KCKushan Choksi

Kushan Choksi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kushan Choksi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Review and Comparison of Medium/High Voltage Wide-Bandgap Devices Applications in Wind Energy Conversion Systems

    by Yuxuan Wu, Yang Li, Deepi Singh, Kushan Choksi, Mustafeez- Ul- Hassan, Fang Luo, David Torrey

    This paper presents a comprehensive review of Medium Voltage (MV) Wind Energy Conversion Systems (WECS) with the integration of Wide-bandgap (WBG) semiconductor devices. With the growing demand for high-power offshore wind applications and the limitations of conventional Si-based power electronics, WBG devices offer significant advantages, including higher efficiency, reduced filter size, improved dynamic response, and enhanced thermal performance. This review evaluates MV WECS from system architecture to turbine converter design, highlighting how MV WBG devices enable advanced electrical architectures such as DC collection systems and Solid-State Transformers (SSTs). Additionally, the impact of ripple currents on generator losses—particularly in superconducting generators—is investigated. Simulation-based comparisons of various converter topologies with silicon- (Si) and silicon-carbide- (SiC) based devices validate the improvements in power quality and efficiency enabled by WBG technology. The review addresses the current research gap in MV WBG applications for WECS and provides insights into future trends and design considerations for high-efficiency, high-power WECS.

  • Modeling and Optimization of Near-Field Coupling Between Power Loop and Gate Drive in High-Density Bidirectional Converters

    by Yuxuan Wu, Kushan Choksi, Samuel Defaz, Abdul Basit Mirza, Fang Luo

    With the advent of wide-bandgap devices, power converters are achieving higher performance switching capabilities. As a result, manufacturers are increasingly focused on reducing the complexity of power converters and enhancing the production and assembly process by transitioning from modular to highly integrated designs, which are high-density bidirectional converters (HDBCs). As a result, near-field (NF) coupling is becoming a concern for stable operation in HDBCs. Optimization for the power loop and gate drive (GD) can be achieved through computational electromagnetics tools and circuit simulators, allowing for a detailed visualization of NF distributions. In addition, the GD impedance can be fine-tuned by optimizing the gate-source trace layout, while near-electric field coupling must be considered when implementing a shielding layer between the GD and high $\text{d}\mathbf {v}/\text{d}\mathbf {t}$ nodes. This work presents a workflow for GD and power loop NF coupling modeling and optimization in HDBCs, aimed at mitigating issues such as mistriggering of switching devices and electromagnetic interference concerns in low-voltage systems.


  • Multitime-Scale Digital Twin for Health and Fault Monitoring of a Boost Converter

    by Kushan Choksi, Masayuki Hijikata, Abdul Basit Mirza, Austin Zhou, Deepi Singh, Fang Luo

    Component degradation in power electronic converters poses a serious threat to system reliability. This degradation is linked to the health of individual components, potentially causing a butterfly effect that leads to reduced lifespan or faults in the power electronic system. This article presents a multi-time scale digital twin-based condition monitoring approach, featuring enhanced pseudo-heuristic health monitoring and pattern recognition-based fault monitoring, demonstrated in a boost converter application. The proposed concept utilizes the application of condition monitoring using top switch/diode voltage and inductor current for improved health estimation and faster fault detection. It should be noted that the degradation of device on resistance Rds,on and inductor series resistance RL similarly impacts inductor current and output voltage, making it challenging to monitor individual degradation. This paper comprehensively analyzes different types of faults and experimentally validates on a low-voltage SiC-based converter prototype. The proposed fault monitoring algorithm is independent of operating conditions and sensor integrity issues, as the significant pulsating voltages across the device provide patterns with enough tolerance for robust fault monitoring, thereby enhancing fault detection compared to the inductor/switch current threshold-based fault detection algorithm in the existing literature. Lastly, the paper delves into design consideration and challenges related to adding a voltage sensor across the top device and associated control complexities.


