fracture-related infection (FRI). However, accurate delineation of viable and nonviable tissue is difficult with current technology. The aim of this pilot study was to develop and evaluate an indocyanine green (ICG)-based dynamic contrast-enhanced fluorescence imaging (DCE-FI) strategy to provide intraoperative, objective, real-time information on bone perfusion using an osteotomy model in patients undergoing lower-extremity amputation. Methods: Fifteen patients who were ≥18 years of age and were undergoing lower-extremity amputation were included in this study. Perfusion-related kinetic parameters derived from DCE-FI, including maximum fluorescence intensity, ingress slope, and blood flow, were compared among 3 conditions reflecting sequentially increasing osseous damage: baseline, osteotomy (disruption of endosteal blood flow), and osteotomy plus periosteal stripping (disruption of endosteal and periosteal blood flow). Results: There were significant decreases in median values from baseline to after osteotomy alone for maximum intensity (96.2 to 58.9 relative fluorescence units [RFUs]), ingress slope (3.2 to 2.0 RFU/second), and blood flow (6.7 to 4.9 mL/min/100 g). Following osteotomy plus periosteal stripping, there were also significant decreases in median values for maximum intensity (12.0 RFU), ingress slope (0.2 RFU/s), and blood flow (0.8 mL/min/100 g). The Mann-Whitney U test confirmed a significant perfusion reduction (p < 0.001) in the tibial diaphysis due to these injuries. The areas under the curve (AUC) in the receiver operating characteristic (ROC) analysis for identifying periosteal stripping (compared with only osteotomy or no osseous damage) were 0.89 to 0.90, which were higher than the AUCs for identifying any osseous damage (osteotomy with or without periosteal stripping) compared with no damage, 0.75 to 0.82. Conclusions: This clinical study utilizing DCE-FI for intraoperative bone perfusion assessment in orthopaedic surgery demonstrated that kinetic variables derived from DCE-FI can effectively characterize and classify degradation of bone perfusion due to osteotomy and osteotomy plus periosteal stripping. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33306-17
Patient-specific arterial input function for accurate perfusion assessment in intraoperative fluorescence imaging
SignificanceThe arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green–based dynamic contrast-enhanced fluorescence imaging (DCE-FI).AimWe evaluate the impact of the AIF on perfusion assessment through DCE-FI.ApproachA total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF.ResultsIndividual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate (kep), maximum intensity (Imax), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant (Ktrans), and time to peak.ConclusionsIndividual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.
- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33306-17
Open AccessPatient-specific arterial input function for accurate perfusion assessment in intraoperative fluorescence imaging
SignificanceThe arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green–based dynamic contrast-enhanced fluorescence imaging (DCE-FI).AimWe evaluate the impact of the AIF on perfusion assessment through DCE-FI.ApproachA total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF.ResultsIndividual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate (kep), maximum intensity (Imax), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant (Ktrans), and time to peak.ConclusionsIndividual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.
- Open Access
- 14 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (06) , 066003-13
Real-time identification of life-threatening necrotizing soft-tissue infections using indocyanine green fluorescence imaging
Necrotizing soft-tissue infections (NSTIs) are aggressive infections with a cumulative case fatality rate near 21%1 (range, 6% to 76%).2 – 9 An NSTI occurs when highly virulent, exotoxin-producing bacteria are introduced to muscle, fascia, or subcutaneous tissue from penetrating wounds or following relatively minor, non-penetrating soft tissue injuries. NSTIs may be polymicrobial (i.e., caused by mixed aerobic/anaerobic pathogens) or monomicrobial (i.e., caused by a single pathogen such as group A Streptococcus, clostridial species, and others). Risk factors include blunt trauma, surgical incisions, insect bites, superficial cuts and abrasions, injection sites, muscle strains, pre-existing ulcers or fistulas, peri-rectal abscesses, burns, splinters, chicken pox, childbirth, penetrating injuries, diabetes, and other immunosuppressing conditions.6,9 – 15 Disruption of the barrier function provides microbial access to deeper soft tissues, though not all patients have such defined portals of bacterial entry, which makes them at higher risk for delayed diagnosis and treatment. Bacterial proliferation with concomitant exotoxin production leads to rapid disease progression, often within hours—causing widespread destruction of muscle, fascia, and skin; sepsis; multi-organ failure; and death. People of all ages and backgrounds can contract an NSTI, including otherwise healthy individuals, children, and neonates.8,10,11,15 The extreme virulence, morbidity, and mortality of NSTIs derive from the ability of causative bacteria to dysregulate microvascular function leading to irreversible tissue perfusion deficits9 and to commandeer the body’s acute-phase immune response such that the infection circumvents the body’s typical containment mechanisms against the spread of infection.16 The emergent nature and relatively low prevalence of NSTI (0.3 to 15.5 cases per 100,000 people, depending on the geographical location) make studying these infections and establishing advancements in care challenging.9
- 14 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (06) , 066003-13
Open AccessReal-time identification of life-threatening necrotizing soft-tissue infections using indocyanine green fluorescence imaging
