GMGuillermo Mosquera

Guillermo Mosquera

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guillermo Mosquera has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Classification of Weld Bead Defects Using Convolutional Neural Networks

    by Alexis Carrillo, Guillermo Mosquera Canchingre, Andrea Pilco, Michael Guerra

    Welding plays a critical role in industrial manufacturing, defects such as cracks, porosity, and incomplete fusion compromise structural integrity. Traditional inspection techniques, including manual assessment and non-destructive testing (NDT), are labor-intensive and prone to human error. This study presents a comparative study on the visual classification of weld bead defects in Shielded Metal Arc Welding (SMAW) using Convolutional Neural Networks (CNNs). The study used two image datasets: one with image preprocessing techniques applied (sharpening, adaptive contrast adjustment, and Gaussian smoothing), and another without any preprocessing. Both datasets were used to train and evaluate a CNN model under controlled laboratory conditions. The results demonstrate that preprocessing improves model performance, increasing accuracy from 91.66% (without filters) to 98.00% (with filters). A detailed comparison with related works highlights the contribution of this approach, which not only achieves competitive accuracy but also introduces a replicable methodology for dataset preparation and analysis.

  • Digital Twin for a Semiautomatic Carbonated Water Packaging Machine

    by Martín Puente, Marcelo Moya, Guillermo Mosquera, Faruk Abedrabbo, Kleber Castro

  • Open Access

    Design and Comparison of Controllers for a Robotic Transfemoral Prosthesis

    by Guillermo Mosquera, Vladimir Bonilla, Sofía Vergara, Christian Rueda, Marcelo Moya

    This study investigates the performance of four control strategies—Proportional-Derivative (PD), Feedforward-Feedback PD (FF-FB PD), Linear Quadratic Regulator (LQR), and Feedforward-Feedback LQR (FF-FB LQR)—implemented on a robotic transfemoral prosthesis. The performance metrics, including overshoot, settling time, trajectory tracking accuracy, and torque requirements, were evaluated using simulation models. The results indicate that the FF-FB LQR controller demonstrated superior performance, achieving the lowest overshoot (4.98%) and near-zero trajectory tracking error. All controllers required approximately 8.6 Nm of torque, suggesting consistent energy requirements across strategies despite their performance differences. The LQR controller exhibited the best stability, minimizing overshoot and improving overall system response. These findings highlight the advantages of feedforward-feedback control strategies, particularly the FF-FB LQR, for controlling robotic transfemoral prostheses with enhanced stability and accuracy.


  • Cost-Effective Tension Testing System for Plastics Industries

    by Michael Guerra, Faruk Abedrabbo, Viviana Moya, Angélica Quito, Guillermo Mosquera, Juan Pablo Vásconez

  • Open Access

    Implementation of Industry 4.0 in metallurgical factories

    by Luz Tobar Subía, Cristian Tasiguano Pozo, Fernando Valencia, David Villarreal, Christian Vásquez, Guillermo Mosquera Canchingre

    This paper presents the preliminary results of a study on implementing Industry 4.0 in metallurgical factories. It showed that adopting Industry 4.0 technologies generates a productive environment characterized by real-time sensing, with high adaptability, flexibility, self-learning capacity, and fault tolerance. In the context of the Ecuadorian industry, particularly in micro, small, and medium-sized enterprises (MSMEs), there is limited integration of industrial technologies, both at the software and hardware levels. Additionally, many factories do not perceive the relevance of implementing solutions based on Industry 4.0 in key areas such as production, quality control, and maintenance. The study presents three case studies of metalworking factories that emerged as small locksmith workshops and analyzes the challenges related to incorporating new know-how in these industries. The findings concluded that Industry 4.0 has transformative potential for the value chain, facilitating the development of innovative products and services.


