Yizhou Zhang
Yizhou Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hao Yun
China Nuclear Power Operation Technology Co., Ltd., Minzu Road 1021, Wuhan 430073, China
3 shared publications - Jialu Cheng
KTH Royal Institute of Technology, Stockholm, Sweden
3 shared publications - Liang Wang
China Nuclear Power Operation Technology Co., Ltd., Minzu Road 1021, Wuhan 430073, China
3 shared publications - Nathaniel Taylor
KTH Royal Institute of Technology, Stockholm, Sweden
2 shared publications B. X. Yu
Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi'an, China
1 shared publication- Baoli Guo
National Center for Materials Service Safety, University of Science and Technology Beijing, Beijing 100083, China
1 shared publication
Latest Publications
- Open Access
- 5 August 2025
- Published by MDPI AG in Electronics
- Vol. 14 (15) , 3117
Transformer Winding Fault Locating Using Frequency Domain Reflectometry (FDR) Technology
Detecting power transformer winding degradations at an early stage is very important for the safe operation of nuclear power plants. Most transformer failures are caused by insulation breakdown; the winding turn-to-turn short circuit fault is frequently encountered. Experience has shown that routine testing techniques, e.g., winding resistance, leakage inductance, and sweep frequency response analysis (SFRA), are not sensitive enough to identify minor turn-to-turn short defects. The SFRA technique is effective only if the fault is in such a condition that the flux distribution in the core is prominently distorted. This paper proposes the frequency domain reflectometry (FDR) technique for detecting and locating transformer winding defects. FDR measures the wave impedance and its change along the measured windings. The wire over a plane model is selected as the transmission line model for the transformer winding. The effectiveness is verified through lab experiments on a twist pair cable simulating the transformer winding and field testing on a real transformer. The FDR technique successfully identified and located the turn-to-turn short fault that was not detected by other testing techniques. Using FDR as a complementary tool for winding condition assessment will be beneficial.
- 5 August 2025
- Published by MDPI AG in Electronics
- Vol. 14 (15) , 3117
Open AccessTransformer Winding Fault Locating Using Frequency Domain Reflectometry (FDR) Technology
Detecting power transformer winding degradations at an early stage is very important for the safe operation of nuclear power plants. Most transformer failures are caused by insulation breakdown; the winding turn-to-turn short circuit fault is frequently encountered. Experience has shown that routine testing techniques, e.g., winding resistance, leakage inductance, and sweep frequency response analysis (SFRA), are not sensitive enough to identify minor turn-to-turn short defects. The SFRA technique is effective only if the fault is in such a condition that the flux distribution in the core is prominently distorted. This paper proposes the frequency domain reflectometry (FDR) technique for detecting and locating transformer winding defects. FDR measures the wave impedance and its change along the measured windings. The wire over a plane model is selected as the transmission line model for the transformer winding. The effectiveness is verified through lab experiments on a twist pair cable simulating the transformer winding and field testing on a real transformer. The FDR technique successfully identified and located the turn-to-turn short fault that was not detected by other testing techniques. Using FDR as a complementary tool for winding condition assessment will be beneficial.
- Open Access
Influence of Chloride Concentration on Fretting Wear Behavior of Inconel 600 Alloy
The nickel-based alloy Inconel 600, strengthened by solution treatment, finds extensive application as a heat exchange pipe material in steam generators within nuclear power plants, owing to its exceptional resistance to high-temperature corrosion. However, fretting corrosion occurs at the contact points between the pipe and support frame due to gas–liquid flow, leading to wear damage. This study investigates the fretting wear behavior and damage mechanism of the nickel-based alloy Inconel 600 and 304 stainless steel friction pairs under point contact conditions in a water environment. Characterization was performed using laser confocal scanning microscopy and scanning electron microscopy equipped with energy-dispersive spectroscopy. Results indicate that the friction coefficient remains consistent across different chloride ion concentrations, while the wear volume increases with increasing chloride concentrations. Notably, friction coefficient oscillations are observed in the gross slip regime (GSR). Moreover, the stability of the oxide layer formed in water is compromised, diminishing its protective effect against wear. In the partial slip regime (PSR), friction coefficient oscillations are absent. An oxide layer forms within the wear scar, with significantly fewer cracks compared to those within the oxide layer in the GSR. It is worth noting that in GSR, the friction coefficient oscillates.
Open AccessInfluence of Chloride Concentration on Fretting Wear Behavior of Inconel 600 Alloy
The nickel-based alloy Inconel 600, strengthened by solution treatment, finds extensive application as a heat exchange pipe material in steam generators within nuclear power plants, owing to its exceptional resistance to high-temperature corrosion. However, fretting corrosion occurs at the contact points between the pipe and support frame due to gas–liquid flow, leading to wear damage. This study investigates the fretting wear behavior and damage mechanism of the nickel-based alloy Inconel 600 and 304 stainless steel friction pairs under point contact conditions in a water environment. Characterization was performed using laser confocal scanning microscopy and scanning electron microscopy equipped with energy-dispersive spectroscopy. Results indicate that the friction coefficient remains consistent across different chloride ion concentrations, while the wear volume increases with increasing chloride concentrations. Notably, friction coefficient oscillations are observed in the gross slip regime (GSR). Moreover, the stability of the oxide layer formed in water is compromised, diminishing its protective effect against wear. In the partial slip regime (PSR), friction coefficient oscillations are absent. An oxide layer forms within the wear scar, with significantly fewer cracks compared to those within the oxide layer in the GSR. It is worth noting that in GSR, the friction coefficient oscillates.