Necrotizing soft-tissue infections (NSTIs) are aggressive infections with a cumulative case fatality rate near 21%1 (range, 6% to 76%).2 – 9 An NSTI occurs when highly virulent, exotoxin-producing bacteria are introduced to muscle, fascia, or subcutaneous tissue from penetrating wounds or following relatively minor, non-penetrating soft tissue injuries. NSTIs may be polymicrobial (i.e., caused by mixed aerobic/anaerobic pathogens) or monomicrobial (i.e., caused by a single pathogen such as group A Streptococcus, clostridial species, and others). Risk factors include blunt trauma, surgical incisions, insect bites, superficial cuts and abrasions, injection sites, muscle strains, pre-existing ulcers or fistulas, peri-rectal abscesses, burns, splinters, chicken pox, childbirth, penetrating injuries, diabetes, and other immunosuppressing conditions.6,9 – 15 Disruption of the barrier function provides microbial access to deeper soft tissues, though not all patients have such defined portals of bacterial entry, which makes them at higher risk for delayed diagnosis and treatment. Bacterial proliferation with concomitant exotoxin production leads to rapid disease progression, often within hours—causing widespread destruction of muscle, fascia, and skin; sepsis; multi-organ failure; and death. People of all ages and backgrounds can contract an NSTI, including otherwise healthy individuals, children, and neonates.8,10,11,15 The extreme virulence, morbidity, and mortality of NSTIs derive from the ability of causative bacteria to dysregulate microvascular function leading to irreversible tissue perfusion deficits9 and to commandeer the body’s acute-phase immune response such that the infection circumvents the body’s typical containment mechanisms against the spread of infection.16 The emergent nature and relatively low prevalence of NSTI (0.3 to 15.5 cases per 100,000 people, depending on the geographical location) make studying these infections and establishing advancements in care challenging.9
- Open Access
- 1 January 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (01) , 016001-12
Automatic correction of motion artifact in dynamic contrast-enhanced fluorescence imaging during open orthopedic surgery
Infection following trauma is one of the most prevalent and challenging complications faced by orthopedic surgeons. Inadequate tissue perfusion plays a critical role in this complication since poorly perfused bone can be a nidus for bacterial biofilm formation creating resistance to antibiotics.1,2 These biofilms make treatment of infections difficult as they increase the bacteria’s ability to evade the immune system, share antibiotic resistant genes, and proliferate additional planktonic bacteria.3 Because of this, management of open fractures and fracture-related infection relies on aggressive and thorough debridement in an effort to remove all poorly perfused bone.4,5 However, there is a limited number of imaging tools to objectively inform bone perfusion and guide debridement.
- 1 January 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (01) , 016001-12
Open AccessAutomatic correction of motion artifact in dynamic contrast-enhanced fluorescence imaging during open orthopedic surgery
Infection following trauma is one of the most prevalent and challenging complications faced by orthopedic surgeons. Inadequate tissue perfusion plays a critical role in this complication since poorly perfused bone can be a nidus for bacterial biofilm formation creating resistance to antibiotics.1,2 These biofilms make treatment of infections difficult as they increase the bacteria’s ability to evade the immune system, share antibiotic resistant genes, and proliferate additional planktonic bacteria.3 Because of this, management of open fractures and fracture-related infection relies on aggressive and thorough debridement in an effort to remove all poorly perfused bone.4,5 However, there is a limited number of imaging tools to objectively inform bone perfusion and guide debridement.
- Open Access
- 5 January 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (08) , 082802-7
Preclinical evaluation of molecularly targeted fluorescent probes in perfused amputated human limbs
SignificanceThis first-in-kind, perfused, and amputated human limb model allows for the collection of human data in preclinical selection of lead fluorescent agents. The model facilitates more accurate selection and testing of fluorophores with human-specific physiology, such as differential uptake and signal in fat between animal and human models with zero risk to human patients. Preclinical testing using this approach may also allow for the determination of tissue toxicity, clearance time of fluorophores, and the production of harmful metabolites.AimThis study was conducted to determine the fluorescence intensity values and tissue specificity of a preclinical, nerve tissue targeted fluorophore, as well as the capacity of this first-in-kind model to be used for lead fluorescent agent selection in the future.ApproachFreshly amputated human limbs were perfused for 30 min prior to in situ and ex vivo imaging of nerves with both open-field and closed-field commercial fluorescence imaging systems.ResultsIn situ, open-field imaging demonstrated a signal-to-background ratio (SBR) of 4.7 when comparing the nerve with adjacent muscle tissue. Closed-field imaging demonstrated an SBR of 3.8 when the nerve was compared with adipose tissue and 4.8 when the nerve was compared with muscle.ConclusionsThis model demonstrates an opportunity for preclinical testing, evaluation, and selection of fluorophores for use in clinical trials as well as an opportunity to study peripheral pathologies in a controlled environment.
- 5 January 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (08) , 082802-7
Open AccessPreclinical evaluation of molecularly targeted fluorescent probes in perfused amputated human limbs
SignificanceThis first-in-kind, perfused, and amputated human limb model allows for the collection of human data in preclinical selection of lead fluorescent agents. The model facilitates more accurate selection and testing of fluorophores with human-specific physiology, such as differential uptake and signal in fat between animal and human models with zero risk to human patients. Preclinical testing using this approach may also allow for the determination of tissue toxicity, clearance time of fluorophores, and the production of harmful metabolites.AimThis study was conducted to determine the fluorescence intensity values and tissue specificity of a preclinical, nerve tissue targeted fluorophore, as well as the capacity of this first-in-kind model to be used for lead fluorescent agent selection in the future.ApproachFreshly amputated human limbs were perfused for 30 min prior to in situ and ex vivo imaging of nerves with both open-field and closed-field commercial fluorescence imaging systems.ResultsIn situ, open-field imaging demonstrated a signal-to-background ratio (SBR) of 4.7 when comparing the nerve with adjacent muscle tissue. Closed-field imaging demonstrated an SBR of 3.8 when the nerve was compared with adipose tissue and 4.8 when the nerve was compared with muscle.ConclusionsThis model demonstrates an opportunity for preclinical testing, evaluation, and selection of fluorophores for use in clinical trials as well as an opportunity to study peripheral pathologies in a controlled environment.