SSShota Shigekiyo

Shota Shigekiyo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shota Shigekiyo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Preoperative factors associated with long-distance walking ability one year after total hip arthroplasty: a prospective cohort study

    by Ken Tomonari, Yasuaki Tamaki, Takashi Saito, Motomu Kamada, Yuka Sugiyama, Megumi Yamada, Tomohiro Goto, Yasuyuki Omichi, Keizo Wada, Shota Shigekiyo, et al.

    Purpose This study aimed to identify preoperative predictors of the six-minute walk distance (6MWD) one year after primary unilateral total hip arthroplasty (THA). Methods This prospective cohort study included 152 women with hip osteoarthritis who underwent primary unilateral THA between April 2016 and June 2024. Preoperative assessments included age, body mass index (BMI), pain intensity (numerical rating scale), Timed Up and Go (TUG) test, 6MWD, hip abductor strength, range of motion (ROM) in flexion and extension at the hip, presence of contralateral hip osteoarthritis, and gait pattern (independent/cane-assisted). The primary outcome was 6MWD at one year postoperatively. Univariate and multiple linear regression analyses were performed to identify independent preoperative predictors of the 6MWD at one year postoperatively. Results All functional outcomes except BMI improved significantly at one year postoperatively. Multiple regression analysis identified age (β = − 2.8, p = 0.001), BMI (β = − 3.3, p = 0.049), preoperative 6MWD (β = 0.6, p = 0.001), and contralateral hip extension ROM (β = 2.8, p = 0.045) as independent predictors of 6MWD at one year postoperatively. Conclusions The 6MWD significantly improved one year after THA but not to the level observed in healthy individuals. Long-distance walking ability one year after THA is associated not only with systemic factors such as age, BMI, and preoperative endurance but also with contralateral hip extension ROM. The functional status of both lower limbs and global physical capacity should be considered when evaluating postoperative walking recovery.


  • Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode

    by Yasuaki Tamaki, Keizo Wada, Shota Shigekiyo, Yuto Sugimine, Ken Tomonari, Koichi Sairyo

    Purpose This study evaluated the accuracy of intraoperative leg length and femoral anteversion measurements obtained during total hip arthroplasty (THA) using the Mako robotic system with enhanced mode. Methods A total of 55 hips in four men and 51 women who underwent primary THA with the Mako system via an anterolateral approach were retrospectively evaluated. Intraoperative measurements of leg length and femoral anteversion displayed by the Mako enhanced mode were compared with postoperative CT-based measurements. Absolute errors and their distributions were calculated to assess the accuracy of intraoperative assessments. Results The mean absolute error was 2.3 ± 1.8 mm for postoperative leg length discrepancy and 2.9 ± 2.2° for stem anteversion. Of the 55 hips, 46 (83.6%) showed leg length errors within 3 mm and 51 (92.7%) within 5 mm. For stem anteversion, 48 hips (87.3%) were within 3° and all 55 hips (100%) were within 5°. Mako enhanced mode could not be completed in 10.7% of cases because of femoral array loosening or screw penetration into the medullary canal. Conclusion Mako enhanced mode demonstrated clinically acceptable accuracy for intraoperative measurement of leg length and femoral anteversion, contributing to precise femoral stem implantation in robotic-assisted THA.


  • Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study

    by Yasuyuki Omichi, Daisuke Hamada, Keizo Wada, Yasuaki Tamaki, Shota Shigekiyo, Koichi Sairyo

    The purpose of this study was to directly compare implant placement accuracy and postoperative limb alignment between robotic-assisted total knee arthroplasty and navigation-assisted total knee arthroplasty. This retrospective case–control study included a consecutive series of 182 knees (robotic-assisted group, n = 103 knees; navigation-assisted group, n = 79). An image-free handheld robotic system (NAVIO) or an image-free navigation system (Precision N) was used. Component and limb alignment were evaluated on three-dimensional computed tomography scans and full-length standing anterior–posterior radiographs. We compared the errors between the final intraoperative plan and the postoperative coronal and sagittal alignment of the components and the hip–knee–ankle angle between the two groups. The orientation of the femoral and tibial components in the coronal plane were more accurate in the robotic-assisted group than in the navigation-assisted group (p < 0.05). There was no significant difference in the orientation of the femoral and tibial component in the sagittal plane between the two groups. There were fewer outliers in the tibial coronal plane in the robotic-assisted group (p < 0.05). There was also no significant difference in the frequency of outlying values for coronal or sagittal alignment of the femoral component or sagittal alignment of the tibial component or the hip–knee–ankle angle between the two groups. Robotic-assisted total knee arthroplasty using a handheld image-free system improved component alignment in the coronal plane compared with total knee arthroplasty using an image-free navigation system. Robotic surgery helps surgeons to achieve personalised alignment that may result in better clinical outcomes.