Xiang Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiang Gao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Zheng Cao
National Synchrotron Radiation Laboratory University of Science and Technology of China Hefei China
2 shared publications - Gongfa Liu
National Synchrotron Radiation Laboratory University of Science and Technology of China Hefei China
1 shared publication Junfeng Gao
Oncology Department Hefei First People's Hospital Hefei China
1 shared publicationLei Ge
Oncology Department Hefei First People's Hospital Hefei China
1 shared publication- Yuanji Pei
National Synchrotron Radiation Laboratory University of Science and Technology of China Hefei China
1 shared publication
Latest Publications
- Open Access
- 12 September 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (2) , e14153
Multiscale spatial relationship‐based model for predicting bladder wall dose in pelvic radiotherapy
Purpose: This research aimed to develop a prediction model to assess bladder wall dosimetry during radiotherapy for patients with pelvic tumors, thereby facilitating the refinement and evaluation of radiotherapy treatment plans to mitigate bladder toxicity.Methods: Radiotherapy treatment plans of 49 rectal cancer patients and 45 gynecologic cancer patients were collected, and multiple linear regression analyses were used to generate prediction models for bladder wall dose parameters (, ). These models were based on the multiscale spatial relationship between the planning target volume (PTV) and the bladder or bladder wall. The proportion of bladder or bladder wall volume overlapped by the different distance expansions of the PTV was used as an indicator of the multiscale spatial relationship. The accuracy of these models was verified in a cohort of 12 new patients, with further refinement of radiotherapy treatment plans using the predicted values as optimization parameters. Model accuracy was assessed using root mean square error (RMSE) and mean percentage error (MPE).Results: Models derived from individual disease data outperformed those derived from combined datasets. Predicted bladder wall dose parameters were accurate, with the majority of initial calculated values for new patients falling within the 95% confidence interval of the model predictions. There was a robust correlation between the predicted and actual dose metrics, with a correlation coefficient of 0.943. Using the predicted values to optimize treatment plans significantly reduced bladder wall dose (p0.001), with bladder wall and decreasing by 2.27±0.80 Gy (5.8%±1.8%) and 2.96±2.05 cm3 (7.9%±5.4%), respectively.Conclusion: The formulated prediction model provides a valuable tool for predicting and minimizing bladder wall dose and for optimizing and evaluating radiotherapy treatment plans for pelvic tumor patients. This approach holds promise for reducing bladder toxicity and potentially improving patient outcomes.
- 12 September 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (2) , e14153
Open AccessMultiscale spatial relationship‐based model for predicting bladder wall dose in pelvic radiotherapy
Purpose: This research aimed to develop a prediction model to assess bladder wall dosimetry during radiotherapy for patients with pelvic tumors, thereby facilitating the refinement and evaluation of radiotherapy treatment plans to mitigate bladder toxicity.Methods: Radiotherapy treatment plans of 49 rectal cancer patients and 45 gynecologic cancer patients were collected, and multiple linear regression analyses were used to generate prediction models for bladder wall dose parameters (, ). These models were based on the multiscale spatial relationship between the planning target volume (PTV) and the bladder or bladder wall. The proportion of bladder or bladder wall volume overlapped by the different distance expansions of the PTV was used as an indicator of the multiscale spatial relationship. The accuracy of these models was verified in a cohort of 12 new patients, with further refinement of radiotherapy treatment plans using the predicted values as optimization parameters. Model accuracy was assessed using root mean square error (RMSE) and mean percentage error (MPE).Results: Models derived from individual disease data outperformed those derived from combined datasets. Predicted bladder wall dose parameters were accurate, with the majority of initial calculated values for new patients falling within the 95% confidence interval of the model predictions. There was a robust correlation between the predicted and actual dose metrics, with a correlation coefficient of 0.943. Using the predicted values to optimize treatment plans significantly reduced bladder wall dose (p0.001), with bladder wall and decreasing by 2.27±0.80 Gy (5.8%±1.8%) and 2.96±2.05 cm3 (7.9%±5.4%), respectively.Conclusion: The formulated prediction model provides a valuable tool for predicting and minimizing bladder wall dose and for optimizing and evaluating radiotherapy treatment plans for pelvic tumor patients. This approach holds promise for reducing bladder toxicity and potentially improving patient outcomes.
