LMLuis Miguel Sánchez Muyulema

Luis Miguel Sánchez Muyulema

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luis Miguel Sánchez Muyulema has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • GENERACIÓN DE ENERGÍA ELÉCTRICA MEDIANTE MICROTURBINAS HIDRÁULICAS

    by Nelson Ramiro Gutiérrez Suquillo, Luis Miguel Sánchez Muyulema, Jonnathan Ismael Chamba Cruz, Guillermo Raúl Tumalli Naranjo

  • Proyectos de Arduino y Robótica Aplicada

    by Luis Miguel Sánchez Muyulema, Jonnathan Ismael Chamba Cruz, Christiam Xavier Núñez Zavala, Nelson Ramiro Gutiérrez Suquillo

    Proyectos de Arduino y Robótica Aplicada presenta una ruta académica y práctica para el diseño, construcción, programación, validación y mejora de sistemas robóticos orientados al aprendizaje tecnológico y la robótica competitiva. La obra articula fundamentos de electrónica, sistemas embebidos, sensores, actuadores, arquitectura de software, comunicaciones y control automático mediante proyectos progresivos basados principalmente en Arduino y ESP32. El lector desarrolla competencias para integrar hardware y software, seleccionar componentes, calibrar sensores, controlar motores, registrar información y evaluar el desempeño mediante procedimientos experimentales documentados. Los proyectos abarcan seguridad eléctrica, telemetría, seguimiento de línea, visión artificial, odometría, navegación, control PID, lógica difusa, registro de datos, análisis con Python y aprendizaje automático aplicado a robots reales. Cada propuesta vincula fundamentos teóricos con materiales, diseño electrónico, programación, pruebas, interpretación de resultados, identificación de errores y actividades de aprendizaje, favoreciendo una formación basada en evidencia. Dirigido a estudiantes, docentes, clubes de robótica y equipos de competencia, el libro promueve pensamiento ingenieril, experimentación sistemática, trabajo interdisciplinario y toma de decisiones técnicas. Su enfoque progresivo permite transformar módulos independientes en plataformas robóticas integradas, confiables, mantenibles y técnicamente documentadas para aplicaciones educativas, investigativas y competitivas de creciente complejidad y con criterios de seguridad, innovación, análisis crítico y mejora continua.

  • Open Access

    Electrónica Digital: Sistemas de Numeración, Lógica Combinacional y Secuencial

    by Irene Tustón Torres, Christiam Xavier Núñez Zavala, Mónica Alexandra Carrión Cevallos, Luis Miguel Sánchez Muyulema

    Electrónica Digital: Sistemas de Numeración, Lógica Combinacional y Secuencial presenta una visión integral de los principios que sustentan el diseño y análisis de sistemas digitales contemporáneos, articulando fundamentos matemáticos, representación de la información y técnicas de implementación con rigor didáctico. El texto aborda los sistemas de numeración y sus conversiones con claridad operativa, integra la aritmética binaria y los complementos como herramientas formales, y desarrolla los códigos digitales empleados en la comunicación y el procesamiento de datos. La obra avanza hacia el álgebra de Boole, las funciones lógicas, las tablas de verdad y los métodos de simplificación, vinculándolos con compuertas y familias lógicas para una comprensión funcional del hardware. Posteriormente, el análisis combinacional se construye mediante sumadores, comparadores, codificadores, decodificadores, multiplexores y demultiplexores, fortaleciendo el razonamiento estructurado mediante ejemplos y actividades. El estudio de la lógica secuencial consolida señales de reloj, multivibradores, celdas binarias, flip-flops, diagramas de estado y máquinas secuenciales, con énfasis en sincronismo y comportamiento temporal. La propuesta didáctica combina teoría, práctica y autoevaluación, favoreciendo la aplicación en automatización, control y telecomunicaciones. Su enfoque progresivo y sistemático apoya la formación técnica y universitaria, promueve precisión conceptual y fomenta competencias para el diseño eficiente de soluciones digitales confiables.

  • Open Access

    Comparison of Two System Identification Approaches for a Four-Wheel Differential Robot Based on Velocity Command Execution

    by Diego Guffanti, Moisés Filiberto Mora Murillo, Marco Alejandro Hinojosa, Santiago Bustamante Sanchez, Javier Oswaldo Obregón Gutiérrez, Nelson Gutiérrez, Miguel Sánchez

    Precise modeling of differential drive robots is crucial for effective control and trajectory planning in autonomous systems. A comparative analysis of two modeling approaches for a four-wheel differential drive robot is presented in this paper. The first approach, named Motor-Based Model (MBM), identifies four transfer functions, one for each motor, while the second approach, named Simplified Model (SM), uses only two transfer functions, one for linear velocity and another for angular velocity. Both models were validated by comparing their predicted trajectories against real odometry data obtained from a SLAM system implemented on a differential-drive robot. This provided a practical assessment of each model’s accuracy and underscored the importance of model selection in control design and navigation tasks. The results showed that the Motor-Based Model (MBM) consistently outperformed the Simplified Model (SM) in terms of odometry accuracy, both in position and orientation. Across all trajectories, the average RMSE for position using MBM was 0.309 m, while the SM recorded a higher average RMSE of 0.414 m. Similarly, the maximum position error averaged 0.522 m for MBM and 0.710 m for SM, confirming that MBM is more accurate and consistent in position tracking. Regarding the results of orientation estimation, when averaged across all experiments, the MBM maintained a lower angular RMSE of 0.170 rad in contrast to SM, which achieves an RMSE of 0.239 rad. The maximum angular error was also higher for the MBM at 0.316 rad, compared to 0.447 rad for the SM. Moreover, the computational performance evaluation indicated that the SM consistently outperformed MBM, achieving a 30% reduction in simulation time and substantially lower memory usage. These results demonstrate the relationship between model complexity and accuracy and suggest that the motor-specific model is more appropriate for applications requiring precise mapping or localization, such as SLAM, while the simplified model may be suitable for simpler use cases with lower computational requirements, such as embedded systems with limited resources. This paper provides a practical evaluation of the accuracy and computational performance of two modeling approaches, highlighting the implications of model selection for the design of navigation tasks.