  • Investigation of Reflected Wave Phenomenon in SiC-Based Two-Level Split-Phase Inverter-Fed Motor Drives

    by Abdul Basit Mirza, Kushan Choksi, Sama Salehi Vala, Ali Anwar, Fang Luo

    Fast switching speed of silicon carbide (SiC) exacerbates reflected wave phenomenon (RWP) in two-level (2L) voltage source inverter (VSI)-based motor drives, causing motor side overvoltage and drive side overcurrent. The 2L split-phase (2L-SP) topology shows prospects of alleviating RWP due to its lower output $\text{d}v/\text{d}t$ facilitated by split-inductors which also serve as an output reactor. This article explores RWP in a 2L-SP-based motor drive and compares it with the 2L with an output reactor, denoted as 2L-LF. For the study, a 2L, 2L-LF, and 2L-SP configurable 18-kVA SiC-based prototype is developed and interfaced to an emulated motor load through a bundled shielded cable. At first, simplified lumped differential mode (DM) equivalent circuits are derived for modeling RWP transients in 2L-LF and 2L-SP drives. Subsequently, RWP is investigated through double pulse tests (DPT) for various cable lengths, reactor (2L-LF), and split inductor (2L-SP) values. Results show that 2L-SP exhibits lower RWP for longer cables, achieving up to 68% and 73% reduction in overvoltage and overcurrent amplitudes for an 8 m cable. An anomalous rising overvoltage pattern for short cables is observed for both drive configurations and analyzed using proposed DM equivalent circuits. Further, from a switching performance standpoint, split-inductors in 2L-SP decouple load and complementary cell's parasitics from the device during switching, achieving 17% lower switching loss than 2L-LF. Following the DPTs, continuous three-phase tests are performed for 8 m cable for both drive configurations. The 2L-SP drive achieves up to 60% and 74% reduction in overvoltage and overcurrent amplitudes than 2L-LF. Overall, 2L-SP outperforms 2L-LF in mitigating RWP in SiC-based 2L VSI motor drives.


  • Simplified Analytical Modeling of Reflected Wave Transients in Cable-Connected VSI-Based Motor Drives With Output Reactor

    by Abdul Basit Mirza, Sama Salehi Vala, Kushan Choksi, Fang Luo

    This letter proposes a simplified lumped analytical model to investigate reflected wave phenomenon (RWP) in a two-level voltage source inverter-based motor drive with an output reactor. RWP causes motor side overvoltage and drive side overcurrent. The output reactor at the drive side is a preferred RWP mitigation approach for its simplicity. However, existing RWP modeling approaches, for reactor design purposes, rely on complex cable and motor circuit models, requiring time-consuming simulations or are oversimplified, neglecting motor impedance and drive's output slew rate $\text{d}v/\text{d}t$ . To address this, the proposed model incorporates a condensed motor model and a ramp edge source for the drive output. It is solved to obtain closed-form expressions for estimating the slew rate of overvoltage and overcurrent transients and their respective peak values. Finally, the derived expressions are validated through double pulse tests on a silicon carbide-based hardware prototype for different cable lengths and reactor values.


  • Investigation of Reflected Wave Phenomenon in WBG-Driven Aircraft Power System

    by Kushan Choksi, Masayuki Hijikata, Yuxuan Wu, Mustafeez- Ul- Hassan, Deepi Singh, Abdul Basit Mirza, Bo Liu, Xin Wu, Fang Luo

    The rise of wide band gap (WBG) technologies has led to rise in the electrification of aircraft systems for a sustainable future with lower costs encouraged by favorable governmental policies. While WBG is efficient, it introduces over-voltages due to impedance mismatches, risking motor and cable failure. Moreover, this surge in aircraft electrification stresses electrical wiring interconnect systems (EWIS). This research focuses on the length and frequency-extendable modeling of aircraft cables. The proposed cable model includes the characterization of high-frequency (HF) phenomena such as skin and proximity effect, mutual coupling, and common-mode (CM) parasitic elements. CM parasitic are crucial due to inconsistencies in grounding/shielding approaches, and cable layouts. Furthermore, with the advent of protection and monitoring requirements at the ends of cables serving as ’unavoidable additional impedance network’ (lead wires), this paper studies the impact of infrastructural parasitic and the added impedance network on reflected wave modeling. Notably, this paper provides an improved average approximation of the load overvoltage incorporating the impact of lead wires, varying d v /d t of WBG devices, and cable length. Lastly, the study concludes with a rigorous combination of experimentation and simulations, ensuring a comprehensive comparative analysis to validate the effectiveness of the proposed modeling approach.