- Open Access
- 13 August 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (11) , e14115
Effect of metal implants and metal artifacts on back‐projected two‐dimensional entrance fluence determined by EPID dosimetry
Purpose: To evaluate the errors caused by metal implants and metal artifacts in the two‐dimensional entrance fluences reconstructed using the back‐projection algorithm based on electronic portal imaging device (EPID) images.Methods: The EPID in the Varian VitalBeam accelerator was used to acquire portal dose images (PDIs), and then commercial EPID dosimetry software was employed to reconstruct the two‐dimensional entrance fluences based on computed tomography (CT) images of the head phantoms containing interchangeable metal‐free/titanium/aluminum round bars. The metal‐induced errors in the two‐dimensional entrance fluences were evaluated by comparing the γ results and the pixel value errors in the metal‐affected regions. We obtained metal‐artifact‐free CT images by replacing the voxel values of non‐metal inserts with those of metal inserts in metal‐free CT images to evaluate the metal‐artifact‐induced errors.Results: The γ passing rates (versus PDIs obtained without a phantom in the beam field (PDIair), 2%/2 mm) for the back‐projected two‐dimensional entrance fluences of phantoms containing titanium or aluminum (BPTi/BPAl) were reduced from 92.4% to 90.5% and 90.6%, respectively, relative to the metal‐free phantom (BPmetal‐free). Titanium causes more severe metal artifacts in CT images than aluminum, and its removal resulted in a 0.0022 CU (median) reduction in the pixel value of BPTi artifact‐free relative to BPTi in the metal‐affected region. Moreover, the mean absolute error (MAE) and root mean square error (RMSE) decreased from 0.0050 CU and 0.0063 CU to 0.0034 CU and 0.0040 CU, respectively (vs. BPmetal‐free).Conclusion: Metal implants increase the errors in back‐projected two‐dimensional entrance fluences, and metals with higher electron densities cause more errors. For high‐electron‐density metal implants that produce severe metal artifacts (e.g., titanium), removing metal artifacts from the CT images can improve the accuracy of the two‐dimensional entrance fluences reconstructed by back‐projection algorithms.
- 13 August 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (11) , e14115
Open AccessEffect of metal implants and metal artifacts on back‐projected two‐dimensional entrance fluence determined by EPID dosimetry
Purpose: To evaluate the errors caused by metal implants and metal artifacts in the two‐dimensional entrance fluences reconstructed using the back‐projection algorithm based on electronic portal imaging device (EPID) images.Methods: The EPID in the Varian VitalBeam accelerator was used to acquire portal dose images (PDIs), and then commercial EPID dosimetry software was employed to reconstruct the two‐dimensional entrance fluences based on computed tomography (CT) images of the head phantoms containing interchangeable metal‐free/titanium/aluminum round bars. The metal‐induced errors in the two‐dimensional entrance fluences were evaluated by comparing the γ results and the pixel value errors in the metal‐affected regions. We obtained metal‐artifact‐free CT images by replacing the voxel values of non‐metal inserts with those of metal inserts in metal‐free CT images to evaluate the metal‐artifact‐induced errors.Results: The γ passing rates (versus PDIs obtained without a phantom in the beam field (PDIair), 2%/2 mm) for the back‐projected two‐dimensional entrance fluences of phantoms containing titanium or aluminum (BPTi/BPAl) were reduced from 92.4% to 90.5% and 90.6%, respectively, relative to the metal‐free phantom (BPmetal‐free). Titanium causes more severe metal artifacts in CT images than aluminum, and its removal resulted in a 0.0022 CU (median) reduction in the pixel value of BPTi artifact‐free relative to BPTi in the metal‐affected region. Moreover, the mean absolute error (MAE) and root mean square error (RMSE) decreased from 0.0050 CU and 0.0063 CU to 0.0034 CU and 0.0040 CU, respectively (vs. BPmetal‐free).Conclusion: Metal implants increase the errors in back‐projected two‐dimensional entrance fluences, and metals with higher electron densities cause more errors. For high‐electron‐density metal implants that produce severe metal artifacts (e.g., titanium), removing metal artifacts from the CT images can improve the accuracy of the two‐dimensional entrance fluences reconstructed by back‐projection algorithms.