Yufan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yufan Wang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Diyang Zou
School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China
1 shared publication Haoyuan Wang
Department of Orthopedics Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine Shanghai China
1 shared publication- Jie Zhao
Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication Mengjie Ying
Department of Orthopedics Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine Shanghai China
1 shared publication- Nan Zheng
School of Biomedical Engineering, Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication - Rongshan Cheng
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China
1 shared publication
Latest Publications
- 2 December 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (3) , 703-713
Multitask learning for automatic detection of meniscal injury on 3D knee MRI
Magnetic resonance imaging (MRI) of the knee is the recommended diagnostic method before invasive arthroscopy surgery. Nevertheless, interpreting knee MRI scans is a time‐consuming process that is vulnerable to inaccuracies and inconsistencies. We proposed a multitask learning network MCSNetatt which efficiently introduces segmentation prior features and enhances classification results through multiscale feature fusion and spatial attention modules. The MRI studies and subsequent arthroscopic diagnosis of 259 knees were collected retrospectively. Models were trained based on multitask loss with coronal and sagittal sequences and fused using logistic regression (LR). We visualized the network's interpretability by the gradient‐weighted class activation mapping method. The LR model achieved higher area under the curve and mean average precision of medial and lateral menisci than models trained on a single sagittal or coronal sequence. Our multitask model MCSNetat outperformed the single‐task model CNet and two clinicians in classification, with accuracy, precision, recall, F1‐score of 0.980, 1.000, 0.952, 0.976 for medial and 0.920, 0.905, 0.905, 0.905 for the lateral, respectively. With the assistance of model results and visualized saliency maps, both clinicians showed improvement in their diagnostic performance. Compared to the baseline segmentation model, our model improved dice similarity coefficient and the 95% Hausdorff distance (HD95) of the lateral meniscus for 2.3% and 0.860 mm in coronal images and 4.4% and 2.253 mm in sagittal images. Our multitask learning network quickly generated accurate clinicopathological classification and segmentation of knee MRI, demonstrating its potential to assist doctors in a clinical setting.
- 2 December 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (3) , 703-713
Multitask learning for automatic detection of meniscal injury on 3D knee MRI
Magnetic resonance imaging (MRI) of the knee is the recommended diagnostic method before invasive arthroscopy surgery. Nevertheless, interpreting knee MRI scans is a time‐consuming process that is vulnerable to inaccuracies and inconsistencies. We proposed a multitask learning network MCSNetatt which efficiently introduces segmentation prior features and enhances classification results through multiscale feature fusion and spatial attention modules. The MRI studies and subsequent arthroscopic diagnosis of 259 knees were collected retrospectively. Models were trained based on multitask loss with coronal and sagittal sequences and fused using logistic regression (LR). We visualized the network's interpretability by the gradient‐weighted class activation mapping method. The LR model achieved higher area under the curve and mean average precision of medial and lateral menisci than models trained on a single sagittal or coronal sequence. Our multitask model MCSNetat outperformed the single‐task model CNet and two clinicians in classification, with accuracy, precision, recall, F1‐score of 0.980, 1.000, 0.952, 0.976 for medial and 0.920, 0.905, 0.905, 0.905 for the lateral, respectively. With the assistance of model results and visualized saliency maps, both clinicians showed improvement in their diagnostic performance. Compared to the baseline segmentation model, our model improved dice similarity coefficient and the 95% Hausdorff distance (HD95) of the lateral meniscus for 2.3% and 0.860 mm in coronal images and 4.4% and 2.253 mm in sagittal images. Our multitask learning network quickly generated accurate clinicopathological classification and segmentation of knee MRI, demonstrating its potential to assist doctors in a clinical setting.
- Open Access
- 25 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1006
Development and Validation of a Novel In Vitro Joint Testing System for Reproduction of In Vivo Dynamic Muscle Force
In vitro biomechanical experiments utilizing cadaveric specimens are one of the most effective methods for rehearsing surgical procedures, testing implants, and guiding postoperative rehabilitation. Applying dynamic physiological muscle force to the specimens is a challenge to reconstructing the environment of bionic mechanics in vivo, which is often ignored in the in vitro experiment. The current work aims to establish a hardware platform and numerical computation methods to reproduce dynamic muscle forces that can be applied to mechanical testing on in vitro specimens. Dynamic muscle loading is simulated through numerical computation, and the inputs of the platform will be derived. Then, the accuracy and robustness of the platform will be evaluated through actual muscle loading tests in vitro. The tests were run on three muscles (gastrocnemius lateralis, the rectus femoris, and the semitendinosus) around the knee joint and the results showed that the platform can accurately reproduce the magnitude of muscle strength (errors range from −6.2% to 1.81%) and changing pattern (goodness-of-fit range coefficient ranges from 0.00 to 0.06) of target muscle forces. The robustness of the platform is mainly manifested in that the platform can still accurately reproduce muscle force after changing the hardware combination. Additionally, the standard deviation of repeated test results is very small (standard ranges of hardware combination 1: 0.34 N~2.79 N vs. hardware combination 2: 0.68 N~2.93 N). Thus, the platform can stably and accurately reproduce muscle forces in vitro, and it has great potential to be applied in the future musculoskeletal loading system.
- 25 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1006
Open AccessDevelopment and Validation of a Novel In Vitro Joint Testing System for Reproduction of In Vivo Dynamic Muscle Force
In vitro biomechanical experiments utilizing cadaveric specimens are one of the most effective methods for rehearsing surgical procedures, testing implants, and guiding postoperative rehabilitation. Applying dynamic physiological muscle force to the specimens is a challenge to reconstructing the environment of bionic mechanics in vivo, which is often ignored in the in vitro experiment. The current work aims to establish a hardware platform and numerical computation methods to reproduce dynamic muscle forces that can be applied to mechanical testing on in vitro specimens. Dynamic muscle loading is simulated through numerical computation, and the inputs of the platform will be derived. Then, the accuracy and robustness of the platform will be evaluated through actual muscle loading tests in vitro. The tests were run on three muscles (gastrocnemius lateralis, the rectus femoris, and the semitendinosus) around the knee joint and the results showed that the platform can accurately reproduce the magnitude of muscle strength (errors range from −6.2% to 1.81%) and changing pattern (goodness-of-fit range coefficient ranges from 0.00 to 0.06) of target muscle forces. The robustness of the platform is mainly manifested in that the platform can still accurately reproduce muscle force after changing the hardware combination. Additionally, the standard deviation of repeated test results is very small (standard ranges of hardware combination 1: 0.34 N~2.79 N vs. hardware combination 2: 0.68 N~2.93 N). Thus, the platform can stably and accurately reproduce muscle forces in vitro, and it has great potential to be applied in the future musculoskeletal loading system.