  • Converter-Level Packaging and Optimization for a SiC-Based Grid-Interface Converter Using Discrete Devices

    by Abdul Basit Mirza, Kushan Choksi, Austin Zhou, Sama Salehi Vala, Fang Luo

    Grid-integration of renewables through power electronic Grid-Interface Converters (GICs) is essential for achieving a sustainable grid. This mission involves developing compact, efficient converters with standardized interfaces to minimize redundancy. In line with this objective, this paper presents an electro-mechanical-thermal design and packaging of a two-stage SiC-based 75 kVA GIC using TO-247 discrete devices with two times lower cost-to-power ratio than power modules. The power stage is 3-D packaged on a cylindrical-hole-based three-face utilized heat sink to achieve 5.5 kW/L power density, including passive components. For the DC-AC stage, Two-Level Split-Phase topology (2L-SP) is employed, owing to its lower switching loss and output d v /d t and increased cross-talk immunity compared with simple Two-Level (2L) topology. An equivalent switching transition circuit is derived for optimal sizing of split inductors in 2L-SP. Further, for device interconnection, an optimized PCB layout with flux cancellation and minimum board parasitic capacitance is developed for optimal device switching with minimum voltage overshoot. Moreover, for magnetics, split-direct winding technique is employed to achieve minimum winding capacitance. Lastly, the developed GIC is systematically tested at rated system voltage with an RL load at 10 kVA.


  • Cable and Motor Winding Impedance Interactions in Motor Drive Systems and its Impact on HF Overvoltages

    by Yalda Azadeh, Kushan Choksi, Abdul Basit Mirza, Xiaolong Zhang, Yuxuan Wu, Fang Luo, Kiruba S. Haran

    Voltage stress across motor winding is critical for insulation health when its series resonance frequencies, which have the least impedances, known as antiresonances, coincide with overvoltage (OV) resonance frequencies across it, named as antiresonance phenomenon (ARP). First, this article discloses that the OV resonance frequencies across motor winding (load) can be represented by the combination impedance of cable plus load. Second, it investigates the interactions between the cable and load impedances in different layouts and examines their impact on the ARP. Then, it discloses the sensitivity of ARP versus cable and load impedance parameters. Lastly, the ARP's correlation with these parameters establishes a safe operation area as a motor drive system design guideline. Contrary to the general belief that systems using short cable or integrated systems have less insulation damage, this study shows that the OV stress in these systems can be critical. This article offers a simplified methodology to optimize the reliability of the drive system and mitigate the ARP. By using this approach, the article suggests that the time-consuming iterative design of dV/dt filters or overdesign of insulation can be eliminated. The practical test and modeled system are conducted to validate the approach.


  • Self-Evolving Digital Twin-Based Online Health Monitoring of Multiphase Boost Converters

    by Kushan Choksi, Abdul Basit Mirza, Austin Zhou, Deepi Singh, Masayuki Hijikata, Fang Luo

    Component degradation in power electronic converters severely threatens the system's reliability. These components degrade over time due to switching action, and this phenomenon is further aggravated with wide band gap devices. For ensuring system reliability and accurate degraded component identification, the development of a real-time noninvasive health monitoring mechanism is desired. This article develops and validates a real-time digital twin (DT)-based condition monitoring for multiphase interleaved boost converters. The DT model is based on an actual state-space modeling approach which is solved numerically using Runge–Kutta fourth to mimic the physical system. Then, the output signals from physical hardware and the DT model are compared to find the least squared error-based multiobjective optimization problem. A metaheuristic approach like particle swarm optimization and genetic algorithm is used to estimate the health of components of the converter. The proposed methodology is extendable to different inductor coupling strategies under continuous-conduction-mode and discontinuous-conduction-mode operations. The idea is to generalize the DT modeling concept for condition monitoring. Moreover, the article proposes decoupling and hybrid approaches to improve estimation accuracy by 9.4% and reduce embedded computational requirements by 22%, respectively. A 75 kW, 60-kHz SiC IBC hardware prototype is built and tested for concept validation. Notably, the challenges and impact of various sensing integrity errors encountered during condition monitoring are also discussed. Finally, the article discusses novel pre and postprocessing steps for improving estimation accuracy and robustness in the case of control, sensing, and operating condition variability.