- Open Access
A Study of Frequency Domain Reflectometry Technique for High-Voltage Rotating Machine Winding Condition Assessment
Detecting and locating local degradations at an incipient stage is very important for mission-critical high-voltage rotating machines. One particular challenge in the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on the scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially created defects. These defects include turn-to-turn short, surface creepage, loose coils, insufficient end-winding spacing, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that FDR can identify and locate structural and insulation degradation in both shielded and unshielded objects with good sensitivity. This makes FDR a complementary technique for machine fault diagnosis and aging assessment.
Open AccessA Study of Frequency Domain Reflectometry Technique for High-Voltage Rotating Machine Winding Condition Assessment
Detecting and locating local degradations at an incipient stage is very important for mission-critical high-voltage rotating machines. One particular challenge in the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on the scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially created defects. These defects include turn-to-turn short, surface creepage, loose coils, insufficient end-winding spacing, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that FDR can identify and locate structural and insulation degradation in both shielded and unshielded objects with good sensitivity. This makes FDR a complementary technique for machine fault diagnosis and aging assessment.
- Open Access
- 9 August 2023
- Published by MDPI AG in Preprints.org
The Study of Frequency Domain Reflectometry Technique for High Voltage Rotating Machine Winding Condition Assessment
Detecting, especially locating local degradations at an incipient stage, is very important for mission-critical high voltage rotating machines. One particular challenge of the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially made defects. These defects include turn-to-turn short, surface creepage, loose coils, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that the FDR can identify and locate both structure and insulation degradations of both shielded and unshielded objects with good sensitivity. This makes the FDR a comprehensive tool for fault diagnosis and aging assessment.
- 9 August 2023
- Published by MDPI AG in Preprints.org
Open AccessThe Study of Frequency Domain Reflectometry Technique for High Voltage Rotating Machine Winding Condition Assessment
Detecting, especially locating local degradations at an incipient stage, is very important for mission-critical high voltage rotating machines. One particular challenge of the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially made defects. These defects include turn-to-turn short, surface creepage, loose coils, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that the FDR can identify and locate both structure and insulation degradations of both shielded and unshielded objects with good sensitivity. This makes the FDR a comprehensive tool for fault diagnosis and aging assessment.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 258-261
Analysis on turn-to-turn insulation of the secondary winding in Tesla transformer
A criterion to describe the turn-to-turn discharge of the secondary winding in Tesla transformers is presented. Factors which have influences on the turn-to-turn insulation of the winding such as the wire diameter, the wire distance, the void size, the purity of transformer oil and the insulation strength of the wire are researched based on this criterion. By theoretical calculation, the electric field enhancement factor (FEF) dependent on the wire diameter and the wire distance is presented. It is found that an optimum ratio of the wire diameter to the wire distance exists which corresponds to the minimum FEF. Via the Paschen's Curve, the electric breakdown strength (Eb) for voids with different sizes is deduced, and it is found that the existence of voids makes the discharge occur more easily due to void's lower Eb but if the size of a void is smaller than a certain value, it cannot affect the winding's turn-to-turn insulation. Through experiments, Eb of the traditional enamel wire and that of the three-layered insulation (TLI) wire are compared. The results show that Eb of the three-layered wire is basically two times of that of an enamel wire. Based on the results, suggestions to improve the insulation of the secondary winding in Tesla transformers are summarized.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 258-261
Analysis on turn-to-turn insulation of the secondary winding in Tesla transformer
A criterion to describe the turn-to-turn discharge of the secondary winding in Tesla transformers is presented. Factors which have influences on the turn-to-turn insulation of the winding such as the wire diameter, the wire distance, the void size, the purity of transformer oil and the insulation strength of the wire are researched based on this criterion. By theoretical calculation, the electric field enhancement factor (FEF) dependent on the wire diameter and the wire distance is presented. It is found that an optimum ratio of the wire diameter to the wire distance exists which corresponds to the minimum FEF. Via the Paschen's Curve, the electric breakdown strength (Eb) for voids with different sizes is deduced, and it is found that the existence of voids makes the discharge occur more easily due to void's lower Eb but if the size of a void is smaller than a certain value, it cannot affect the winding's turn-to-turn insulation. Through experiments, Eb of the traditional enamel wire and that of the three-layered insulation (TLI) wire are compared. The results show that Eb of the three-layered wire is basically two times of that of an enamel wire. Based on the results, suggestions to improve the insulation of the secondary winding in Tesla transformers are summarized.