  • Open Access

    Application of Model-Based Design for Filtering sEMG Signals Using Wavelet Transform

    by Vladimir Bonilla Venegas, Guillermo Mosquera Canchingre, Miguel Sánchez Muyulema, Nelson Gutiérrez Suquillo, Jonnathan Ismael Chamba Cruz

    The aim of this study was the integration of model-based design and Wavelet transform techniques for filtering surface electromyography (sEMG) signals. In the first stage the noises and interferences that disturb sEMG signals were analyzed to implement a digital filter in a low-cost embedded system that filters these signals. It was shown that the noises and interferences are caused by various sources. Sources of interference and noise can be divided into internal and external. Internal noise is caused by the electrodes, EMG signals of other muscles, and noise associated with the functioning of other organs such as the heart or stomach. The external noises are due to the electrical environment, the most prominent of which is the direct interference of the power hum, produced by the incorrect grounding of other devices and electromotors. For the analysis of the digital filter, sEMG signals from the biceps muscle were used when the elbow joint was at rest and during flexion and extension movements. Signals from 10 participants who did not have any atrophies or pathologies in the muscle were considered for this stage. Denoising of sEMG signals was performed using different wavelets; the smallest error was observed when using the biorthogonal wavelet 3/5 of level 6 with the soft thresholding method. The wavelet filter was implemented using the V-model, and the Processor in The Loop (PIL) tests helped to determine the characteristics of the embedded system where the digital filter was implemented. The digital filter code was implemented on an ESP32 board due to its processing speed of 328 ms.

  • Open Access

    Design and Implementation of a Bottle Packing Machine

    by Sebastián Vásquez, Alexander Tirira, Marcelo Moya, Guillermo Mosquera

    The article presents an innovative prototype of a bottle packaging machine, framed in the context of industrial development and process automation. The system is designed based on requirements that allow addressing common challenges in small and medium-sized business environments. The proposal stands out for its efficiency and affordability. The system offers an economical alternative to expensive commercial production models. The implementation and testing of the system have shown 100 percent accuracy in counting and packaging bottles, leading to a reduction of operating costs. The results show that the prototype, which has the capacity to process 16 bottles per minute, through the development of a PID controller synchronizes the arrival time of the bottles in the unloading area. The development cycle of the mechatronic system is complemented by software that, through a communication application, generates the user interface and production statistics through a client-server architecture using the HTTP communication protocol. The system highlights a comprehensive solution, which has been developed, meeting the specific requirements of industrial automation in bottle packaging.

  • Open Access

    Diseño de un sistema de control de prótesis transfemoral basado en redes neuronales

    by Sofía Vergara, Guillermo Mosquera, Vladimir Bonilla, Miguel Sánchez, Christian Rueda

    With this project, the control of a transfemoral prosthesis was developed by means of a neural network. The mechatronics methodology based on the V-model was used. This document first presents an analysis of the situation of physical-motor disabilities in Ecuador and reviews some prosthesis designs to propose a local solution. The requirements that were proposed, were used as inputs for the development of the conceptual and specific design. The data acquisition system was established to perform the measurements of muscle activity and position by means of an accelerometer. A neural network consisting of a 3-input layer with 12 neurons in the hidden layer and one neuron in the output layer was trained. The output of the network corresponds to the position that the prosthesis must reach, and the developed system has a 20% error in the prediction of the flexion and extension movements of the leg. En el presente proyecto se desarrolló el control de una prótesis transfemoral por medio de una red neuronal. Se utilizó la metodología mecatrónica basada en el modelo en V. Primero se presenta un análisis a la situación de discapacidades físico-motoras de Ecuador y se revisan algunos diseños de prótesis para proponer una solución local. Se plantearon requerimientos que se usaron como insumos para el desarrollo del diseño conceptual y específico. Se estableció el sistema de adquisición de datos para realizar las mediciones de actividad muscular y posición por medio de un acelerómetro. Se entrenó una red neuronal formada de una capa de 3 entradas con 12 neuronas en la capa oculta y una neurona en la capa de salida. La salida de la red corresponde a la posición a la que debe llegar la prótesis, y el sistema desarrollado tiene un error del 20% en la predicción de los movimientos de flexión y extensión de la pierna.