Sofía Vergara
Sofía Vergara has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christian Rueda
Universidad Internacional del Ecuador UIDE, Facultad de Ciencias Técnicas. Quito, Ecuador
2 shared publications - Guillermo Mosquera
Universidad Internacional del Ecuador UIDE
2 shared publications - Vladimir Bonilla
Universidad Internacional del Ecuador (UIDE)
2 shared publications - Luis Miguel Sánchez Muyulema
Universidad UTE
1 shared publication - Marcelo Moya
Facultad de Ingenierías Digitales y Tecnologías Emergentes, Universidad Internacional del Ecuador UIDE, Quito 170411, Ecuador
1 shared publication
Latest Publications
- Open Access
- 28 March 2025
- Published by Salud, Ciencia y Tecnologia in Data and Metadata
- Vol. 4, 759
Design and Comparison of Controllers for a Robotic Transfemoral Prosthesis
This study investigates the performance of four control strategies—Proportional-Derivative (PD), Feedforward-Feedback PD (FF-FB PD), Linear Quadratic Regulator (LQR), and Feedforward-Feedback LQR (FF-FB LQR)—implemented on a robotic transfemoral prosthesis. The performance metrics, including overshoot, settling time, trajectory tracking accuracy, and torque requirements, were evaluated using simulation models. The results indicate that the FF-FB LQR controller demonstrated superior performance, achieving the lowest overshoot (4.98%) and near-zero trajectory tracking error. All controllers required approximately 8.6 Nm of torque, suggesting consistent energy requirements across strategies despite their performance differences. The LQR controller exhibited the best stability, minimizing overshoot and improving overall system response. These findings highlight the advantages of feedforward-feedback control strategies, particularly the FF-FB LQR, for controlling robotic transfemoral prostheses with enhanced stability and accuracy.
- 28 March 2025
- Published by Salud, Ciencia y Tecnologia in Data and Metadata
- Vol. 4, 759
Open AccessDesign and Comparison of Controllers for a Robotic Transfemoral Prosthesis
This study investigates the performance of four control strategies—Proportional-Derivative (PD), Feedforward-Feedback PD (FF-FB PD), Linear Quadratic Regulator (LQR), and Feedforward-Feedback LQR (FF-FB LQR)—implemented on a robotic transfemoral prosthesis. The performance metrics, including overshoot, settling time, trajectory tracking accuracy, and torque requirements, were evaluated using simulation models. The results indicate that the FF-FB LQR controller demonstrated superior performance, achieving the lowest overshoot (4.98%) and near-zero trajectory tracking error. All controllers required approximately 8.6 Nm of torque, suggesting consistent energy requirements across strategies despite their performance differences. The LQR controller exhibited the best stability, minimizing overshoot and improving overall system response. These findings highlight the advantages of feedforward-feedback control strategies, particularly the FF-FB LQR, for controlling robotic transfemoral prostheses with enhanced stability and accuracy.
- Open Access
- 3 March 2023
- Published by Universidad de Bogota Jorge Tadeo Lozano in Revista Mutis
- Vol. 13 (2) , 1-12
Diseño de un sistema de control de prótesis transfemoral basado en redes neuronales
With this project, the control of a transfemoral prosthesis was developed by means of a neural network. The mechatronics methodology based on the V-model was used. This document first presents an analysis of the situation of physical-motor disabilities in Ecuador and reviews some prosthesis designs to propose a local solution. The requirements that were proposed, were used as inputs for the development of the conceptual and specific design. The data acquisition system was established to perform the measurements of muscle activity and position by means of an accelerometer. A neural network consisting of a 3-input layer with 12 neurons in the hidden layer and one neuron in the output layer was trained. The output of the network corresponds to the position that the prosthesis must reach, and the developed system has a 20% error in the prediction of the flexion and extension movements of the leg. En el presente proyecto se desarrolló el control de una prótesis transfemoral por medio de una red neuronal. Se utilizó la metodología mecatrónica basada en el modelo en V. Primero se presenta un análisis a la situación de discapacidades físico-motoras de Ecuador y se revisan algunos diseños de prótesis para proponer una solución local. Se plantearon requerimientos que se usaron como insumos para el desarrollo del diseño conceptual y específico. Se estableció el sistema de adquisición de datos para realizar las mediciones de actividad muscular y posición por medio de un acelerómetro. Se entrenó una red neuronal formada de una capa de 3 entradas con 12 neuronas en la capa oculta y una neurona en la capa de salida. La salida de la red corresponde a la posición a la que debe llegar la prótesis, y el sistema desarrollado tiene un error del 20% en la predicción de los movimientos de flexión y extensión de la pierna.
- 3 March 2023
- Published by Universidad de Bogota Jorge Tadeo Lozano in Revista Mutis
- Vol. 13 (2) , 1-12
Open AccessDiseño de un sistema de control de prótesis transfemoral basado en redes neuronales
With this project, the control of a transfemoral prosthesis was developed by means of a neural network. The mechatronics methodology based on the V-model was used. This document first presents an analysis of the situation of physical-motor disabilities in Ecuador and reviews some prosthesis designs to propose a local solution. The requirements that were proposed, were used as inputs for the development of the conceptual and specific design. The data acquisition system was established to perform the measurements of muscle activity and position by means of an accelerometer. A neural network consisting of a 3-input layer with 12 neurons in the hidden layer and one neuron in the output layer was trained. The output of the network corresponds to the position that the prosthesis must reach, and the developed system has a 20% error in the prediction of the flexion and extension movements of the leg. En el presente proyecto se desarrolló el control de una prótesis transfemoral por medio de una red neuronal. Se utilizó la metodología mecatrónica basada en el modelo en V. Primero se presenta un análisis a la situación de discapacidades físico-motoras de Ecuador y se revisan algunos diseños de prótesis para proponer una solución local. Se plantearon requerimientos que se usaron como insumos para el desarrollo del diseño conceptual y específico. Se estableció el sistema de adquisición de datos para realizar las mediciones de actividad muscular y posición por medio de un acelerómetro. Se entrenó una red neuronal formada de una capa de 3 entradas con 12 neuronas en la capa oculta y una neurona en la capa de salida. La salida de la red corresponde a la posición a la que debe llegar la prótesis, y el sistema desarrollado tiene un error del 20% en la predicción de los movimientos de flexión y extensión de la pierna.