Dongseong Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dongseong Shin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Duckhyun Kim
Korea Atomic Energy Research Institute (KAERI), Daejeon, South Korea
1 shared publication - Inyong Kwon
Department of Radiological Science, Yonsei University, Wonju, South Korea
1 shared publication - Kevin Tsai
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
1 shared publication - Minuk Seung
Korea Atomic Energy Research Institute (KAERI), Daejeon, South Korea
1 shared publication - Troy Unruh
Idaho National Lab. (INL), Idaho Falls, ID (United States)
1 shared publication - Woo-Young Choi
Yonsei University
1 shared publication
Latest Publications
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
In-Core Neutron Detection System Using a Dual-Mode Self-Reset Preamplifier With the Micro-Pocket Fission Detector
This article presents the development of an in-core neutron detector readout system utilizing a charge-sensitive amplifier (CSA) with a self-reset technique, alongside data loggers, to measure the output of the CSA. Micro-pocket fission detectors (MPFDs) were developed as in-vessel neutron detectors having many advantages in terms of portability size, reproducibility of charge deposition, usability in high neutron flux, and capability of gamma-ray discrimination. The proposed readout system for MPFDs can be operated in a dual mode which consists of integration and single event modes. The integration mode can count the number of saturated preamplifier outputs in a high-radiation environment. On the other hand, the single event mode can directly measure the analog data induced by detectors. A novel approach to dead time compensation is also introduced using an active dead time control (ADTC) method. This article shows the reactor transient test results conducted at the Transient REActor Test (TREAT) reactor. The neutron flux of 7 × 10 15 n/cm 2 · s with the full-width half maximum (FWHM) of 126 ms at the reactor power of 2.1 GWth was measured. According to the reactor power of 5.1 GWth, the neutron flux, and FWHM were obtained as 1.24 × 10 16 n/cm 2 · s and 136 ms, respectively.
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
In-Core Neutron Detection System Using a Dual-Mode Self-Reset Preamplifier With the Micro-Pocket Fission Detector
This article presents the development of an in-core neutron detector readout system utilizing a charge-sensitive amplifier (CSA) with a self-reset technique, alongside data loggers, to measure the output of the CSA. Micro-pocket fission detectors (MPFDs) were developed as in-vessel neutron detectors having many advantages in terms of portability size, reproducibility of charge deposition, usability in high neutron flux, and capability of gamma-ray discrimination. The proposed readout system for MPFDs can be operated in a dual mode which consists of integration and single event modes. The integration mode can count the number of saturated preamplifier outputs in a high-radiation environment. On the other hand, the single event mode can directly measure the analog data induced by detectors. A novel approach to dead time compensation is also introduced using an active dead time control (ADTC) method. This article shows the reactor transient test results conducted at the Transient REActor Test (TREAT) reactor. The neutron flux of 7 × 10 15 n/cm 2 · s with the full-width half maximum (FWHM) of 126 ms at the reactor power of 2.1 GWth was measured. According to the reactor power of 5.1 GWth, the neutron flux, and FWHM were obtained as 1.24 × 10 16 n/cm 2 · s and 136 ms, respectively.