  • Open Access

    Optimization of Fault Prediction by A.I. in Industrial Equipment: analysis of the operating parameters of a Bench Grinder

    by Nelson Ramiro Gutiérrez Suquillo, Jonnathan Ismael Chamba Cruz, Luis Miguel Sánchez Muyulema, Christiam Xavier Núñez, Rafael Christian Franco Reina

    Predictive Maintenance (PM) plays a crucial role in maximizing efficiency and reducing costs associated with equipment and system maintenance in industrial companies. Recent advancements in Machine Learning (ML) have revolutionized PM by offering accurate and efficient fault prediction and maintenance planning capabilities. This research focuses on monitoring a bench grinder and observing sensors for temperature, current, angular velocity, and vibration under normal operating conditions. The objective is to predict failures based on specific variables related to the machine. To develop the system, a prototype bench was designed to subject the machine to several working scenarios, collecting real-time sensor data. Data clusters were generated for each sensor, collecting 3000 samples over 7 consecutive days without faults and another 7 days with modified bench grinder behavior. Sampling was done at a rate of 1 second. The performance of Decision Trees (DT), Support Vector Machines (SVM), Naive Bayes (NB), and K-Means + Neural Network (NN) algorithms was compared using the confusion matrix metrics. Each algorithm's performance was evaluated for RPM, current, temperature, and vibrations measures. The SVM algorithm showed the highest error for RPM with 43.5%. In contrast, all algorithms achieved minimal or zero errors for vibrations, indicating excellent performance. These findings demonstrate the potential of ML algorithms in PM for the bench grinder. The results highlight the importance of selecting appropriate algorithms for specific measurements, with vibrations exhibiting the least error across all algorithms and contributes to optimize maintenance activities in industrial settings.

  • Open Access

    Application of Model-Based Design for Filtering sEMG Signals Using Wavelet Transform

    by Vladimir Bonilla Venegas, Guillermo Mosquera Canchingre, Miguel Sánchez Muyulema, Nelson Gutiérrez Suquillo, Jonnathan Ismael Chamba Cruz

    The aim of this study was the integration of model-based design and Wavelet transform techniques for filtering surface electromyography (sEMG) signals. In the first stage the noises and interferences that disturb sEMG signals were analyzed to implement a digital filter in a low-cost embedded system that filters these signals. It was shown that the noises and interferences are caused by various sources. Sources of interference and noise can be divided into internal and external. Internal noise is caused by the electrodes, EMG signals of other muscles, and noise associated with the functioning of other organs such as the heart or stomach. The external noises are due to the electrical environment, the most prominent of which is the direct interference of the power hum, produced by the incorrect grounding of other devices and electromotors. For the analysis of the digital filter, sEMG signals from the biceps muscle were used when the elbow joint was at rest and during flexion and extension movements. Signals from 10 participants who did not have any atrophies or pathologies in the muscle were considered for this stage. Denoising of sEMG signals was performed using different wavelets; the smallest error was observed when using the biorthogonal wavelet 3/5 of level 6 with the soft thresholding method. The wavelet filter was implemented using the V-model, and the Processor in The Loop (PIL) tests helped to determine the characteristics of the embedded system where the digital filter was implemented. The digital filter code was implemented on an ESP32 board due to its processing speed of 328 ms.

  • Open Access

    Diseño de un sistema de control de prótesis transfemoral basado en redes neuronales

    by Sofía Vergara, Guillermo Mosquera, Vladimir Bonilla, Miguel Sánchez, Christian Rueda

    With this project, the control of a transfemoral prosthesis was developed by means of a neural network. The mechatronics methodology based on the V-model was used. This document first presents an analysis of the situation of physical-motor disabilities in Ecuador and reviews some prosthesis designs to propose a local solution. The requirements that were proposed, were used as inputs for the development of the conceptual and specific design. The data acquisition system was established to perform the measurements of muscle activity and position by means of an accelerometer. A neural network consisting of a 3-input layer with 12 neurons in the hidden layer and one neuron in the output layer was trained. The output of the network corresponds to the position that the prosthesis must reach, and the developed system has a 20% error in the prediction of the flexion and extension movements of the leg. En el presente proyecto se desarrolló el control de una prótesis transfemoral por medio de una red neuronal. Se utilizó la metodología mecatrónica basada en el modelo en V. Primero se presenta un análisis a la situación de discapacidades físico-motoras de Ecuador y se revisan algunos diseños de prótesis para proponer una solución local. Se plantearon requerimientos que se usaron como insumos para el desarrollo del diseño conceptual y específico. Se estableció el sistema de adquisición de datos para realizar las mediciones de actividad muscular y posición por medio de un acelerómetro. Se entrenó una red neuronal formada de una capa de 3 entradas con 12 neuronas en la capa oculta y una neurona en la capa de salida. La salida de la red corresponde a la posición a la que debe llegar la prótesis, y el sistema desarrollado tiene un error del 20% en la predicción de los movimientos de flexión y extensión de la pierna.